    PXC200-E.D is a DESIGO part. You will need to be...

    PXC200-E.D is a DESIGO part.
    You will need to be in a country where DESIGO is supported.
    You are correct, this is just the controller. You will also need Power Module(s) and TX-I/O modules. These...
  2. Replies
    8
    Views
    985

    I have a PXC Compact running BACnet 3.1. I had...

    I have a PXC Compact running BACnet 3.1.
    I had to use the encoded naming convention to command some Binary Outputs in a different manufacturer's panel.
    For example,
    To turn on a binary output...
  3. Replies
    8
    Views
    985

    What kind of controllers are being used?

    What kind of controllers are being used?
  4. Replies
    12
    Views
    1,857

    The only problems that you could really take care...

    The only problems that you could really take care of on an Open Processor or an MEC would be configuration or firmware issues.
    You could troubleshoot down to the board level, depending on the...
  5. Replies
    21
    Views
    4,064

    NO. The older MEC Expansion Modules did not have...

    NO. The older MEC Expansion Modules did not have an isolated trunk, and did not have a baud rate switch. They were designed to be used specifically on the MEC's expansion port in a 'same room'...
  6. Replies
    21
    Views
    4,064

    What version of Field Panel firmware do you have,...

    What version of Field Panel firmware do you have, and what version of Insight?
  7. Replies
    29
    Views
    4,128

    UCIS was the 'CIS' used to talk to the UC.

    UCIS was the 'CIS' used to talk to the UC.
  8. Replies
    29
    Views
    4,128

    run-time error R6009 - not enough space for...

    run-time error R6009
    - not enough space for environment


    The error seems to be caused by the different DOS command interpreter used by Windows XP (cmd.exe vs. command.exe).

    I was able to use...
  9. Thread: PPCL Question

    by lost0ne
    Replies
    38
    Views
    4,740

    Seriously?

    Seriously?
  10. Replies
    68
    Views
    5,412

    Open: the ability to mix and match components of...

    Open: the ability to mix and match components of a particular layer between different manufacturers.

    If a system supports the ability to utilize different manufactures' equipment at the different...
  11. Thread: Mstp Wiring

    by lost0ne
    Replies
    4
    Views
    1,325

    Some of the proprietary RS-485 based protocols...

    Some of the proprietary RS-485 based protocols have been based on a two wire concept. The RS-485 is a differential signal which is presented on two wires. Internally the communication power supply is...
  12. Replies
    14
    Views
    2,882

    There is the DEFINE statement which helps...

    There is the DEFINE statement which helps facilitate the use of virtual points for testing. Use general point names in your PPCL and define some virtual points for testing.
    Place the DEFINES...
  13. Replies
    4
    Views
    1,270

    The APOGEE PXC Compact Controllers are available...

    The APOGEE PXC Compact Controllers are available in a Native Bacnet Version.
    These will work with APOGEE Insight. You might have to upgrade to 3.9 or 3.91, and include the BACnet software.
    The HMI...
  14. Replies
    4
    Views
    1,270

    PXC22-E.D are DESIGO units. You will need...

    PXC22-E.D are DESIGO units.
    You will need something to configure them with; DTS, X-Works, etc.
    I know that APOGEE can see them as third party devices, but I haven't really done anything beyond...
  15. Replies
    37
    Views
    12,921

    The PXC Compact Controller is a global product,...

    The PXC Compact Controller is a global product, used with both APOGEE (mostly US) and DESIGO (mostly Europe).

    It is available as a 16 point or 24 point unit (US) and as a 12 point or 22 point unit...
  16. Replies
    8
    Views
    2,384

    If you are talking about using the Ethernet ALN...

    If you are talking about using the Ethernet ALN then you are talking about using a proprietary protocol.
    The PXC Modular has one Ethernet port. Depending upon which Modular you get it either talks...
  17. Replies
    4
    Views
    1,066

    There are seperate owner's manuals. I'll send you...

    There are seperate owner's manuals. I'll send you one for the Compact.
    I don't think that there are specific user's manuals; they are both covered in the APOGEE Field Panel User's manual.
    Will this...
  18. Replies
    4
    Views
    1,066

    Compact or Modular?

    Compact or Modular?
  19. Replies
    7
    Views
    1,299

    The MBC will be supported for many years. Even...

    The MBC will be supported for many years. Even after a product is no longer offered for new sales it is typically supported for at least 7 years.

    The PXC Modular Controller (A.K.A. Modular, or...
  20. Replies
    11
    Views
    18,556

    Here is what I found for the display module.

    Here is what I found for the display module.
  21. Replies
    11
    Views
    18,556

    I'll check.

    I'll check.
  22. Replies
    11
    Views
    18,556

    Landis & Gyr PolyGyr controllers

    Here are some of the original data sheets.
  23. Replies
    11
    Views
    18,556

    I remember those (and the brownish plastic room...

    I remember those (and the brownish plastic room sensors).
    I'll check and see if I have any documentation at work tomorrow.
  24. Replies
    12
    Views
    2,039

    I am not very familar with Datamate but the...

    I am not very familar with Datamate but the user's manual saya that it should be able to use the .P2 file.
    What version do you have?
  25. Replies
    3
    Views
    1,096

    There are Integration drivers that can be loaded...

    There are Integration drivers that can be loaded in some APOGEE controllers to support MSTP LANs.

    There are also native BACnet versions of Siemens Controllers.

    The Insight Software has both a...