  1. Seems like you're low on charge or have a...

    Seems like you're low on charge or have a restriction. SH of 30 is a little high. With those readings, your target SH should be about 19 degrees. SH too high will make the compressor run hot. Also...
  2. Replies
    16
    Views
    1,992

    Check ball valves for in-line screens. I had a...

    Check ball valves for in-line screens. I had a supply ball valve with a clogged screen in it. Not the strainer style. Just a small screen similar to one you see on a faucet.
  3. X3

    X3
  4. Replies
    104
    Views
    23,632

    [in cooling] The Lennox Approach method is the...

    [in cooling] The Lennox Approach method is the difference in "condenser-air entering temperature" and the liquid line temperature, as opposed to sub-cooling method of liquid line temp & condenser...
  5. Replies
    104
    Views
    23,632

    & let us not forget the 3rd charging method... ...

    & let us not forget the 3rd charging method... And that is the Approach method used on Lennox TXV systems. ;)
  6. Replies
    5
    Views
    678

    Great info! thanks bob_scheel.

    Great info! thanks bob_scheel.
  7. Replies
    5
    Views
    678

    I appreciate your response. However I already...

    I appreciate your response. However I already knew that. That's what I said. What I need to know is how to figure what amps you should be getting based on the FLA of the indoor blower motor... ?
  8. Replies
    5
    Views
    678

    Proper blower amperage

    How do you figure what the proper range is for amperage on an indoor blower motor?

    For example: Let's say the FLA for the indoor blower motor is 4.8. Generally, how many amps should you be...