  1. Replies
    9
    Views
    1,287

    great news re:isn

    thats great news to hear about the york device I'am sure the engunears that developed theese devices never intended too make them so difficult that know one could service ( recucitate) them! :cool:
  2. Thread: surging

    by whatusi
    Replies
    22
    Views
    2,847

    condenser water setpoint

    the factory says you can go as low as 14 degrees above the leaving chilled water setpoint with the condenser water setpoint . think about that!what they are telling you is keep the differential to a...
  3. Thread: surging

    by whatusi
    Replies
    22
    Views
    2,847

    condenser watersetpoint

    the factory says you can go as low as 14 degrees above the leaving chilled water setpoint with the condenser water setpoint .!what they are telling you is keep the differential to a minimum ive seen...
  4. Replies
    9
    Views
    1,287

    is there a front end and is FM running if so...

    is there a front end and is FM running if so there is an icon looks like a safe you can usually restore the program from there. if not than the set up guide is essetial
  5. Replies
    9
    Views
    1,287

    ISN set up

    As you have discovered you can set up and communicate to theese devices using vt100 , they are set up in the feature ., section., page format depending on the type of chiller you have set up in...
  6. Replies
    14
    Views
    1,806

    thats just not right !

    an xl was the old style of integration that also required what york called a chiller linc device the new style is just a microgateway that is usually a very chatty device , this sickens me too hear...
  7. Replies
    14
    Views
    1,806

    master slave/ token pass,or ip.

    response time may be an issue in the g-way what is the lan speed of the mstp side of the router. what kind of status lite flashes does the g-way have when offline
  8. Replies
    6
    Views
    2,173

    2550 board is the key here

    port 1 is the port and you must do some configuring of the board from the key pad
  9. Replies
    16
    Views
    1,192

    air cooled or water cooled , is KW a concern and...

    air cooled or water cooled , is KW a concern and who is going to maintain it my prefference is the york ease of trouble shooting , and the optiview is helpfull to bldg engs. all at fair price!
  10. Replies
    10
    Views
    1,883

    linc central

    the york linc central is a gateway device that does just that lincs you to another cpu like a 1095 board or a 1065 board what is the linc attached too :cool:on the 485 side