  1. Any one Connected Andover VAV circa 1995 to Jace? Are Drivers needed.. or Bacnet?

    Any one connected Andover to a Jace without the head end? What is required for driver or are they bacnet... I am told we are looking at circa 1995 1996 VAV boxes...I hope to have a model number next...
  2. Replies
    28
    Views
    3,256

    Sorry to rub you the wrong way. I did not write...

    Sorry to rub you the wrong way. I did not write it, but it does exist. I also would tell you more, but until I am given proper permission to do so I must stick by my word. I am sure it will...
  3. Replies
    2
    Views
    590

    Thanks, I am going to try to pull one in to a...

    Thanks, I am going to try to pull one in to a soft jace sometime just to see how they work. These boxes were running stand alone.
  4. Replies
    2
    Views
    590

    Reliable VAV controller and AX

    I had to remove some Reliable VAV controllers, will not go into reasons, but they are Bacnet...Right?
    Can I pull them into a Jace or SoftJace? Do i need special software to set address or do they...
  5. Replies
    28
    Views
    3,256

    You have to live in Ohio. I am not at liberty to...

    You have to live in Ohio. I am not at liberty to give out the information at this time. Just know that it is real. Sorry I cannot give you more.
  6. Replies
    28
    Views
    3,256

    YES!

    YES!
  7. Replies
    9
    Views
    1,782

    Teletrol...AX.....VTs

    ANy one use teletrol and AX, I have heard there is a driver floating around, but I wonder how good it is, and how big of a site? What kind of Performance? I have heard of one driver but it is so...
  8. Replies
    4
    Views
    837

    Just in case anyone has this issue with a Older...

    Just in case anyone has this issue with a Older Williamson Gas Furnace, I took the combustion motor off, and cleaned the flue, and the undersized condensate drains, there was a good amount of water...
  9. Replies
    4
    Views
    837

    Williamson Furnace rolling out

    I am working on an older Williamson 90 plus Nat.Gas furnace and it is rolling out at first light off. I have checked the pressures in the past and it looks good. I few years ago I installed a...
  10. Replies
    2
    Views
    555

    Well I got it to work, all but one point, The...

    Well I got it to work, all but one point, The nviON/OFF will not come through. The factory said the csv file was correct and it should but they could not help so I had to hard wire the remote start...
  11. Replies
    2
    Views
    555

    Airstack with Fieldserver Lonworks????

    Need to know if any one has used the Airstack chiller with the provided fieldserver to Lonworks. I would like to know if it went well and if you had any issues? I am using a Jace BTW. I pulled in...
  12. Replies
    11
    Views
    2,044

    Dell works best with Trane Software. Without all...

    Dell works best with Trane Software. Without all the extra junk on it.
  13. Replies
    17
    Views
    5,772

    HoneyWell XL 5000 Can you Integrate?

    I am being asked if there is a Honeywell XL 5000 integration method, I do not know anything about the Honey well line, so hoping to find some info.
    All I know is that it is a HoneyWell XL5000....
  14. Replies
    14
    Views
    1,701

    Heat pump DIP SW settings, Off, ON, Off, dip 4...

    Heat pump DIP SW settings, Off, ON, Off, dip 4 not used
    Heat Pump with Econ, Off, On, ON, dip 4 not used

    2 Heat 2 Cool, Off, Off, Off
    2 Heat 2 Cool w Econ, Off, Off , ON

    4 Cool On, Off, Off...
  15. Replies
    29
    Views
    2,376

    I did put that in my post, I agree 100% I was...

    I did put that in my post, I agree 100% I was looking at it from the stand point of new commissioining, I think that is what I took from the original post that this is why he wanted the software was...
  16. Replies
    14
    Views
    1,701

    I know in my area the commercial office will sell...

    I know in my area the commercial office will sell the service Rover, this is a scaled down rover that will allow you to configure controllers. I guess it depends on the area you are in, Our local...
  17. Replies
    29
    Views
    2,376

    MAN there sure are a lot of TH,ers,LOL. That is...

