Search:

Type: Posts; User: ksspartan

Page 1 of 4 1 2 3 4

Search: Search took 0.00 seconds.

  1. Replies
    11
    Views
    2,792

    Thanks so much for your efforts in getting with...

    Thanks so much for your efforts in getting with the Lennox Tech. I checked my resistance and have concluded my sensor was bad. I am ordering a new sensor today.
  2. Replies
    11
    Views
    2,792

    I sure would appreciate what ever you can find...

    I sure would appreciate what ever you can find out.
  3. Replies
    11
    Views
    2,792

    Does anyone know how to test an outdoor...

    Does anyone know how to test an outdoor temperature sensor to determine if its bad? I am trying to avoid buying a new one and finding out that this did not correct my problem. My thermostat is...
  4. Replies
    11
    Views
    2,792

    I am using shielded wire so I don't think it the...

    I am using shielded wire so I don't think it the wire. So before I purchase a new outdoor air sensor does anyone know how to test the sensor. Is there an ohm reading that it should test out at.
  5. Lennox Series 7000 Thermostat Outdoor Temperature Sensor

    I have a Lennox Series 7000 ComfortSense Thermostat with an Outdoor Sensor (X2658)connected. The thermostat is reading -1F when its 65 degrees out. I checked all the wiring and it appears to be...
  6. Replies
    11
    Views
    2,792

    Lennox Series 7000 Outdoor Sensor

    I have a Lennox Series 7000 ComfortSense Thermostat with an Outdoor Sensor (X2658)connected. The thermostat is reading -1F when its 65 degrees out. I checked the wiring and it appears to be wired...
  7. Replies
    55
    Views
    5,964

    Dan Thanks for the clarrification. I even...

    Dan

    Thanks for the clarrification. I even feel better about my investment now.
  8. Replies
    55
    Views
    5,964

    Lyork, Just got my electric bill for February....

    Lyork,

    Just got my electric bill for February. My total gas and electric consumption for the month of February are as follows

    Electric ending 3/6
    bill--$121.65
    usage--2896 kwh
    days--34
    ...
  9. Replies
    55
    Views
    5,964

    LYork, Got my gas bill yesterday. 7.2 MCF vs...

    LYork,

    Got my gas bill yesterday. 7.2 MCF vs 16.2 MCF last year. Thats a 56% savings over last year. Not quite as good as your 69% savings that you got. What do you keep your set point at? ...
  10. Replies
    55
    Views
    5,964

    Dan, Thanks for the suggestion on the light...

    Dan, Thanks for the suggestion on the light bulbs. I'll give them a try and see if they work in my fixtures.

    Brjones, I agree on running the heat pump as long as I can given our low Kwh cost. I...
  11. Replies
    55
    Views
    5,964

    Robertshaw 98201 appears to be the same stat that...

    Robertshaw 98201 appears to be the same stat that Lennox calls their Signature Stat. When I originally posted my first thread I was concerned about the 4100 Kwh electrical usage in December. My low...
  12. Replies
    55
    Views
    5,964

    Thank LYork As you mentioned earlier, you and...

    Thank LYork

    As you mentioned earlier, you and I have talked a few months back. I believe you mentioned you were in Shawnee. I'm in Olathe. My home is similar size but its a ranch with a dormer....
  13. Replies
    55
    Views
    5,964

    So from your load calc data I should set my high...

    So from your load calc data I should set my high balance point at 31 and my low balance point at 22. My stat is set to only alow the heat pump to operate at outdoor temps above the high balance...
  14. Replies
    55
    Views
    5,964

    Thanks Dan. I will compare total usage with...

    Thanks Dan. I will compare total usage with LYork come the end of the month.

    Couple of questions:

    What makes you think I have a defrost problem? I'm assuming thats your best quess given my...
  15. Replies
    55
    Views
    5,964

    I got the G61MPV-110 furnace. Low fire 75,000...

    I got the G61MPV-110 furnace. Low fire 75,000 Btuh Input/72,000 Btuh output. High fire 110,000 Btuh Input/99,000 Btuh output.

    Main Floor, Loft, and Basement all served by the same system. All...
  16. Replies
    55
    Views
    5,964

    Lennox Model G61MPV Gas Furnace with HPXA 19 Heat...

    Lennox Model G61MPV Gas Furnace with HPXA 19 Heat Pump

    Ranch Style Home : 1712 SF First Story, 376 SF Loft, 1024 SF Basement (Walkout - South Exposure)

    Total Window Area: 363 SF Window Area
    ...
  17. Replies
    55
    Views
    5,964

    Designer Dan, If I understand your math...

    Designer Dan,

    If I understand your math correctly at 4100 Kwh in a month I am providing approx 40,000,000 BTUh. You mentioned this didn't seem like it was overly excessive. Do you still think I...
  18. Replies
    55
    Views
    5,964

    Lyork, I had my lower balance point set at 10. I...

    Lyork, I had my lower balance point set at 10. I was under the impression that I should try to get as much as possible out of my heat pump but maybe I was pushing its limits and running my...
  19. Replies
    55
    Views
    5,964

    I recently installed a 16 SEER dual source Lennox...

    I recently installed a 16 SEER dual source Lennox heat pump (gas backup). I live in Kansas City where the local electric utility gives a rate reduction incentive to go to an electric heat pump (4.3...
  20. Replies
    12
    Views
    1,407

    Just thought I would let you guys know my...

    Just thought I would let you guys know my results. Your suggestions were exactly what was causing the noise. The installers fastened the refrigerant lines to the joists in my basement with metal...
  21. Replies
    12
    Views
    1,407

    I'll try both ideas. RoBoTeq, I have to ask,...

    I'll try both ideas.

    RoBoTeq, I have to ask, what is a ignot? Are these something I can purchase at the local hardware?

    t527ed, Are these metal sleeves you speak of supposed to be removed...
  22. Replies
    12
    Views
    1,407

    The refrigerant lines are approximately 30 feet...

    The refrigerant lines are approximately 30 feet long. The systems is a Lennox G61MPV Variable Speed Gas Furnace with a Lennox HPXA19 Heat Pump. Both are marketed as being extremely quiet. I...
  23. Replies
    12
    Views
    1,407

    I recently had a heat pump installed. The charge...

    I recently had a heat pump installed. The charge was checked and was a bit high so they removed a portion of the freon. The lines were noisy and have quieted down somewhat but unfortunately the...
  24. Replies
    42
    Views
    2,861

    I figured out why my refrigerant lines were...

    I figured out why my refrigerant lines were making so much noise. Temperatures in Kansas City finally reached the high twenties and my heat pump went out on high head pressure. The contractor put...
  25. Replies
    42
    Views
    2,861

    Great to hear Mopar Guy. I do allot of design...

    Great to hear Mopar Guy. I do allot of design work with Lennox Technical Support so I asked them to send me the wiring diagram for my system using the Signature Stat and it showed this jumper in a...