Search:

Type: Posts; User: silkysean

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Replies
    18
    Views
    1,244

    If you replaced a R-22 Unit with another one i...

    If you replaced a R-22 Unit with another one i take it you flushed system because original was a burnout.If so i always replace coils.Its just to hard flushing out debris,etc out of distributor...
  2. Replies
    2
    Views
    386

    Be safe and confident call your tech and let him...

    Be safe and confident call your tech and let him deal with it.And if it hasn't been serviced yet get a 2 for 1 instead of service call just request clean and tune and he will find it while...
  3. Replies
    15
    Views
    1,400

    Weil McLein or Peerless or Lockinvar

    Weil McLein or Peerless or Lockinvar
  4. Replies
    2
    Views
    524

    Have it serviced by an hvac professional...

    Have it serviced by an hvac professional contractor.Too many variables when it comes too heat.Burners dirty,over firing,possible clog,crack,chimney clogged or not drafting or just plan bad...
  5. What scares me is your are messing with a system...

    What scares me is your are messing with a system your not qualified to service.Thats like me trying to fix computers i may know a little something and in my case worse case i fry computer,etc.In your...
  6. Replies
    37
    Views
    3,565

    Great work and install thought i was one of few...

    Great work and install thought i was one of few who still caulks disconnect box.Can tell its professional work
  7. Replies
    8
    Views
    735

    Sounds like a hack job and if poorly serviced and...

    Sounds like a hack job and if poorly serviced and maintained alot of problems and money.Also the fact that they choked it down is restricting the airflow.I also bet your evap and condenser coils are...
  8. Replies
    11
    Views
    679

    It all depends on total number of supplies and...

    It all depends on total number of supplies and runs but if you think its not blowing enough air call a air balance specialist or hvac company that can look at it for you.There's too many variables...
  9. Replies
    23
    Views
    1,640

    I dont Like it either but then again i charge...

    I dont Like it either but then again i charge time and a half and double on holidays.If we dont go Business makes no money.So i Love weekends and holidays for the money.In my area it weeds out the...
  10. Replies
    14
    Views
    5,415

    If you looking to learn and see all kinds of...

    If you looking to learn and see all kinds of hacked up work by subs and skipping lunches along with being rushed go ahead.Again great place to start to learn but once experienced take it elsewhere I...
  11. Replies
    17
    Views
    2,744

    oh yeah

    oh yeah
  12. Replies
    12
    Views
    4,363

    Have him check hx usually the Lockinvars hx gets...

    Have him check hx usually the Lockinvars hx gets plugged after awile and due to lack of maintenance or cleaning especially since burners cracked this indicates clogging and poss over firing as well.
  13. Replies
    2
    Views
    581

    We're looking for someone in your area to do...

    We're looking for someone in your area to do service in deep soth area's if u want email me resume i'll see if u fit with our team i run techs in chi-town area you'd start off as a trainee cause you...
  14. Replies
    5
    Views
    764

    Units come with an airflow switch mounted in...

    Units come with an airflow switch mounted in blower compartment try bypassing or jumping out cause if you get nothing to happen in test modes chances are either airflow switch or bad board my moneys...
  15. Replies
    22
    Views
    1,905

    Let me say this thank u to Dan sw...

    Let me say this thank u to Dan sw fl,keepyoiucool2003,klrogers,maxsters for explaining this cause all your points are right and no one tends to account for light heat load and fresh air requirements...
  16. Replies
    9
    Views
    6,168

    yes and no as i stated a lot of factors determine...

    yes and no as i stated a lot of factors determine this it all depends on length and width this truly dictactes offset for formula
  17. Replies
    9
    Views
    6,168

    Like what it means offset*width/length u...

    Like what it means offset*width/length u basically are just mitering the duct for an offset all it is is a formula if u have duct 20 width 5 ft long and need an offset of 2 20*2=40/5=4 inches taken...
  18. Thread: uv rectifier

    by silkysean
    Replies
    3
    Views
    665

    Slimwood i would agree with that its usually the...

    Slimwood i would agree with that its usually the amp. or purge card but in this instant i as well as others are coming across completely bad relays all together.Put new purge cards and amp cards and...
  19. Thread: uv rectifier

    by silkysean
    Replies
    3
    Views
    665

    I have the same problem at work still have 3 more...

    I have the same problem at work still have 3 more relay modules to replace for a total on my end of 6 bad and another co-worker had 2 and more to follow i think it's internal surge protecter goes bad...
  20. Replies
    5
    Views
    623

    I too stay near this area far soth suburb and...

    I too stay near this area far soth suburb and have a 1880 sq. ft house 3 ton a/c 100,000 btu input furnace lots of windows and doors both grossly oversized per my calculations and having done better...
  21. Replies
    4
    Views
    569

    the coil should have a model and serial # close...

    the coil should have a model and serial # close if coil isn't that old and as far as telling cap. by counting i don't know of anyone in their right mind that would do that and 2 yes u can install a...
  22. Replies
    14
    Views
    1,433

    A two-stage furnace is a wonderful thing it's not...

    A two-stage furnace is a wonderful thing it's not loud and if u want better comfort get a twostage variable speed furnace if u can,make sure the furnace is sized correctly or waste of money will...
  23. Replies
    4
    Views
    874

    With Aprilaire i always use their outdoor sensor...

    With Aprilaire i always use their outdoor sensor with humidistat and use seperate transformer to power up humidifier especially with Lennox Furnaces because it puts strain on trans,also if t'stat is...
  24. Replies
    10
    Views
    1,383

    Though not an ARI Match it is completely...

    Though not an ARI Match it is completely combatible with all systems and it still will operate just as efficently.I don't know why people think just because the coil isn't made by same mfr. u don't...
  25. Vs motors are always the way to go if u have the...

    Vs motors are always the way to go if u have the money and a choice but if getting all replaced consider a two stage heating and two stage cooling with outdoor sensor for max dehumiddification.Sam to...
Results 1 to 25 of 52
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event