    MAN there sure are a lot of TH,ers,LOL. That is Trane Haters by the way.

    Let me put another spin on this.
    If you are putting in the system wether it is Trane or Johnson or What ever, and you...
  18. Replies
    9
    Views
    1,806

    Depending on How old this chiller is, your best...

    Depending on How old this chiller is, your best bet is to do Bacnet to a Jace, I do not think the UCP 2 on a CV can do LON. you get more information out of bacnet any way. You will need a BCU and...
  19. Replies
    1
    Views
    456

    DId you set the DIP switches correct on the TCI...

    DId you set the DIP switches correct on the TCI board? If this is an OLD varitrack it may be that the comm card needs to set up as nonisolated comm 3 comm 4, you do this by rotating the top portion...
  20. Replies
    7
    Views
    2,742

    You can take the model and serial number and...

    You can take the model and serial number and order the options module as a replacement repair part. Just another option.
  21. Replies
    4
    Views
    1,769

    For the money just use the GBAS module and a Lon...

    For the money just use the GBAS module and a Lon IO card of your choice and monitor the water temps with external sensors, program the GBAS to control set point and use the alarm relay to show...
  22. Thread: BCU to Tridium

    by seewll
    Replies
    8
    Views
    1,159

    I think you will see in the next year a change in...

    I think you will see in the next year a change in the Open side of things, I have heard that they will be moving towards offering products that will be either bacnet or Lon at the device level. IMHO...
  23. Replies
    7
    Views
    881

    OH yes it has been done!

    I know some one who has done this, but not sure if they want me to reveal who they are, only comm 4 though. Comm 3 was not worth the time they said.
  24. Replies
    11
    Views
    8,915

    The Kit is Easy! Just turn off power, remove...

    The Kit is Easy! Just turn off power, remove duct, remove screws holding in the old valve, cut wires to motor as close as you can to the old motor and save, just in case you need the extra, put on...
  25. set up for Modbus Catapillar Generator on Jace 2 AX

    Any one set up a Catapillar Generator Modbus serial on a Jace using AX? I am having some issues. I think it is more of the setup in the jace, and maybe a slight wire problem a close second. I...
  26. Replies
    1
    Views
    433

    Batch Editor and Link marking???

    Can you use a Batch editor to link mark. I have a reset for each controller, the web sup has the reset Enum point that links to a NVI reset on each controller, is there a way for me to link mark...
  27. Replies
    2
    Views
    659

    Best Practice for WEB SUP AX

    I am setting up a web sup, and I have only worked with it a little one other time, so I cannot remember much, What DOC do I need to refer to if there is one, I did not see one in my Niagara DOC...
  28. DO I Need to Upgrade AX 3.2 and new building?

    I have a building that is a year old and is 3.2, I am doing the sister building this year and using the same web sup, should I upgrade the two old jaces, and websup to the latest, or just leave them...
  29. Replies
    17
    Views
    2,988

    The magnet location looks like a set of sergeant...

    The magnet location looks like a set of sergeant strips, with white stripes, it has a LED and you need a south pole manget, during binding, it will shut down the chiller, and you will also need to...
  30. Thread: Passed AX

    by seewll
    Replies
    13
    Views
    1,688

    Is there Some where else to get certification? ...

    Is there Some where else to get certification? What about R2, I went to AX at Tridium last year?
  31. Replies
    15
    Views
    1,822

    If I get a chance this week end I will check my...

    If I get a chance this week end I will check my LIT and see what I can find. I always use my PC but Trane made the CCP III so that almost all functions can be done from the Display, not all functions...
  32. Replies
    4
    Views
    635

    I will check my mail.I will be at the summit in...

    I will check my mail.I will be at the summit in May.
  33. Replies
    7
    Views
    926

    GO to the BCU, this is really the only real...

