  1. Replies
    21
    Views
    1,012

    The one transformer in the A/C AH has a 3A fuse...

    The one transformer in the A/C AH has a 3A fuse on the 24v side, and the transformer for the heat (installed in 1963) has no fuse on the 24v side, except for the 15A breaker on the Primary (120VAC)...
  2. Replies
    21
    Views
    1,012

    FIXED! (I can't figure out why though, since it...

    FIXED! (I can't figure out why though, since it worked perfectly for 4 years then stopped..) I re-wired the two zone-valves, transformer, and tstats according to a diagram I found on Taco's...
  3. Replies
    21
    Views
    1,012

    OK - zone valve is rated for 24v and .9A. I...

    OK - zone valve is rated for 24v and .9A. I compared upstairs zone-valve, which works perfectly.

    Upstairs:
    25.1v coming from transformer
    dips to 21v when valve is opening, and is pulls .91A

    ...
  4. Replies
    21
    Views
    1,012

    'Fried' was my word I guess... What I've...

    'Fried' was my word I guess... What I've diagnosed, is that when the Tstat closes its relay, which should send 24v to the zone-valve; there's no voltage. If I bridge R and W on the Tstat, voltage...
  5. Replies
    21
    Views
    1,012

    Question: The "R" and "Rc" terminals on a Tstat...

    Question: The "R" and "Rc" terminals on a Tstat are where the 'hot' line from the transformer connects. Rc is power-for-cooling. Does this mean "R" is the power for heat? Is this how a Tstat...
  6. Replies
    21
    Views
    1,012

    the Tstat for downstairs is the one that died. ...

    the Tstat for downstairs is the one that died. The upstairs Tstat is a Honeywell item from ~2002 (programable), but it doesn't go 'click' when a call for heat is made. This older Tstat is working...
  7. Replies
    21
    Views
    1,012

    Fuse is still intact - I still see 28VAC at the...

    Fuse is still intact - I still see 28VAC at the Tstat. I could swap the two zone valves to see if the problem follows the valve - but that's an expensive fix; because it fries an $80 Tstat.

    For...
  8. Replies
    21
    Views
    1,012

    There's a 5A automotive-type fuse that powers the...

    There's a 5A automotive-type fuse that powers the transformer. I think I left something out -- when the Tstat calls for heat, and closes the ckt for heating, the current routes thru one of those...
  9. Replies
    21
    Views
    1,012

    Burning up a Tstat??

    Can I get a professional opinion? I've been running just fine for 4 years with a Honeywell CT3500 Tstat. Just before Christmas my furnace stopped coming on. I traced this to the fact that the...
  10. Replies
    27
    Views
    6,072

    The old boiler (from pics of the nameplate) ...

    The old boiler (from pics of the nameplate)

    Federal Boiler model GFS-17. AGA input 175K AGA output 140K net output 123K The house was built in late '64, into '65. Boiler was working fine --...
  11. Replies
    27
    Views
    6,072

    Question: That smaller horizontally-mounted...

    Question: That smaller horizontally-mounted expansion tank has wording on it, that says it's for domestic hot water expansion. BUT: The tank is definitly on the cold-water input to the tank. Do...
  12. Replies
    27
    Views
    6,072

    Late-breaking news -- one of the union...

    Late-breaking news -- one of the union connections right in front of where they cemented over the flue opening started leaking, and put a puddle on the floor, that was about 10feet in diameter. The...
  13. Replies
    27
    Views
    6,072

    mech_head said: C'mon, tell the truth, you knew...

    mech_head said: C'mon, tell the truth, you knew going in you were going to post this here didn't you?
    _______________________________

    Oh yea, had the camera ready on this one..

    The PVC...
  14. Replies
    27
    Views
    6,072

    1965 Federal Boiler Replacement (Weil McLain)

    Had to have the old 1965 Federal Boiler replaced.. (Baseboard & Domestic hot water) The only requirement was that it be direct-vented - we recently found out, from a recent PM, that the flue was...
  15. Thread: Picture U/L test

    by alexb
    Replies
    7
    Views
    1,227

    Picture U/L test

    Test to see if I can U/L a pic...


    Before caption........
    http://mysite.verizon.net/batsona/OldBoilerLeft.JPG
    After caption........
  16. Replies
    4
    Views
    520

    Thanks for the words of wisdom. I do recognize...

    Thanks for the words of wisdom. I do recognize that the mfgr. is claiming to reduce the temp. swings by altering the current being fed to the element, which is apparently their claim-to-fame.
    ...
  17. Replies
    4
    Views
    520

    Experience with HydroSil elec baseboards...

    I saw an ad recently for HydroSil elec. baseboard heaters. My house needs some supplemental heat, and HydroSil's "proportional" metering systems delivers just enough current to the element to...
  18. Replies
    15
    Views
    1,064

    I think I know the answer to this, but I'll ask...

    I think I know the answer to this, but I'll ask anyway. Some heaters are called "power-vent", meaning they have the elec. motor & vent fan that sits on top. Does that type of setup *require* the...
  19. Replies
    15
    Views
    1,064

    My tank is a 40gal unit, with 38,000BTU intput,...

    My tank is a 40gal unit, with 38,000BTU intput, and 70Gal 1st hour rating. Mfgr doesn't make this tank anymore, so I can't find any other stats on it, like the recovery rating (90F in an hr).

    I...
  20. Replies
    15
    Views
    1,064

    Good point on the showerhead - I have a vintage...

    Good point on the showerhead - I have a vintage 1963 showerhead (gasp!) I've just been leery of replacing it, becuase if it twists in the wall, I'll have a leak on my hands, and my house is...
  21. Replies
    15
    Views
    1,064

    I'm not sure how a service company would be able...

    I'm not sure how a service company would be able to fix the effects of a super bargain-basement water-heater. Since posting, I've read about two important stats: a.) First-hour-output and ...
  22. Replies
    15
    Views
    1,064

    Difference between hot water heaters...

    In my old townhouse (built in 1998 actually) we had a 50gal hot water heater. Gas-fired, convection. We could take endless showers & have all the hot water we wanted. Now that I'm in a different...
  23. Replies
    48
    Views
    2,219

    OP: I guess since that was a joke that meant...

    OP: I guess since that was a joke that meant more to the people in the trade, I guess that's why I didn't get it. --Sorry!

    I appreciate hearing all the techs say that doing a superheat &...
  24. Replies
    48
    Views
    2,219

    If BzzLine is going to be 'funny' when I'm...

    If BzzLine is going to be 'funny' when I'm actually trying to be serious, then I guess this thread is closed. I'd posted frequently here in the past & had people respond to me appropriately. Until...
  25. Replies
    48
    Views
    2,219

    I suspect improper charge from the beginning. ...

    I suspect improper charge from the beginning. --Remember how I stated that the tech had the canister upside-down & tilted to one side & seemed startled when I came up behind him & asked him...