  1. That's helpful. Thank you. I think I'll adopt...

    That's helpful. Thank you. I think I'll adopt that approach.
  2. Replies
    54
    Views
    9,295

    They did however start me at $40/hr. So I feel...

    They did however start me at $40/hr. So I feel like I shouldn't be complaining. Is that enough to not complain about those other things?
  3. Replies
    54
    Views
    9,295

    Non-tech tasks

    What about other tasks like parts and drive time between stores?
  4. In-house tech: everything should be fixed the first visit?

    I'd say about 90% of the calls I get for our McDonald's stores are repaired the first visit. However, there are times where I find a common problem that looks like the cause of all the symptoms and...
  5. Replies
    54
    Views
    9,295

    Typical overtime policies?

    I'm an in house HVACR technician for a McDonald's franchise. I'm the only one in the company that does HVACR. I'm an employee not an independent contractor.

    I only get overtime after 8 hours if...
  6. Yeah it's a 3 stage package unit, everything is...

    Yeah it's a 3 stage package unit, everything is shared. I'm just wondering why I'm only getting 1400 cfm from the return air duct. Is that all that a 13" inside diameter duct can get? I mentioned...
  7. So at the evaporator my airflow meter is reading...

    So at the evaporator my airflow meter is reading 5400 cfm. When I manually close the economizer and take the reading at the return air inlet inside the restaurant I get 1400 cfm. There are two...
  8. Condenser coil is clean and fins are fairly...

    Condenser coil is clean and fins are fairly straight, good airflow. Also, airflow across evaporator is within specs.
  9. 3 stages, same pressures, different subcooling

    Lennox LGA/LHA180 package unit

    Ambient: 85F

    Condensing temp: 122F
    SC 1: 34F
    SC 2: 18
    SC 3: 25

    Evap temp: 42F TXV metering
  10. Replies
    12
    Views
    2,201

    Finding cause for blown fuses

    I have a walk-in freezer blowing fuses almost every day usually around 8:30pm, defrost is set at 6:00pm for 40 minutes. First it was blowing the 30A fuse on the safety disconnect for the first leg...
  11. Replies
    6
    Views
    1,113

    anyone got any ideas? I have to go back to work...

    anyone got any ideas? I have to go back to work on this unit soon.
  12. Replies
    6
    Views
    1,113

    Icing accumulator when flushing

    I'm working on a Franke reach-in freezer for one of our stores. I diagnosed it as a plugged cap tube because the suction was way low and it was overcharged. Dryer was fine, and it wasn't equalizing...
  13. That is crazy... so crazy I think it's just the...

    That is crazy... so crazy I think it's just the thing I was looking for.
  14. Best way to unclog/change out orifice?

    Carrier
    Model: 48TMD012-A-501--

    I have 4 partially clogged orifices on the 2nd circuit of this package unit. I've already tried flushing nitrogen at high pressure in reverse flow and they're...
  15. Replies
    14
    Views
    1,728

    Pump down without receiver?

    I'm working on the walk-in cooler in a MAC 6 fo one of our mcdonald's store. Evaporator is a Bohn model MCA0901D. It's got a starved evaporator, uneven frost pattern. I need to know what type of...
  16. Replies
    10
    Views
    1,352

    I'll try to clarify

    I don't think it's a low charge because there's no temperature difference across the txv. The suction pressure says that it should be about 20-25 at the outlet of the txv and I'm getting 75 at the...
  17. Replies
    10
    Views
    1,352

    York Model: D2CG180N24025ECA So this is my...

    York Model: D2CG180N24025ECA

    So this is my first time working on parallel compressors. Two 5 ton compressors connected to the same refrigerant lines. Head pressure 160 psi / suction 45 psi....
  18. Replies
    10
    Views
    1,352

    Parallel Compressor Troubleshooting

    York Model: D2CG180N24025ECA

    So this is my first time working on parallel compressors. Two 5 ton compressors connected to the same refrigerant lines. Head pressure 160 psi / suction 45 psi. ...
  19. Condenser Fan

    It is a small condensing unit used only for the walk-in cooler, no mac 6 or 7 at this store. Also, no name plate so the info for the evaporator is all I have. The bimetal switch is definitely not...
  20. Low Ambient Fan Speed Control on Walk-in Cooler

    I have a couple general questions about low ambient high and low speed fan controls for walk-in coolers in the los angeles/san fernando valley area. How crucial is it to have the two speeds in this...
  21. Replies
    9
    Views
    1,165

    Thanks!