    GO to the BCU, this is really the only real option. There is no other option that I know of.
  34. Replies
    4
    Views
    635

    Hey chris........

    chris the first job we did with these controllers from what we were told, we could not limit them that way?? not sure why. but i did not question it at the time. I am going to be pre configuring the...
  35. Replies
    15
    Views
    1,822

    You need to go into the ccp set up and you should...

    You need to go into the ccp set up and you should be able to set the fan to cycle from the operator display with out the laptop. If you have the software loaded on your lap top you have the PDF...
  36. Replies
    4
    Views
    635

    DISTECH set point limiting?????

    I am working with some Distech HPU units, i will be using the easy stat, that has the temp listed on them instead of the plus and minus. How do you limit them,
    I have used some programming on the...
  37. Replies
    10
    Views
    2,362

    Rover is a one shot deal, per machine so if it is...

    Rover is a one shot deal, per machine so if it is on one machine already, you are out of luck unless you can convince your local salesperson that your original macine died. But it is no different...
  38. Thread: Tracer Summit

    by seewll
    Replies
    34
    Views
    6,890

    You will find that there are many ways to...

    You will find that there are many ways to program, but the UPCM is the "unit" controller that is where all the "meat" of the programming for your AHU operation is at,CPL lives in the BCU and is used...
  39. Thread: Inet, MR88R

    by seewll
    Replies
    5
    Views
    950

    crab master, would you be willing to email me the...

    crab master, would you be willing to email me the docs you posted, I cannot see them or upload??? not sure why, Will the Inet talk bacnet?
  40. Replies
    13
    Views
    1,217

    FreddyB Thanks, I guess other than just looking...

    FreddyB Thanks, I guess other than just looking at ALC it is an expensive graphics package, LOL. Pretty useless as far as real control goes???
  41. Replies
    13
    Views
    1,217

    Any one Doing ALC and a Jace???

    Any one doing ALC controllers and a Jace for the Head, if so What kind of Issues or success have you had, can you offer any things that you wish you would have asked for up front, I may be doing a...
  42. Thread: Inet, MR88R

    by seewll
    Replies
    5
    Views
    950

    Inet, MR88R

    Can any one tell me about this controller, is this a TAC product, and can you use Lon Maker or some other tools to configure or are they fully programmable. Are they LON? Thanks.
  43. Replies
    1
    Views
    444

    Nodebuilder blue book????

    Any one have a copy of node builder blue book? some one said there was some good information in it that could help with tuning Lon Loops. not sure but that is what i was told. Thanks
  44. Replies
    0
    Views
    347

    Lon Tunning for Distech or in General

    Can anyone offer any good Lon "tunning" documents. You will notice my post on crc errors, I think I would like to try some other tunning parameters, but I have not had any former training on TUNNING...
  45. Replies
    9
    Views
    817

    If a system is not properly designed you can have...

    If a system is not properly designed you can have this happen, If a box is oversized this will happen(an oversized box needs a certain amount of DP so this is why putting in a bigger box does not...
  46. Replies
    2
    Views
    486

    Let me give you some history, This is a new Link...

    Let me give you some history, This is a new Link with Lon approved 22 awg wire, with Distech controllers. I know that the link is good, it is terminated properly and I have repeaters in the middle....
  47. Replies
    4
    Views
    696

    Thanks that is a good document.

    Thanks that is a good document.
  48. Replies
    2
    Views
    486

    CRC Errors on Jace with DISTECH HPU units

    I am getting some issues with having to rebind links like space temp and ocupancy, any one have this issue. I have some crc errors over a 5 minute window, I am going to be going back with a LPA...
  49. Replies
    4
    Views
    696

    Thanks I have the white document, I will look...

    Thanks I have the white document, I will look through it again, I did not remember seeing any particular set up information, I was hoping someone has used this scope, It is always nice to get some...
  50. Replies
    4
    Views
    696

    Fluke Scope Meter Settings for LON Check

    any one use the Fluke 196c scope to check the lon link, What settings did you use.