Search:

Type: Posts; User: ETC1

Page 1 of 6 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    9
    Views
    526

    Semi critical charge. Short charge sub cooling...

    Semi critical charge. Short charge sub cooling valve throttles back too far at lower ambients. over charge causes floodback. Charge listed in manual. Many tanks I've worked on are installed...
  2. Replies
    9
    Views
    526

    Mueller Tank it is a subcooling valve

    Mueller Tank it is a subcooling valve
  3. Replies
    21
    Views
    1,090

    I own 2. Run about 1200 miles a week in season...

    I own 2. Run about 1200 miles a week in season with each, First summer with both so far so good. If these hold up as well as the 2010 model they will pay for them selves in operating savings. Maybe...
  4. Replies
    28
    Views
    1,068

    Gotta laugh I would advise letting someone else...

    Gotta laugh I would advise letting someone else be the butcher and finding work that allows you to make an honest profit. While showing you are not a moron that does sh-t work.
  5. Many of todays tools didn't exist when I started...

    Many of todays tools didn't exist when I started out. Many of the new tools are great improvements but many are security blankets. Tools don't make good mechanics. Knowledge makes good mechanics. I...
  6. Replies
    24
    Views
    1,664

    is it really copper or is it cuppernickle

    is it really copper or is it cuppernickle
  7. Replies
    30
    Views
    1,622

    First I love open compressors. When I started in...

    First I love open compressors. When I started in refrigeration most hermetics were on domestic refrigerators and small equipment. I was always told they were developed to make the cap tube feasible....
  8. Replies
    13
    Views
    1,119

    9w cw 115v Supco 671 Other 50 or so in shop or...

    9w cw 115v Supco 671 Other 50 or so in shop or at wholesalers will take special motors with me too job if I'm at shop and know what I might use. Truck weight is cost shop wear is a cost. Load...
  9. Replies
    16
    Views
    962

    I was taught receiver size with the receiver...

    I was taught receiver size with the receiver outlet closed and system pumped down to 0 psi the receiver should not exceed 80% full. Changing undersized receivers is not required as a second receiver...
  10. Replies
    27
    Views
    1,964

    I started my business in rural NY in 1979 by...

    I started my business in rural NY in 1979 by going to potential customers introducing myself and giving them my card. I gave them a brief summary of services I offered. I told them if they were...
  11. Replies
    10
    Views
    832

    Pressure is limited by pressure rating of system,...

    Pressure is limited by pressure rating of system, old R12 hermetics were rated at 150#
  12. Replies
    28
    Views
    2,202

    I don't find breakers by shorting. I've located...

    I don't find breakers by shorting. I've located too many 14 wires attached to 60 or 80 Amp three phase breakers with no other wires think of the fire hazard in an old building with old over fused...
  13. Thread: Milk bulk tank

    by ETC1
    Replies
    10
    Views
    1,659

    What part of thermostat is failing if it is the...

    What part of thermostat is failing if it is the points it is possible that it is a DC control circuit requiring snap action points to avoid burnout.
  14. Due to lack of reciever capacity clearing the ...

    Due to lack of reciever capacity clearing the sightglass before boxes are at temp will back liquid up in the condensor as the expansion valves throttle back. This is the most likley cause of...
  15. Static coils require a large amount of...

    Static coils require a large amount of refrigerant. Most non-factory installations have undersized recievers.These coils can run as low as 5degrees. Allow boxes too pull temperature then check...
  16. Thread: Opinion

    by ETC1
    Replies
    11
    Views
    917

    Try 1 thermostat and a time delay on solenoid of...

    Try 1 thermostat and a time delay on solenoid of unit #2. Lead lag in my experience assures that both compressors wear out equally. I don't seethis as an advantage.
  17. Replies
    7
    Views
    522

    Freezer is atleast 20 years old I believe Raetone...

    Freezer is atleast 20 years old I believe Raetone is gone for atleast as long. Before putting money in box check for availability of other parts. Its hard to explain to a customer you can't get door...
  18. Replies
    20
    Views
    2,045

    Filling the reciever will make for interesting...

    Filling the reciever will make for interesting start up. Remove reciever and install cap tube drier or some other access for highside. In the 80's I serviced an ice bank bulk tank with captubes and...
  19. Replies
    32
    Views
    1,796

    in rural America Smart phones are an expensive...

    in rural America Smart phones are an expensive decoration. First you need cell reception then it's nice If most of the population is not on dial up if they even have a computer.
  20. Thread: tubing bender

    by ETC1
    Replies
    20
    Views
    1,810

    The only problem with a ratchet bender is it...

    The only problem with a ratchet bender is it doesn't allow bends greater than 90 degrees. I use offset bends entering penetration.and in corners. I also do a lot of piping inside units requiring...
  21. Replies
    7
    Views
    609

    A solenoid on a scotsman flaker would be an added...

    A solenoid on a scotsman flaker would be an added cost that would add extra service and unnecesary electrical consumption. Float valves are a proven system. They are used in toilets, cooling towers...
  22. Replies
    7
    Views
    609

    The float valve shut stopping the water flow. If...

    The float valve shut stopping the water flow. If it doesn't replace the valve
  23. Replies
    7
    Views
    609

    Flakers require a gonstant water level. They make...

    Flakers require a gonstant water level. They make ice continuously therefore using water continuously. A solenoid valve would cause problems not a solution.
  24. Replies
    14
    Views
    1,758

    Saw these at Chillventa in Germany in 2010. Was...

    Saw these at Chillventa in Germany in 2010. Was told they would be in the states soon. Still waiting
  25. Thread: snoop??

    by ETC1
    Replies
    7
    Views
    1,207

    i started using Snoop in 1974. It comes in...

    i started using Snoop in 1974. It comes in galllon jugs and refillable squeeze bottes ith a pullout applicator tube. Its low viscosity alows for easy application and pinponting small leaks. As with...