Search:

Type: Posts; User: Mr toon

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    11
    Views
    2,100

    Awesome

    Awesome
  2. Replies
    28
    Views
    1,941

    would havehad pee down both legs! and sprayed...

    would havehad pee down both legs! and sprayed that sucker with coil cleaner
  3. Replies
    14
    Views
    2,838

    yes me too the connex stat is awesome enjoying...

    yes me too the connex stat is awesome enjoying the four wire hookup throughout, the evolution extremes are pretty rad
  4. Replies
    14
    Views
    2,838

    nice install the infinity is same as bryant...

    nice install the infinity is same as bryant evolution correct?
  5. take temp readings on both sides of said dryers...

    take temp readings on both sides of said dryers that will tell you if its restricted
  6. Replies
    12
    Views
    418

    ive got fieldpiece pocket psycrometer little...

    ive got fieldpiece pocket psycrometer little silver pen looking deal not sur model #
  7. Replies
    12
    Views
    703

    check strainer before txv, seems the txv is...

    check strainer before txv, seems the txv is responding to temp changes on the bulb
  8. Replies
    12
    Views
    418

    thanks, my readings dont add up then think my...

    thanks, my readings dont add up then think my psycrometer might be off
  9. Replies
    0
    Views
    208

    friday the 13th yep

    rough one today spent two hours this morning chasing a restriction factory strainer in condenser, overlooked by me several times, then clean an service call with 2014s dirtiest evap winner on gaspack...
  10. Replies
    12
    Views
    418

    oh crap thats a bit much lol, what does WB really...

    oh crap thats a bit much lol, what does WB really tell me is 62 WB humid at 76*DB im really not sure
  11. Replies
    5
    Views
    332

    11 requirednindoor txv subcool as per unit data...

    11 requirednindoor txv subcool as per unit data plate i had 18 *sc nd 18* SC 21* temp drop but r22suction sat temp 36 and suction line temp54 im really thinking poor airflow
  12. Replies
    5
    Views
    332

    just wandering if txv systems should gennerally...

    just wandering if txv systems should gennerally follow target sh formulas or not because ive always heard to pay attention mostly to sc on txv systems
  13. Replies
    5
    Views
    332

    was a poor cooling preformance service call, unit...

    was a poor cooling preformance service call, unit seemed undersized 3ton unit on older 2200 sq ft double wide with addition, sh seemed a little high but so did sc both around 18 to 20 so didnt want...
  14. Replies
    12
    Views
    418

    understanding Wetbulb temperature

    is there a formula to calculate humidity using WB and DB temps for example 76DB and 62WB this house felt humid
  15. Replies
    5
    Views
    332

    target superheat with txv system

    Have a dumb question should a TXV system follow the target superheat as per formula, i took WB and Db temps and using my sman3s came up with a 6.7 target superheat but system running at 18 sh, does...
  16. fieldpiece hs36 best allaround i think

    fieldpiece hs36 best allaround i think
  17. Replies
    20
    Views
    1,416

    1 gallon shop vac pain in butt if pan is full

    1 gallon shop vac pain in butt if pan is full
  18. have inificon techmate finds leaks pretty well...

    have inificon techmate finds leaks pretty well and is not too pricy just be sure to have spare senors {diodes) whatever you call thm
  19. Replies
    11
    Views
    902

    Check rollout

    Check rollout
  20. check all the way to panel

    check all the way to panel
  21. check your grounds ive had weak grounding cause...

    check your grounds ive had weak grounding cause wierd issues with flame sense
  22. Thread: Magic Trap

    by Mr toon
    Replies
    9
    Views
    1,584

    lol looks like they gotta little crazy with the...

    lol looks like they gotta little crazy with the primer/glue on vents as well
  23. Thread: Commercial job

    by Mr toon
    Replies
    21
    Views
    4,012

    across from wky publishing, next to lynx?

    across from wky publishing, next to lynx?
  24. Thread: Commercial job

    by Mr toon
    Replies
    21
    Views
    4,012

    new building van gaurd sighn out front, nursing...

    new building van gaurd sighn out front, nursing home?
  25. Thread: Commercial job

    by Mr toon
    Replies
    21
    Views
    4,012

    nice install what building is this?

    nice install what building is this?
  26. Replies
    8
    Views
    412

    Gas heat is probably what ill take for now, ive...

