Search:

Type: Posts; User: pcp

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    3
    Views
    175

    Had a couple noise complaints with them that's...

    Had a couple noise complaints with them that's all.
  2. Replies
    4
    Views
    320

    I normally remove condensate trap. Never had an...

    I normally remove condensate trap. Never had an issue with which screw is installed 1st.
  3. You likely have an old master slave stat set up....

    You likely have an old master slave stat set up. Main floor needs to be in desired mode to work. If this is the case there us nothing wrong.
  4. Replies
    10
    Views
    420

    That ignitor I believe should be under 10 ohms

    That ignitor I believe should be under 10 ohms
  5. Replies
    57
    Views
    2,613

    What did the other techs at your shop say?

    What did the other techs at your shop say?
  6. The h10 is used exclusively at our company now...

    The h10 is used exclusively at our company now and dyes are no longer used. Very worth it.
  7. Thread: Cutting Plaster

    by pcp
    Replies
    33
    Views
    1,065

    When cutting round holes through a ceiling, cut a...

    When cutting round holes through a ceiling, cut a basketball in half put a hole in the ball for the drill bit then put it between the hole saw and the drill. It will catch everything and keep dust...
  8. Thread: pressure issues

    by pcp
    Replies
    6
    Views
    384

    Go to school and have someone beat it into your...

    Go to school and have someone beat it into your head. It's the easiest way.
  9. Replies
    47
    Views
    1,834

    Tmi. Imo

    Tmi. Imo
  10. Replies
    23
    Views
    1,149

    Is the heat pump found. Is it a communicating...

    Is the heat pump found. Is it a communicating heat pump.
  11. Your buddy must hate you I know I would.

    Your buddy must hate you I know I would.
  12. Replies
    4
    Views
    516

    If it opens on limit in one stage it will run in...

    If it opens on limit in one stage it will run in another stage and may not lose temp. Don't assume nothing is wrong though. These limits are touchy and the furnace can run very close to limit temp
  13. Replies
    16
    Views
    811

    Look at the plug from the front not the back and...

    Look at the plug from the front not the back and see if it makes more sense.
  14. Replies
    7
    Views
    376

    I think I did one of these a couple years ago and...

    I think I did one of these a couple years ago and I think you might be looking at the plug from the wrong direction.
  15. Thread: On Call Incentive

    by pcp
    Replies
    58
    Views
    4,654

    We get $150 for the week, 1.5 time port to port...

    We get $150 for the week, 1.5 time port to port and $25 per call. All companies should charge enough to make it worth while for the technician to give up there time.
  16. Replies
    15
    Views
    1,099

    It helps expose gas valves and inducers to...

    It helps expose gas valves and inducers to moisture and they sell more parts.
  17. Replies
    14
    Views
    2,879

    Easiest to pull the burner box unless the...

    Easiest to pull the burner box unless the installer glued in the combustion pipe. Company I work for has a lot out there where they glued in street 90s
  18. Thread: problem customers

    by pcp
    Replies
    48
    Views
    4,064

    How much does it cost to buy an egg at the...

    How much does it cost to buy an egg at the grocery store and why is it so much more at a restaurant? People just don't think.
  19. Is there a link to Carrier's memo? I can't find...

    Is there a link to Carrier's memo? I can't find it.
  20. Think you would need a nim control to do this.

    Think you would need a nim control to do this.
  21. Do you work for honeywell? I'm not a fan of nest.

    Do you work for honeywell? I'm not a fan of nest.
  22. Try putting cork pads under blower housing if its...

    Try putting cork pads under blower housing if its a vibration issue.
  23. Replies
    7
    Views
    946

    Bryant 383 has same HX.

    Bryant 383 has same HX.
  24. Replies
    7
    Views
    946

    Yes you can see them with the blower out. The...

    Yes you can see them with the blower out. The dimples by the limit seem to be the last to crack, and they crack if the baffles are there or not, smaller units don't have the baffles.
  25. Replies
    1
    Views
    360

    That's the model number for your evaporator coil.

    That's the model number for your evaporator coil.
Results 1 to 25 of 86
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event