  1. Replies
    11
    Views
    852

    It seems to be overcharged with 95 psi at suction...

    It seems to be overcharged with 95 psi at suction line. What was the wet bulb in the house? What about air flow... Coils are clean?
  2. Replies
    14
    Views
    1,390

    The only time to replace it.... Is when it goes...

    The only time to replace it.... Is when it goes bad... Call your service company please...
  3. I don't think he doesn't... Any contractor will...

    I don't think he doesn't... Any contractor will do it, what makes difference is the price and the quality. Now you can go trough the season without it and earn some money and get the true steam......
  4. Replies
    11
    Views
    1,094

    Obviously capacitors will be tested in mfd's........

    Obviously capacitors will be tested in mfd's..... Only clarifying.
  5. Replies
    11
    Views
    1,094

    All will be determinated, by ohms reading,...

    All will be determinated, by ohms reading, depending on manufacture, that's why there is not a determinated time for capacitor and/or hsi... I guess.
  6. Replies
    33
    Views
    3,499

    1 how do you know is running backwards?, I don't...

    1 how do you know is running backwards?, I don't know any 3 phase residential system... Where did you go? Call your contrator.
  7. Replies
    44
    Views
    2,785

    Attic is an attic, not an storage, specially if...

    Attic is an attic, not an storage, specially if you have your unit up there. And yes would be ideal if you upgrade your attic insulation.... Don't forget your system need enough space to get it...
  8. Replies
    23
    Views
    1,842

    Well, do you know what kiss me means? Keep it...

    Well, do you know what kiss me means? Keep it simple as you and me or whatever, posibly relocating that specific branch will help, or eliminate it, there are no quite grills, more fency grill reduce...
  9. Replies
    33
    Views
    3,499

    If you read the warranty part, it is clear,...

    If you read the warranty part, it is clear, warranty is voided for abuse, ligthning, or any damage from mother nature. Now all depends how the companies follow the rules, or what deal you can get...
  10. Replies
    13
    Views
    1,328

    if they don't care warranties... They don't care...

    if they don't care warranties... They don't care nothing
  11. Replies
    75
    Views
    9,807

    Good for him... I hope everytjing was took care...

    Good for him... I hope everytjing was took care and now you are enjoying your comfort. But I am wondering when they will come back...?
  12. Replies
    27
    Views
    2,877

    Blower door test, will give you some numbers,...

    Blower door test, will give you some numbers, then you need a duct sealing process
  13. Replies
    13
    Views
    1,328

    It is clear in the installation book, if you...

    It is clear in the installation book, if you purchase on line, warranty will be voided... Read instructions first, before you get yourself in troubles.
  14. Replies
    78
    Views
    4,752

    You need to think in the future, most of the...

    You need to think in the future, most of the equipments will become variable speed motors. So need to have .5 "wc of static pressure, just another reason why.
  15. Replies
    78
    Views
    4,752

    Undersize return and supply ductwork, noisy,...

    Undersize return and supply ductwork, noisy, slugging your compressr with liquid, overheating your heat exchangers, higher cost to have a comfort level.
  16. Replies
    13
    Views
    1,309

    Is the filter dirty?... It is clogged, imagine...

    Is the filter dirty?... It is clogged, imagine how ia the coil, wheel, even if it is above coil, could colect some. Have someone to come out.
  17. Replies
    7
    Views
    848

    A picture will help, but service valves, can...

    A picture will help, but service valves, can leak... Yes
  18. Replies
    9
    Views
    971

    Call a service company, and get someone who know...

    Call a service company, and get someone who know what it is doing. Or pay down the road, what could be an Small issue... It will become a pain in your wallet.
  19. Replies
    15
    Views
    1,358

    Water caused leak????? B.S.

    Water caused leak????? B.S.
  20. Replies
    15
    Views
    1,358

    You have a leak guaranteed, one of posters said...

    You have a leak guaranteed, one of posters said "Your system is a sealled system", at least at the begining wasn't charged properly, never should be added refrigerant, beside if its a king valve or...
  21. Replies
    9
    Views
    2,063

    You can use it in your condensate pump and/or EZ...

    You can use it in your condensate pump and/or EZ trap or the other trap, never inside of coil box.
  22. Replies
    75
    Views
    9,807

    Is your house and your family, was only a...

    Is your house and your family, was only a recomendation, good luck I hope you will get it fix
  23. Replies
    75
    Views
    9,807

    Since the beginning of your problem you should...

    Since the beginning of your problem you should call, you better gonna turn system off 36 or 48 hours remaining until your company come out, how long the problem started? + at least 40 hours more....
  24. Replies
    75
    Views
    9,807

    Yes call your service company, and have them come...

    Yes call your service company, and have them come out, you are in the installaion warranty period. Possibly wirea are not making good contact, call them, you will avoid further issues down the road...
  25. You need to start since the begining, with good...

    You need to start since the begining, with good and accurate tools, meter you need fluke(set clamp on and digital meter,f116), at least 2 set of manifold gauges yellow jacket titan or brute highly...
  26. Replies
    19
    Views
    1,470

    I have no idea where u live, but if the o.d temp...

    I have no idea where u live, but if the o.d temp is higher than the set up it will continuosly happen until temp goes down. Now probably the 24ANA1 is set in off or on only, thats why it runs for 10...
  27. Replies
    19
    Views
    1,470

    Well if you go through your set up in the system...

    Well if you go through your set up in the system high cool latch is one of them, that is set at ON, 80,85,90,95,100 degrees farenheit that means if your system is set at 90 degrees your compressor...
  28. Replies
    19
    Views
    1,470

    You have the possibility to adjust fan on low. M...

    You have the possibility to adjust fan on low. M
    Medium, high, but when ac runs it does on automatic, if the set up for high cool latch is on, high cool will run when o.d. temp is above determinated...
  29. Replies
    2
    Views
    628

    Nothing is perfect, specially with this career,...

    Nothing is perfect, specially with this career, you can not be perfect, you have days and days, the units are a piece of equipment, just be honest,thorough, with your job and your customers.
  30. Well, the major issue with this systems is static...

    Well, the major issue with this systems is static pressure, for a 90-95 degree day, your supeheat is high, depending the tools your tech use and how accurate they are. Well system looks like low in...
  31. Replies
    4
    Views
    527

    Check your power, low volt fuse, any safety drain...

    Check your power, low volt fuse, any safety drain is open, low voltage wire loss connection. These are a most common reasons for a blank display with infinity controls or some comunication systems.
  32. Replies
    17
    Views
    1,211

    Looks like is undercharge, low pressure switch...

    Looks like is undercharge, low pressure switch shorting 24 volt circuit, so many times will end up on thermal overload, or hard lock out by low presssure. If I am not wrong
  33. Replies
    9
    Views
    958

    probably you have infiltration through the...

    probably you have infiltration through the ceiling and leakage on your duct system, then your duct system must not exceed 0.5"wc of static pressure. Well that problem as you all know is called...