01-16-2011, 02:14 PM
Thread: Burning up a Tstat??
by alexb- Replies
- 21
- Views
- 1,012
The one transformer in the A/C AH has a 3A fuse...
The one transformer in the A/C AH has a 3A fuse on the 24v side, and the transformer for the heat (installed in 1963) has no fuse on the 24v side, except for the 15A breaker on the Primary (120VAC)...
-
01-15-2011, 05:21 PM
Thread: Burning up a Tstat??
by alexb- Replies
- 21
- Views
- 1,012
FIXED! (I can't figure out why though, since it...
FIXED! (I can't figure out why though, since it worked perfectly for 4 years then stopped..) I re-wired the two zone-valves, transformer, and tstats according to a diagram I found on Taco's...
-
01-15-2011, 10:53 AM
Thread: Burning up a Tstat??
by alexb- Replies
- 21
- Views
- 1,012
OK - zone valve is rated for 24v and .9A. I...
OK - zone valve is rated for 24v and .9A. I compared upstairs zone-valve, which works perfectly.
Upstairs:
25.1v coming from transformer
dips to 21v when valve is opening, and is pulls .91A
... -
01-15-2011, 09:02 AM
Thread: Burning up a Tstat??
by alexb- Replies
- 21
- Views
- 1,012
'Fried' was my word I guess... What I've...
'Fried' was my word I guess... What I've diagnosed, is that when the Tstat closes its relay, which should send 24v to the zone-valve; there's no voltage. If I bridge R and W on the Tstat, voltage...
-
01-14-2011, 09:27 PM
Thread: Burning up a Tstat??
by alexb- Replies
- 21
- Views
- 1,012
Question: The "R" and "Rc" terminals on a Tstat...
Question: The "R" and "Rc" terminals on a Tstat are where the 'hot' line from the transformer connects. Rc is power-for-cooling. Does this mean "R" is the power for heat? Is this how a Tstat...
-
01-12-2011, 08:12 PM
Thread: Burning up a Tstat??
by alexb- Replies
- 21
- Views
- 1,012
the Tstat for downstairs is the one that died. ...
the Tstat for downstairs is the one that died. The upstairs Tstat is a Honeywell item from ~2002 (programable), but it doesn't go 'click' when a call for heat is made. This older Tstat is working...
-
01-12-2011, 01:49 PM
Thread: Burning up a Tstat??
by alexb- Replies
- 21
- Views
- 1,012
Fuse is still intact - I still see 28VAC at the...
Fuse is still intact - I still see 28VAC at the Tstat. I could swap the two zone valves to see if the problem follows the valve - but that's an expensive fix; because it fries an $80 Tstat.
For... -
01-12-2011, 12:33 PM
Thread: Burning up a Tstat??
by alexb- Replies
- 21
- Views
- 1,012
There's a 5A automotive-type fuse that powers the...
There's a 5A automotive-type fuse that powers the transformer. I think I left something out -- when the Tstat calls for heat, and closes the ckt for heating, the current routes thru one of those...
-
01-12-2011, 10:34 AM
Thread: Burning up a Tstat??
by alexb- Replies
- 21
- Views
- 1,012
Burning up a Tstat??
Can I get a professional opinion? I've been running just fine for 4 years with a Honeywell CT3500 Tstat. Just before Christmas my furnace stopped coming on. I traced this to the fact that the...
-
11-10-2010, 07:07 PM
- Replies
- 27
- Views
- 6,072
The old boiler (from pics of the nameplate) ...
The old boiler (from pics of the nameplate)
Federal Boiler model GFS-17. AGA input 175K AGA output 140K net output 123K The house was built in late '64, into '65. Boiler was working fine --... -
11-10-2010, 09:33 AM
- Replies
- 27
- Views
- 6,072
Question: That smaller horizontally-mounted...
Question: That smaller horizontally-mounted expansion tank has wording on it, that says it's for domestic hot water expansion. BUT: The tank is definitly on the cold-water input to the tank. Do...
-
11-09-2010, 12:30 PM
- Replies
- 27
- Views
- 6,072
Late-breaking news -- one of the union...
Late-breaking news -- one of the union connections right in front of where they cemented over the flue opening started leaking, and put a puddle on the floor, that was about 10feet in diameter. The...
-
11-07-2010, 08:57 AM
- Replies
- 27
- Views
- 6,072
mech_head said: C'mon, tell the truth, you knew...
mech_head said: C'mon, tell the truth, you knew going in you were going to post this here didn't you?
