  1. Replies
    17
    Views
    602

    My concerns would be ref flood back and duct...

    My concerns would be ref flood back and duct sweat.

    1st, Like the captcomp said, make sure you have a suction accumulator.

    2nd install a freeze stat on the coil that will energize low speed...
  2. Replies
    36
    Views
    959

    It's funny that everyone compares the hoses at 6'...

    It's funny that everyone compares the hoses at 6' lengths.
    Let's keep in mind, friction rate has to do with length as well as diameter.

    I do believe that a larger hose will evacuate more...
  3. Replies
    6
    Views
    241

    It's a great tool for calibrating other testing...

    It's a great tool for calibrating other testing tools like vane & hot-wire
    anemometers, but like Rundawg said, you gotta have a nice straight section of duct, or an area of low turbulence.
  4. Replies
    9
    Views
    431

    In an open ended enclosure (pipe or duct) at a...

    In an open ended enclosure (pipe or duct) at a continuous volume of flow, static pressure will reduce as velocity increases.
    Likewise, velocity will reduce as static increases.
  5. Replies
    9
    Views
    431

    Pressure which is perpendicular to direction of...

    Pressure which is perpendicular to direction of flow.
  6. Replies
    48
    Views
    1,344

    Does anyone have a link to a government site...

    Does anyone have a link to a government site proclaiming this is law?
  7. Replies
    28
    Views
    979

    You need to evaluate how much the job is worth to...

    You need to evaluate how much the job is worth to you.

    If you are prepared to gather facts, letters from mfg's for proper line sizing, and then having an ongoing dispute with the HOA, then do the...
  8. My question on the two wire kickstart is, does it...

    My question on the two wire kickstart is, does it reduce running efficiency due to the fact that two inductors are in series? The pot relay and the start winding. Though, I guess the pot relay coil...
  9. Yes, you need to alter your combustion air value...

    Yes, you need to alter your combustion air value if you use a direct vent furnace.
    I routinely remove 100Mbtu furnaces and replace with 80's, sometimes 60's.
  10. Replies
    11
    Views
    343

    It will give you the total capacity of the...

    It will give you the total capacity of the system.
    If you can accurately read the condenser fan cfm, and temp diff. Then simply use sensible heat formula - fan & compressor heat.
    Good luck with...
  11. Replies
    13
    Views
    533

    I would test for the root cause, and yes I would...

    I would test for the root cause, and yes I would advise in many cases the blower will fail in the near future.
    You could also perform a motor winding insulation test. This may or may not prove to...
  12. Replies
    19
    Views
    738

    From what I've read dealing with multiple motor...

    From what I've read dealing with multiple motor equipment having internal over load protection , the Min Amp rating is given by calculating 125% the largest motor's RLA + 100 % all other motors' RLA.
  13. Replies
    19
    Views
    738

    You may want to read Timebuilders post and take...

    You may want to read Timebuilders post and take his suggestion to read article 440...
  14. Typically you would size the supply vents by the...

    Typically you would size the supply vents by the amount of throw or face velocity you are trying to achieve. Normal range is usually 400-600 fpm.

    With 20 4"x10" supplies delivering 1200 cfm, your...
  15. I wonder if this a solid state stator design? I...

    I wonder if this a solid state stator design?
    I bought a gasless yard trimmer a year ago with this technology.
    http://coreoutdoorpower.com/technology/

    I made a post about it, but only one...
  16. Replies
    19
    Views
    1,301

    With a cap double the rated size, you may have...

    With a cap double the rated size, you may have over heated the compressor, but the internal over load would take it out. Continually overheating a compressor can cause not only windings to weaken,...
  17. Replies
    18
    Views
    948

    I'm not understanding the math. Where did the...

    I'm not understanding the math. Where did the extra multiple of 1000 come from?
    You're saying a 3/4hp motor will supply 33,557,000 watts of work in an hour?
  18. Replies
    18
    Views
    948

    33557 kWh is 33,557,000 watts per hour?

    33557 kWh is 33,557,000 watts per hour?
  19. Replies
    10
    Views
    584

    The formula is to calculate reactance. XC = 1 /...

    The formula is to calculate reactance.
    XC = 1 / (2 π x f x C)
    Where:
    XC = capacitive reactance
    f = frequency
    C = capacitance
    Π = 3.141592654

    So, we take the known 1/ (2 π x 60) = 0.00265258
  20. Replies
    47
    Views
    2,564

    I'm on my 3rd pair of Dr. Martens in 3 years....

    I'm on my 3rd pair of Dr. Martens in 3 years. They are the most comfortable full leather shoes I've worn. I can't do boots...
    The first pair is not worn out I just scuffed them up and got them too...
  21. I never understood,"trade-in" or "buy-back"...

    I never understood,"trade-in" or "buy-back" programs from mfg's. It's kinda misleading, as if we can do something with the old junk unit, besides scrapping the metal.
  22. Replies
    8
    Views
    856

    Masters licenses in each field you plan to...

    Masters licenses in each field you plan to perform work in, and a contractors license A,B, or C.
  23. Replies
    40
    Views
    1,973

    The input legs L1 & L2 polarity in respect to one...

    The input legs L1 & L2 polarity in respect to one another, have absolutely no bearing on direction.
    The relationship of the run winding to start winding to capacitor are what can alter rotation.
    ...
  24. If it's a standard psc motor, the power...

    If it's a standard psc motor, the power consumption will reduce with greater static, it just won't move as much air.
    Which is odd because this year you reduced static increasing the power...
  25. Replies
    9
    Views
    354

    There's nothing crude about a hand-held...

    There's nothing crude about a hand-held anemometer. They make several useful types of air flow measurement devices. A good technician should have something to get close enough to make the system...