    Gas heat is probably what ill take for now, ive heard it was the easiest to pass, are their any books or study guides you would recommend?
  27. Replies
    8
    Views
    412

    what do you recommend studying? are their alot of...

    what do you recommend studying? are their alot of airflow and ductszing questions, not really a strong suit for me
  28. Replies
    8
    Views
    412

    one year hvac trade school,one year as helper,...

    one year hvac trade school,one year as helper, now two years in field as journeyman service tech
  29. Replies
    8
    Views
    412

    prepping for NATE test

    :Faint: i have decided to attempt to get NATE certification, looked at some practice tests and its a bit scary any one have some suggestions on preparing for the exam?
  30. Replies
    59
    Views
    5,022

    Too much in pockets lol, wife hates when blue...

    Too much in pockets lol, wife hates when blue wire nuts zip screws and Schrader caps end up rattling around in dryer lol
  31. Replies
    59
    Views
    5,022

    Good ole western ky

    Good ole western ky
  32. Replies
    17
    Views
    1,484

    Yep was there that was our whole crew all 5 of us

    Yep was there that was our whole crew all 5 of us
  33. Replies
    17
    Views
    1,484

    How u likin new co? I see y'all's trucks...

    How u likin new co? I see y'all's trucks everywhere
  34. Replies
    17
    Views
    1,484

    Geometric company lol, they cut so many corners...

    Geometric company lol, they cut so many corners they should be called circle instead lol,,,
  35. Home warranty companies are terrible if you find...

    Home warranty companies are terrible if you find a unit that needs to b condemned they will call in a second opinion from another co and they will get the changeout, it's not good for business to...
  36. Replies
    17
    Views
    1,484

    Dealing with home warranty company's

    :gah: don't you love dealing with home warranty cos, my gosh had 3 home warranty calls today each time I was on hold waiting confirmation for repair far 30 mins to an hour then they try to haggle...
  37. Replies
    37
    Views
    3,781

    Sman 3 best bang for buck in my opinion

    Sman 3 best bang for buck in my opinion
  38. Replies
    4
    Views
    534

    Got a uei bout a month ago not bad on price seems...

    Got a uei bout a month ago not bad on price seems tough
  39. Replies
    14
    Views
    2,354

    Call code enforcement

    Call code enforcement
  40. Replies
    47
    Views
    3,915

    Sman 3, Klein 11 in one , fieldpiece hs36 ,...

    Sman 3, Klein 11 in one , fieldpiece hs36 , hitachi 18 v drill and flashlight kit,,,, who needs anything else
  41. Replies
    6
    Views
    1,465

    How in the world did they get that off the roof...

    How in the world did they get that off the roof thieves got dedication
  42. Thread: Backup meter

    by Mr toon
    Replies
    7
    Views
    544

    I like the hs36 it's the handiest meter but its...

    I like the hs36 it's the handiest meter but its kinda like putting all your eggs in one basket
  43. Thread: Backup meter

    by Mr toon
    Replies
    7
    Views
    544

    Mfd not mods sorry

    Mfd not mods sorry
  44. Thread: Backup meter

    by Mr toon
    Replies
    7
    Views
    544

    Backup meter

    I'm I the market for a backup meter while my hs36 Is being repaired any suggestions price is an issue, looking for a good meter 200 and under, also what is your opinion all in one meter like the hs36...
  45. Replies
    13
    Views
    939

    Had it right at a year so disappointed I love...

    Had it right at a year so disappointed I love this meter
  46. Replies
    13
    Views
    939

    Not that I know of is there an internal fuse ?

    Not that I know of is there an internal fuse ?
  47. Replies
    13
    Views
    939

    Yes meter beeps and problem persists even when I...

    Yes meter beeps and problem persists even when I unplug test leads but mfd capacitance is the only thing not working
  48. Replies
    13
    Views
    939

    Already changed battery what is range toggle?

    Already changed battery what is range toggle?
  49. Replies
    13
    Views
    939

    Field piece hs36 prob

    :gah: my fp hs36 as of the last call today quit reading capacitance , when on Mfd it just beeps and numbers go up for example I was reading a 10 mfd blower cap and it just beeped and numbers were...
  50. Replies
    9
    Views
    677

    SBKOLD got no pics of the coil but you can google...

    SBKOLD got no pics of the coil but you can google old singer ac unit and there is a youtube video with an identicle unit
Results 1 to 50 of 151
Page 1 of 4 1 2 3 4