Search:

Type: Posts; User: re2ell

Page 1 of 19 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    1
    Views
    703

    Have a 275 gallon oil tank in basement. Used from...

    Have a 275 gallon oil tank in basement. Used from 1954 thru 1988......you remove, you may have.
  2. Thread: Jemracks

    by re2ell
    Replies
    2
    Views
    782

    Jemracks

    243371

    243381

    243391

    243401

    selling Jemrack shelving, fits full size Ford...removed from 2007 Chevy 2500 Cargo Express van.
  3. Replies
    2
    Views
    752

    some really good answers @ this thread, hope it...

    some really good answers @ this thread, hope it helps

    http://hvac-talk.com/vbb/showthread.php?t=7148

    :patriot:
  4. If I were in your position, I'd contact the ARI...

    If I were in your position, I'd contact the ARI and equip myself with all the publications available that specifies all the specs you are seeking. This approach would be a sure bet you design it...
  5. Thread: Leak Test Tools

    by re2ell
    Replies
    6
    Views
    470

    H-10, awesome piece of equipment!

    H-10, awesome piece of equipment!
  6. Replies
    6
    Views
    755

    defrost initiation

    Robert, without knowing what specific make of heat pump you have, i'd like to keep my response general of all heat pumps.

    defrost initiation is usually controlled by cycles per time passage and...
  7. Replies
    6
    Views
    1,476

    condensation woes

    sputter, undergound storage tanks in residential applications are subject to the same condensation problems as are service stations dispensing gasoline. periodically, the underground tanks must have...
  8. Replies
    5
    Views
    874

    Calling Lennox

    I second the motion of calling Lennox! Hey Bob says it right, many service personal are not familiar with the Lennox platform, and many, many mistakes have been made because of that.

    Lennox...
  9. something to think about

    [QUOTE]Originally posted by physicsnerd
    [B]My new lennox 3 1/2 ton 13 seer a410 heat pump is going on the roof of my 3 story townhouse. The air handler is in the basement. I estimate the run of the...
  10. Replies
    86
    Views
    6,946

    the humour of it all!

    very late reading this one, but my goodness, the humour hasn't aged one iota!
  11. excellent suggestion!

    excellent suggestion!
  12. considering possibilities

    ntechnic, beenthere says it right. you would have dramatic savings by changing out to 18 SEER or higher. you might want to look into them.
  13. Replies
    9
    Views
    840

    watts of cc heater

    about 7 or less :)
  14. Thread: Superheat

    by re2ell
    Replies
    14
    Views
    1,976

    defining superheat

    freddie, let's define what super heat is. once we thourouly understand the definition, then we can work with it.

    superheat = the number of degrees by which the unsaturated vapor (containing no...
  15. Replies
    6
    Views
    854

    good seeing ya

    Norm, good seeing ya post!
  16. Replies
    6
    Views
    854

    preferences

    tr23, myself, prefer to see 15 degree split or maybe a little less. the only time i've experienced 20 degree td, abnormally high head pressure readings were evident.
  17. Thread: Compressor ?

    by re2ell
    Replies
    1
    Views
    452

    callback

    in the industry, that would qualify as a call back. the one who installed should be able to find the problem and fix.
  18. Replies
    2
    Views
    553

    all your answers

    ultima, you should find all your answers at this website

    http://www.americanmetalproducts.com/vent/amerivent/faq.htm
  19. Replies
    4
    Views
    574

    pesty dryer vents

    hkjrmd, your inspector is telling you right. the more separation you can get, the better. the hot air wouldn't be a problem, however the airborne lint particles will kill a condenser.
  20. Replies
    7
    Views
    877

    in my opinion

    jir, in my honest opinion, i believe what this all means is that we are literally running out of fossil fuels to generate electricity. i live in central indiana and our power here is produced by...
  21. Replies
    10
    Views
    835

    not cheap

    danglerb, continue being who you are. if i lived in southern CA, i'd be worse than you, i've been there and i know what's going on in the industry in your area.
  22. Replies
    7
    Views
    877

    plugging SEER into the equation

    jir, to effectively use the SEER value for calculating cooling usage, one must know the total number of BTU's transfered for the season. without going into all the math, 15 SEER unit will use 44.6%...
  23. Replies
    14
    Views
    1,269

    result of...

    danglerb, the oil is not circulating intentionally, it is a byproduct of compressor design. refrigeration machines (compressors) by design allow a small amount of oil to escape around the...
  24. Replies
    13
    Views
    2,457

    horizontal pitch

    sorethumbs, i see you've been watching and reading this forum for a few days.

    your length should present you no problem, however, be sure the horizontal run pitches in the direction of the...
  25. Replies
    3
    Views
    2,542

    LRA / RLA clarity

    welhan, yes, it means amps

    the LRA is 'locked rotor amps', the amperage draw of the compressor at startup.

    the RLA is 'rated load amps' the amperage draw of the compressor when it is working...