  1. Hi there.... I should have explained a little...

    Hi there....
    I should have explained a little more carefully.

    The vessel is exactly as you described. The leaking/migrating refrigerant is not venting to atmosphere.... rather, it is leaking...
  2. York YCAV Rust within vessel + service manual?

    Hi there.

    We have a York YCAV 0739pa (dual screw, vsd, air cooled) chiller leaking refrigerant between circuit 1 and 2.... as well as leaking liquid refrigerant directly into the suction line.
    ...
  3. Thread: Turbo core?

    by izombie
    Replies
    40
    Views
    4,853

    Im working on turbocors all the time, half of our...

    Im working on turbocors all the time, half of our installations are air cooled condensers. We had some problems when ambient starting creeping above 35'C, but modifying the lag compressors startup...
  4. Thread: Turbocor ARI?

    by izombie
    Replies
    0
    Views
    337

    Turbocor ARI?

    Hi there.
    Does anyone know if the Turbocor has been independently certified on its COP ratings as advertised?
    Thanks.
  5. Replies
    2
    Views
    713

    Hi Balibe thanks for the reply, Today we found...

    Hi Balibe thanks for the reply,
    Today we found that the PSIO module (sorry- my mistake, not hsio) programming had become corrupted for reasons unknown. The batteries in the controller, and the...
  6. Replies
    2
    Views
    713

    30GB CCN comms problem?

    Hi guys,
    I was working on 3x carrier 30gb systems today, one of them (chiller1) lost its display on the hsio while in CCN-OFF Mode. I cycled power to the hsio, but now all that happens is, it...
  7. Replies
    6
    Views
    624

    Hi there thanks for the input. Unfortunately I...

    Hi there thanks for the input.
    Unfortunately I could not get the serial/model numbers today.

    Im only getting this code on chiller #2 (hsio) . Sometimes, chiller #1 will shutdown, and not respond...
  8. Replies
    6
    Views
    624

    Thanks for the offer, I don't have that...

    Thanks for the offer, I don't have that information on hand with me at the moment, i will write it all down for you and reply here tomorrow.
    Cheers
  9. Replies
    6
    Views
    624

    Thanks Manson, sounds promising the only problem...

    Thanks Manson, sounds promising the only problem is, I come from Australia and it does not appear to accept my details.
  10. Replies
    6
    Views
    624

    Flowtronic Lowlevel comms failure.

    Hi there, i have a flowtronic 2, dual chiller system that pops up the error code 66 - low level comms fault. I noticed that the earthing shield terminal had been removed from the low level comms...
  11. Replies
    15
    Views
    2,996

    No worries, ill see how i go if i upgrade. With...

    No worries, ill see how i go if i upgrade. With win98, i simply remove the carrier entries in msconfig/startup. to open up com1 again to other programs, I dont know if i have ever tried it by only...
  12. Replies
    15
    Views
    2,996

    Ahh ok, well i will try my luck at getting a hold...

    Ahh ok, well i will try my luck at getting a hold of version 2 for the on site computers, as i dont really want to have to upgrade them all to xp. Version 3 might be good for my laptop though :) Does...
  13. Replies
    26
    Views
    1,885

    I worked in IT for a few years doing various...

    I worked in IT for a few years doing various programming projects, system design, network security, stuff like that. I.T in one form or another, has been in my blood ever since my parents decided to...
  14. Replies
    15
    Views
    2,996

    Thanks guys, I was able to get the database to...

    Thanks guys,
    I was able to get the database to download and setup. Quite straight forward actually, except that i thought something had failed, as there were no values in the status column. A...
  15. Replies
    15
    Views
    2,996

    Thanks mikelcs, Ill have a go at doing it like...

    Thanks mikelcs, Ill have a go at doing it like that.... Do you know if the version 1.00 comfortview software will be sufficient? I suppose it should be, it currently has databases on it for other...
  16. Replies
    15
    Views
    2,996

    Carrier 6400 access?

    Hi there.
    I am about to start servicing an old carrier plant, after the previous contractors were caught, not doing their job properly. Apparently, the site uses a carrier 6400 ddc setup, i am...
  17. Replies
    11
    Views
    2,047

    Yes, it was the superheat sensor alright. Nice...

    Yes, it was the superheat sensor alright. Nice easy fix too. Thanks very much for your help.

    Referteacher, you meantioned that you had worked on the 30 GX's. Have you ever known of an oil PD of...
  18. Replies
    11
    Views
    2,047

    Thanks for your help. Ill check the thermistors...

    Thanks for your help. Ill check the thermistors first thing on monday morning.
  19. Replies
    11
    Views
    2,047

    Yes, there are 3x recips per circuit. The...

    Yes, there are 3x recips per circuit.

    The system starts up, watching the system controller, and the pc hooked up via CCN, i can see the analog data for circuit a indicating that the EEV is open at...
  20. Replies
    11
    Views
    2,047

    Ahh yes, my mistake sorry. its a 30GB. The name...

    Ahh yes, my mistake sorry. its a 30GB. The name plate and instrumentation indicates R22. :)
  21. Replies
    11
    Views
    2,047

    Hi there. Im working on a twin circuit carrier...

    Hi there.
    Im working on a twin circuit carrier system on R22. The problem is with the EXV on circuit A, not being able to open more than 19.1%. I have observed this via CCN and the chiller...
  22. Replies
    2
    Views
    610

    Hi there. I have been asked to takeover CCN...

    Hi there.
    I have been asked to takeover CCN related work at my company after the leading mechanic left. We have ComfortView 1, but no related documentation, does anyone know how to go about...