    Thanks all! It worked out well. I backed off the nitrogen more and just made sure there was enough ventilation. Did all 8 welds without turning too purple. :) Next time I'll know how to do enough...
  22. Replies
    9
    Views
    1,165

    Icemaker brazing trouble

    Alright, I applied for pro membership because I need it. Anyone know how long it takes to get approved?

    Until then, I need your guys' advice on a problem I'm having brazing an ice-o-matic ice...
  23. Replies
    12
    Views
    2,434

    Evap coil

    Is there a way to check cfm without an air flow meter? The evaporator was clean all the way through and the fins were straight, rotation was correct and the blower wheel/blades looked like they were...
  24. Replies
    12
    Views
    2,434

    Two stage package unit icing up

    Carrier
    Model: 48TMD012-A-501--
    Voltage: 240 V, 3 PH
    Pressures circuit 1: 34/210 R22
    Suction line temp: 40
    Pressures circuit 2: 45/210 R22
    Suction line temp: 50
    Ambient: 75

    On circuit...
  25. Replies
    11
    Views
    1,483

    Repairing leak on U-tube junction

    https://lh3.googleusercontent.com/Yz74Wtc-QuZoeYq4OOf0X_JWc4sjGvq6QrLLC5ADeu3rLrVOAmA5d91E_2gjli8yHiwacAO_v7030-4kKi7lnbiGqg=s512

    In the picture above there's a leak on the bottom u-tube on the...
  26. yeah, I was wondering upon reflecting on the...

    yeah, I was wondering upon reflecting on the symptoms if that's what it might be. I'm not sure how long it was running without the fan, the manager just told me he turned the unit off after hearing...
  27. update

    update: the manager now says that it was hissing before and that's why they turned it off and called for service. so apparently it wasn't anything I did. Also, I don't think this is effecting it...
  28. Hissing sound after condenser fan motor changeout

    I have a franke 7rf01 reach in freezer (wall mounted). Service call was that the condenser fan motor wasn't running. I confirmed it was bad and changed it. It's running fine now but there is a...
  29. Replies
    8
    Views
    1,641

    Thanks! that gives me a lot to go on. And yes...

    Thanks! that gives me a lot to go on. And yes dry ice was in the box to preserve the product while the system was off -- sorry for the confusion on that. I'm going to get a better vacuum pump so it...
  30. Replies
    8
    Views
    1,641

    temp inside box is 20 and dropping. there's...

    temp inside box is 20 and dropping. there's still dry ice from evacuating the system for a few hours.
  31. Replies
    8
    Views
    1,641

    Walk-in Freezer

    I have a walk-in freezer with a new compressor running 408a. Compressor model number is LAHA-0320-TAC and it's a copeland. There were a couple leaks, one at the fitting for the high pressure...
  32. Replies
    28
    Views
    6,429

    work van and truck stock parts

    The company I work for is getting me a work van and I wanted to ask you guys what Ford van you recommend?
    I only work on mcdonalds units, so commercial air and heat as well as refrigeration.
    ...
  33. thermostat

    Only one is operated by thermostat. And besides, there's proper voltage at the motors. the manager said it stopped working when it started raining two days ago. Its still raining now, but I have a...
  34. condenser fans not running on walk-in freezer

    I apologize if this is not the right section of the site to post this and that its not in the pro forums but regardless, if you guys could help me with this that would be great. I have a walkin...
  35. Replies
    17
    Views
    1,608

    Thanks Gleng

    Well many of my technical questions that I have googled have brought me to this site, so I apologize for not realizing that there were distinct forums for pros and DIY's. Thanks gleng for actually...
  36. Replies
    17
    Views
    1,608

    manufacturer info

    Does the manufacturer usually tell you what superheat after the heat exchanger is supposed to be?
  37. Replies
    17
    Views
    1,608

    came here for help

    Isn't this supposed to be a safe place to ask questions? Lets assume your right and I don't understand the refrigeration cycle. Why don't you be more specific as to what I don't understand? Also,...
  38. Replies
    17
    Views
    1,608

    checking superheat on an insulated line

    So this is my first post on here. I'm a student who also has the privilege to work on mcdonalds hvac/r systems for a living. I have a general refrigeration question regarding reach in boxes with...