  1. Replies
    17
    Views
    911

    Yea so when I got done putting another txv that's...

    Yea so when I got done putting another txv that's different from the one I got thefirst time. I had like 2 deg super heat with t first txv that iI replaced. So they sent me another one that was...
  2. Replies
    17
    Views
    911

    U know I asked about the sanitize light being on....

    U know I asked about the sanitize light being on. And tech support said that don't matter
  3. Replies
    17
    Views
    911

    I know when I check the valves on a semi I close...

    I know when I check the valves on a semi I close the service valve see how long it takes to get in a vac.then I unplug power to see if it holds. That's on 1 to 1 1/2 HP. If it rises right away I was...
  4. Replies
    17
    Views
    911

    Guys I appreciate all your help. This is why I'm...

    Guys I appreciate all your help. This is why I'm reaching out. I'm going by tech support cause the evap and comp is under warranty. But their answeres don't make since and I agree with you. Good...
  5. Replies
    17
    Views
    911

    I first replaced evap. It was under warranty....

    I first replaced evap. It was under warranty. After that tech support said bad txv. Replaced that now I got height suction. 85psi start 55 when done it takes over 30 mins to make a batch. Comp is...
  6. Replies
    17
    Views
    911

    OK I double checked the water inlet. It fills to...

    OK I double checked the water inlet. It fills to proper level then shuts off I can hear it. The water never gets higher. And I can see the drain and no water is coming out.so I replaced the txv....
  7. Replies
    17
    Views
    795

    OK I got txv to 10 deg superheat. Now its pulling...

    OK I got txv to 10 deg superheat. Now its pulling down a lot faster. Thanks for the reply. Ohh by the way my supervisor told me never check superheat and he said word of advice. Never adjust txv they...
  8. Replies
    17
    Views
    911

    scotsman Help!

    I have a Scotsman M#CU1526SA-1A. S#090413200140 first came up to it and it was pretty limed up. And I had ice on the bottom but not the top of evap. Suction was at 60 psi and 300 head with a 70...
  9. Replies
    17
    Views
    795

    I'm Omw their now. I'll try it and post back

    I'm Omw their now. I'll try it and post back
  10. Replies
    17
    Views
    795

    The txv is adjustable... that's the only thing I...

    The txv is adjustable... that's the only thing I know to do.
  11. Replies
    17
    Views
    795

    Let me give more info. I do a lot of coolers and...

    Let me give more info. I do a lot of coolers and freezers that come in a shop from stores. We refer Bush the units and send them back out. This two door master Bilt freezer is a ongoing problem I...
  12. Replies
    17
    Views
    795

    OK I did recover the charge replaced drier let...

    OK I did recover the charge replaced drier let the system pump down over night. And weighed in the correct charge. It has a txv. Evap outlet temp is -7 now. I haven't checked line temp at the comp yet
  13. Replies
    17
    Views
    795

    404A designed for ice cream cut in 0 out -15. Did...

    404A designed for ice cream cut in 0 out -15. Did not look at specs
  14. Replies
    17
    Views
    795

    master bilt freezer

    I have a 2 door Master Bilt Freezer self contained Model# BLG-48HDA Serial# PV498760. Problem is that it gets to 0 degrees then takes forever toget down to cut out -15. Like 30-45 mins. This is what...
  15. Replies
    10
    Views
    937

    I figured outthe pro. Thanks for the help

    I figured outthe pro. Thanks for the help
  16. Replies
    10
    Views
    937

    How do I get pro status? I been on this for years...

    How do I get pro status? I been on this for years just never asked much. Mostly just read for knowledge and help. Yea we have two other service guys. And they like the whole beer can cold
  17. Replies
    10
    Views
    937

    Thanks for the reply. I wish I had someone with...

    Thanks for the reply. I wish I had someone with the knowledge to help me in the field. I work with a small company and other guys have bad behaviors. When I get stuck I wish I could instant message...
  18. Replies
    10
    Views
    937

    superheat? subcooling?

    Hey everyone.... I need the truth I've herd so much crap about how to check super heat on a 404 freezer? First I work for a refrigeration company that NEVER checks superheat or sub cooling. They go...
  19. Replies
    26
    Views
    1,335

    No I'm a service guy. The company that worked on...

    No I'm a service guy. The company that worked on this unit before me couldn't get it fixed. The replaced the bin sensor with the Johnson control. Then they replaced the board. Then that didn't work...
  20. Replies
    26
    Views
    1,335

    Yea I went over the wiring with tech support for...

    Yea I went over the wiring with tech support for the Johnson stat. Jumpers and everything. But I'll look at your link and double check. Last night when I left the ice/clean/off switch unplugged....
  21. Replies
    26
    Views
    1,335

    OK I replaced the bin sensor back to a new bin...

    OK I replaced the bin sensor back to a new bin sensor that came with themodel. Pulled out the JC tstat.I checked all the wiring. Then I ran a power cord from the main breaker box to the ice machine....
  22. Replies
    26
    Views
    1,335

    Yes it is a 120V system. I'll check main power...

    Yes it is a 120V system. I'll check main power supply for correct connections. Thanks
  23. Replies
    26
    Views
    1,335

    The original sensor wasn't installed when I got...

    The original sensor wasn't installed when I got on it. So the Johnson control has a temp probe that screws in on the back wall inside the bin. So it only detects ice when it gets high enough. I'm...
  24. Replies
    26
    Views
    1,335

    OK so I'll say pretty much everything I know....

    OK so I'll say pretty much everything I know. M#QF0406A S#110978811. It was installed Jan 2012. Before I got on it a company came out said the bin lightwould not go out so they replaced tthe bin...
  25. Replies
    26
    Views
    1,335

    Manitowoc flaker... completely stumped!!!

    I have a under counter flaker. I'll post M#+S# later today. Its had everything done to it. When its turned the full bin light come on the board. But the bin is empty. Tried pulling the bin sensor...