  1. Replies
    2
    Views
    471

    It is almost never the sensor, It's probably the...

    It is almost never the sensor, It's probably the auger motor.
    Make sure the disc is clear of debris. Remove all of the pellets completely, pull the auger motor and auger.
    Make sure there is no...
  2. Replies
    11
    Views
    1,910

    the picture is tilted ;) quick edit, to make...

    the picture is tilted ;) quick edit, to make picture levelish according to building
  3. Replies
    5
    Views
    584

    Most certs IMO are geared toward making money...

    Most certs IMO are geared toward making money instead of providing a service, like they originally started out to do.
  4. Replies
    13
    Views
    878

    OK, I understand you have liabilities you want to...

    OK, I understand you have liabilities you want to keep to a minimum, but my point is(In my humble opinion) we write things off as "we cant help you" far to often. We may as well have a sticky that...
  5. Replies
    13
    Views
    878

    As long as you didn't connect it to house...

    As long as you didn't connect it to house power(120VAC) you didn't do any damage. However there is something else going on, perhaps a dirty pilot. But we really cant help you since you don't have any...
  6. Replies
    13
    Views
    878

    Hey krober, that sounds correct. we need ore...

    Hey krober, that sounds correct. we need ore information to help you. Whats the mfg and model# of the stove. Is the stove new or used?
  7. The blinking wall control is either a bad...

    The blinking wall control is either a bad connection or a faulty wall control. What you can try is loosen the three wires coming into the back of the unit(red, green, and white) re tighten them...
  8. Replies
    29
    Views
    7,448

    You can't do anything really to the person who...

    You can't do anything really to the person who sold it. But Majestic may do something for you. contact them and see
  9. Thread: help

    by darthvader
    Replies
    5
    Views
    494

    on the head of the valve, you will see 3 screws...

    on the head of the valve, you will see 3 screws and/or spade connectors, pull all wires except thermopile wires off valve, so you should only have the two wires from thermopile connected to valve....
  10. Replies
    8
    Views
    2,027

    I run into this all the time, Building inspectors...

    I run into this all the time, Building inspectors and contractors need to pick up the slack. so many chases are build with nothing but framing. Hearthman hit the nail on the head, it's a sucky job,...
  11. Replies
    5
    Views
    705

    usually once a year is enough, it depends on what...

    usually once a year is enough, it depends on what wood you burn, if you burn softwood you may want it done more often. but usually once a year.
  12. Replies
    5
    Views
    705

    You can have your chimney cleaned that should...

    You can have your chimney cleaned that should help with the smell.
  13. Replies
    2
    Views
    452

    You shouldn't run these stoves on low for...

    You shouldn't run these stoves on low for extended times because its burns less clean and will cause your stove to get dirty fairly fast. what is the cycle time and what is your outdoor temperature....
  14. Check to make sure the vac switch hose is clear....

    Check to make sure the vac switch hose is clear. next make sure stove is clean. check burn pot to make sure all hole are open.
    Remove baffle behind burn pot. clean all the fingers off the heat...
  15. There should be nothing in the hole. something is...

    There should be nothing in the hole. something is jammed in there. It is normal for the stove to auto clean after shutdown. The fire should be out by the time it does auto clean, make sure the stove...
  16. this port should be open and you should be able...

    this port should be open and you should be able to blow a decent amount of air through it. most likely clogged with pellet debris
  17. you most likely need a new remote then

    you most likely need a new remote then
  18. when you press the on/off button press and hold...

    when you press the on/off button press and hold firmly for 2s these remotes are pretty notorious with have low signal strength. also make sure batteries are good.
  19. Thread: gas logs

    by darthvader
    Replies
    23
    Views
    1,865

    Hearthman is correct in that it is a lot of...

    Hearthman is correct in that it is a lot of different things in and cause it. I find when a customer(on propane) runs the tank out or low constantly, I see it more often. The way I understand it(i...
  20. Replies
    3
    Views
    404

    you get what you pay for pretty much

    you get what you pay for pretty much
  21. On a lot of gas fireplaces when you adjust the...

    On a lot of gas fireplaces when you adjust the hi/low flame control, you cant see much difference at all. But if you are worried about it, you need to have a tech out to check pressures at the valve....
  22. Replies
    1
    Views
    409

    clean out the hopper, and make sure there is...

    clean out the hopper, and make sure there is nothing jamming the auger
  23. Replies
    3
    Views
    593

    Most of the time on these units, it a bad...

    Most of the time on these units, it a bad connection where the TC plugs into the control board, sometimes all you need to do is unplug the tc and plug it back in, be very careful when unplugging it...
  24. Replies
    11
    Views
    1,503

    check the outlet, make sure you are getting ~120v...

    check the outlet, make sure you are getting ~120v to ground on the hot side and <5v to ground on the neutral side. Is the call light dim by chance? If the wires from the T-stat get grounded on the...
  25. Replies
    11
    Views
    1,503

    The thermocouple could be bad also, but you...

    The thermocouple could be bad also, but you should get a orange light from the control board.