  1. No about everyone has forgotten to do that. If...

    No about everyone has forgotten to do that. If you have a problem address it otherwise you are ok.
  2. Replies
    14
    Views
    698

    A unit with no return? Doesn't sound good,...

    A unit with no return? Doesn't sound good, especially down there. Exactly how did the installer plan to dehumidify the space air? I've only seen it once and it was from a company known to do shady...
  3. Replies
    18
    Views
    1,792

    If the temp at the roll out switch isn't high...

    If the temp at the roll out switch isn't high enough to open it, change out the roll out switch. If your indoor blower runs like it should after heating stops place a piece of thread or anything...
  4. Replies
    26
    Views
    858

    If wired correctly a bad stat or w and y stat...

    If wired correctly a bad stat or w and y stat wires touching 24vac.
  5. Replies
    31
    Views
    991

    I would put it back as it was designed to...

    I would put it back as it was designed to operate. But that's just me. Some of my harder work came after I took the easy way too.
  6. Replies
    18
    Views
    632

    Thank You hvac69.

    Thank You hvac69.
  7. Replies
    18
    Views
    632

    I got you now. After removing the harness that...

    I got you now. After removing the harness that connects the J6 slot on the RTRM board to the J2 slot on the communication board I connect the J1 harness connector on the communication board to the...
  8. Replies
    18
    Views
    632

    The top left connection on the RTRM board is J6....

    The top left connection on the RTRM board is J6. Are you saying once I disconnect the harness that connects J6 on the RTRM board to J1 on the communication board i need to connect the wiring harness...
  9. Replies
    18
    Views
    632

    That's isn't possible. The harness on the...

    That's isn't possible. The harness on the communication board is connected to J1 it connects to the RTRM board at J6. If I remove the harness there will be nothing on J1 or J6. Check out my pic's....
  10. Replies
    18
    Views
    632

    635651635661

    635651635661
  11. Replies
    18
    Views
    632

    There's two I think they go to section J6. I'll...

    There's two I think they go to section J6. I'll look tomorrow if it stops raining and snap a couple of pic's.
  12. Replies
    18
    Views
    632

    HVAC69: There are two wiring harness's from the...

    HVAC69: There are two wiring harness's from the communication board to the RTRM board. Once I remove both wiring harness's that connect the two boards together which wiring harness connects to the...
  13. Replies
    18
    Views
    632

    I do not see how that is possible. If the...

    I do not see how that is possible. If the communication board remains connected then it will receive it's instructions to cycle on and off from Trane tracer summit software. I don't want that. I want...
  14. Replies
    18
    Views
    632

    The communication board mounted behind the RTRM...

    The communication board mounted behind the RTRM board has two wiring harness's connected to the RTRM board. I remove both connection at the RTRM board
    and connect my '3' wire Trane stat wires to...
  15. Replies
    18
    Views
    632

    I looked but never located what you stated. Do...

    I looked but never located what you stated. Do you have a link to it ? I imagine I would wire the three wire stat to the terminal strip and disconnect the wiring harness that connects the...
  16. Replies
    18
    Views
    632

    Taking off communications

    On a Trane Precedent RTU unit model YSC036E3RLA12000000000000. if I need to control the
    unit from the thermostat in the room instead of from communications, how do I do this?
    I suspect I unplug the...
  17. Thread: Cloudy ice

    by Ricky Dale
    Replies
    19
    Views
    1,842

    Flush your lines, have a good new filter and...

    Flush your lines, have a good new filter and clean your machine well. make sure your water isn't very cloudy before it enters the filter. A filter can only remove so much.
  18. Replies
    9
    Views
    1,831

    Possibly a short in the board from a poor design....

    Possibly a short in the board from a poor design. Unplug power to the board then apply power and see if it blows the fuse then. Or unplug all your control voltage leads and plug them in one at a time...
  19. Replies
    7
    Views
    989

    The few I've worked on the eye gets dirty and...

    The few I've worked on the eye gets dirty and can't send a beam across the top of the bin so it thinks the ice bin is full and blocking the beam.
  20. Replies
    3
    Views
    648

    Yes no luck on their site, I'll put the email...

    Yes no luck on their site, I'll put the email address in now. Thanks
  21. No. I know the Trane 1147 stat/sensor measures...

    No. I know the Trane 1147 stat/sensor measures the space temp in ohm's as well as the thumbwheel setting. What i'm asking is once the 517 board receives the ohm reading from the stat/sensor what...
  22. zone sensor temp/ 517 board conversion method.

    I have a question concerning Trane's 1147 zone temperature sensor. What's value reading does the sensor transmit to the 517 board for the 517 board to convert to a temperature so it can tell if the...
  23. Replies
    3
    Views
    648

    schmatic needed

    I get asked to work on an ice machine from time to time. it isn't my chosen interest but I would like know and clearly understand the sequence of operation
    of operation. We have Scotsman ice...
  24. Add the supply's. The garage isn't air tight. Co2...

    Add the supply's. The garage isn't air tight. Co2 monitors need to be in sleeping quarters. It fine to have them in every room but your fine here add them.
  25. Replies
    31
    Views
    3,038

    Coleman has an archives if you want to see if the...