_______________________________
Oh yea, had the camera ready on this one..
The PVC... -
11-06-2010, 10:17 AM
- Replies
- 27
- Views
- 6,072
1965 Federal Boiler Replacement (Weil McLain)
Had to have the old 1965 Federal Boiler replaced.. (Baseboard & Domestic hot water) The only requirement was that it be direct-vented - we recently found out, from a recent PM, that the flue was...
-
11-06-2010, 10:10 AM
Thread: Picture U/L test
by alexb- Replies
- 7
- Views
- 1,227
Picture U/L test
Test to see if I can U/L a pic...
Before caption........
http://mysite.verizon.net/batsona/OldBoilerLeft.JPG
After caption........ -
02-19-2009, 01:47 PM
Thread: Experience with HydroSil elec baseboards...
by alexb- Replies
- 4
- Views
- 520
Thanks for the words of wisdom. I do recognize...
Thanks for the words of wisdom. I do recognize that the mfgr. is claiming to reduce the temp. swings by altering the current being fed to the element, which is apparently their claim-to-fame.
... -
02-18-2009, 07:28 PM
Thread: Experience with HydroSil elec baseboards...
by alexb- Replies
- 4
- Views
- 520
Experience with HydroSil elec baseboards...
I saw an ad recently for HydroSil elec. baseboard heaters. My house needs some supplemental heat, and HydroSil's "proportional" metering systems delivers just enough current to the element to...
-
09-25-2008, 12:07 PM
Thread: Difference between hot water heaters...
by alexb- Replies
- 15
- Views
- 1,064
I think I know the answer to this, but I'll ask...
I think I know the answer to this, but I'll ask anyway. Some heaters are called "power-vent", meaning they have the elec. motor & vent fan that sits on top. Does that type of setup *require* the...
-
09-24-2008, 09:11 AM
Thread: Difference between hot water heaters...
by alexb- Replies
- 15
- Views
- 1,064
My tank is a 40gal unit, with 38,000BTU intput,...
My tank is a 40gal unit, with 38,000BTU intput, and 70Gal 1st hour rating. Mfgr doesn't make this tank anymore, so I can't find any other stats on it, like the recovery rating (90F in an hr).
I... -
09-22-2008, 11:38 AM
Thread: Difference between hot water heaters...
by alexb- Replies
- 15
- Views
- 1,064
Good point on the showerhead - I have a vintage...
Good point on the showerhead - I have a vintage 1963 showerhead (gasp!) I've just been leery of replacing it, becuase if it twists in the wall, I'll have a leak on my hands, and my house is...
-
09-22-2008, 09:49 AM
Thread: Difference between hot water heaters...
by alexb- Replies
- 15
- Views
- 1,064
I'm not sure how a service company would be able...
I'm not sure how a service company would be able to fix the effects of a super bargain-basement water-heater. Since posting, I've read about two important stats: a.) First-hour-output and ...
-
09-21-2008, 09:57 PM
Thread: Difference between hot water heaters...
by alexb- Replies
- 15
- Views
- 1,064
Difference between hot water heaters...
In my old townhouse (built in 1998 actually) we had a 50gal hot water heater. Gas-fired, convection. We could take endless showers & have all the hot water we wanted. Now that I'm in a different...
-
03-16-2008, 10:22 AM
Thread: Charging via superheat...
by alexb- Replies
- 48
- Views
- 2,219
OP: I guess since that was a joke that meant...
OP: I guess since that was a joke that meant more to the people in the trade, I guess that's why I didn't get it. --Sorry!
I appreciate hearing all the techs say that doing a superheat &... -
03-14-2008, 08:20 PM
Thread: Charging via superheat...
by alexb- Replies
- 48
- Views
- 2,219
If BzzLine is going to be 'funny' when I'm...
If BzzLine is going to be 'funny' when I'm actually trying to be serious, then I guess this thread is closed. I'd posted frequently here in the past & had people respond to me appropriately. Until...
-
03-14-2008, 01:23 PM
Thread: Charging via superheat...
by alexb- Replies
- 48
- Views
- 2,219
I suspect improper charge from the beginning. ...
I suspect improper charge from the beginning. --Remember how I stated that the tech had the canister upside-down & tilted to one side & seemed startled when I came up behind him & asked him...