    Coleman has an archives if you want to see if the model number is listed. It's just an old furnace and very reliable. We had a Coleman plant here Barber Coleman that made them here. Not in 1936 but...
  26. Sounds like you have a low ambient temp. and your...

    Sounds like you have a low ambient temp. and your cooling to a low temp. You may want to control the fan motor on the condensing coil so the refrigerant can condense, Set it to keep the condensing...
  27. Replies
    46
    Views
    4,620

    Contact the hvac board in your state and submit a...

    Contact the hvac board in your state and submit a complaint, Tell them the name of the roofer and what he did and that he will not correct it. They will come out and his bond will be used to correct...
  28. Replies
    40
    Views
    3,411

    When you attach you manifold gauges. The guage to...

    When you attach you manifold gauges. The guage to the right that reads you discharge pressure. Know which refrigerant you using r-22 or 410-a. The color of the refrigerant cylinder matches the color...
  29. Replies
    70
    Views
    11,400

    Goodman unit get a bad rap cause of the failure...

    Goodman unit get a bad rap cause of the failure of there equipment. Goodman unit keep a lot of people in business. I replaced an OD unit a little while back that was leaking at the bottom of the...
  30. A lot of people make this mistake. Never use the...

    A lot of people make this mistake. Never use the same color wire. always associate a wire color to a number. I like something I can remember like red white blue l1 l2 l3. Also for what it's worth...
  31. Replies
    14
    Views
    1,916

    As stated the limit/safety is tripping because...

    As stated the limit/safety is tripping because the chamber is getting to hot due to the indoor blower stopping or slowing enough allowing the heat to not be removed from the heating chamber,...
  32. Replies
    21
    Views
    2,044

    Ohm out the compressor and do an amp draw on it...

    Ohm out the compressor and do an amp draw on it when it starts. Its likely pulling to many amps cause the internal mechanical parts are beginning to seize. if it's old and it sounds like it is put a...
  33. Replies
    14
    Views
    1,477

    Follow your line voltage and control voltage from...

    Follow your line voltage and control voltage from the transformer. Someone has feed line voltage to the control side or they have shorted together. Trane secures there wiring to short.
  34. Replies
    40
    Views
    3,411

    if the unit tripped the breaker your first stage...

    if the unit tripped the breaker your first stage or both stages compressor's internal mechanical parts are seizing causing the unit to pull to many amps. Do an amp draw on startup and make sure the...
  35. Replies
    6
    Views
    637

    Thanks

    Thanks
  36. Replies
    6
    Views
    637

    Thanks i know that. Let me explain a little...

    Thanks i know that. Let me explain a little better about what were working with here, It's in a large public education environment. The thumbwheels are disabled. So the units cycle based on the...
  37. Replies
    6
    Views
    637

    The thumbwheel is disabled. the setpoints are set...

    The thumbwheel is disabled. the setpoints are set at 74 cooling and 71 for heating. My question is should the heating high limit be not be higher than the heating setpoint and the cooling low limit...
  38. Replies
    6
    Views
    637

    Trane Tracer high low limit question

    I have a question about the heating high limit and cooling low limit setpoints in Trane's tracer summit software. I read that the heating and cooling high and low limit setpoints 'CAP' the operating...
  39. RUNDAWG: I need your wisdom on a Trane actuator motor operation.

    Hello: Forum

    Rundawg, I have a couple questions on the operation of Trane actuator motors installed on a four pipe Trane fan coil unit.
    The actuator motor is...
  40. Replies
    0
    Views
    473

    cycling of fan coil blower motor

    From time to time I work on four pipe Trane fan coil units. They are controlled by Trane's tracer summit software. My question is what cycles the blower motor? The best I can figure is when the space...
  41. Thank you mason

    Thank you mason
  42. Replies
    8
    Views
    856

    The spark module is integrated into the board. ...

    The spark module is integrated into the board. Situation is understood my thanks to mason and a big thanks to rundawg.
  43. Order of safety checks Trane package gas.

    I've gotten conflicting information concerning the order in which the roll out and limit switch are checked to be closed when the there is a call for heat. one person stated the pressure, roll out...
  44. Replies
    8
    Views
    856

    Right you just jarred my brain safetys are...

    Right you just jarred my brain safetys are checked first. Thanks the ignition board is bad. I appreciate you.
  45. Replies
    8
    Views
    856

    My mistake yes the limit switch location. Once I...

    My mistake yes the limit switch location. Once I can confirm the limit switch location and that it is closed i'll know if the ignition board is faulty. The connection are made from the ignitor...
  46. Replies
    8
    Views
    856

    L

    L
  47. Replies
    8
    Views
    856

    L

    L
  48. Replies
    0
    Views
    417

    Trane XL 1600 package gas.

    I have a Trane XL 1600 to look at Monday. So far I've gotten the tech. on the job to confirm the inducer motor runs then the pressure switch closes and that's there is ctrl. voltage between w1 and...
  49. Replies
    8
    Views
    856

    limit rollout switch

    Hello: I have a call to go to on a Trane XL 1600 package gas. I'm short on time with this and would like to know exactly where the limit rollout switch is located. So far I've been told the inducer...
  50. Replies
    35
    Views
    5,686

    answers for heat pum question in Pa.

    A heat pump isn't recommended for you all up there unless it has a new 16 seer plus rating. You all get to cold of weather. make sure no water can drip on your coils and make sure you have drains...