  1. Thread: Magic Chef

    by atoztech
    Replies
    4
    Views
    684

    Pretty straight forward and easy. 5/16 screws...

    Pretty straight forward and easy. 5/16 screws holds chassis. Remove electric slide out remove 4-6 1/4" screws and remove blower housing.
  2. No offense but poor attitude. Your an electrical...

    No offense but poor attitude. Your an electrical engineer? Is there a schematic at the unit? If so you should have no problem reading it.
  3. Thread: Co Detectors

    by atoztech
    Replies
    4
    Views
    464

    Testo comb. analyzer & Bacharach co detector.

    Testo comb. analyzer & Bacharach co detector.
  4. Replies
    15
    Views
    5,597

    ::DD:

    ::DD:
  5. As long as its your common on the secondary going...

    As long as its your common on the secondary going to your chassis ground its fine, but make sure its grounded to common. Is this an imediate short on a call for heat or intermittant?
  6. Replies
    14
    Views
    1,850

    :LOL: We have installed 1-3 a day for the last...

    :LOL: We have installed 1-3 a day for the last year and have not had any issues that you speak of.
  7. Replies
    29
    Views
    1,988

    Hmmm, i have replaced at least a dozen of these...

    Hmmm, i have replaced at least a dozen of these with shorted windings and have never recieved any relays with the new motors. How are these wired? I assume into the 120 leg that closes the relay?
  8. Thread: payne furnace

    by atoztech
    Replies
    7
    Views
    712

    I dont think he ever said his company didnt put...

    I dont think he ever said his company didnt put them in. Agree with the oils from manufacturing.
  9. Replies
    15
    Views
    5,597

    The new "black" s 86's are garbage imo. The old...

    The new "black" s 86's are garbage imo. The old grey boxes were much better. They dont sense the flame very well, i have had 3 or 4 with brand new pilot assemblies give a low signal code and lockout....
  10. Thread: Carrier RTU

    by atoztech
    Replies
    13
    Views
    1,545

    I used to love the show kids in the hall.:grin2:

    I used to love the show kids in the hall.:grin2:
  11. Replies
    25
    Views
    1,760

    My wife bought a HP back in 2008.The speakers...

    My wife bought a HP back in 2008.The speakers went out once and thats it.Been pretty solid.Think she paid around 6 though.
  12. Replies
    7
    Views
    1,411

    Why would you want to do this?

    Why would you want to do this?
  13. Replies
    15
    Views
    1,610

    :LOL:

    :LOL:
  14. Replies
    6
    Views
    843

    Coil on contactor .39 a gas valve main .30.Your...

    Coil on contactor .39 a gas valve main .30.Your good either way. Its always a habit for me too take it off the transformer directly though.
  15. Replies
    32
    Views
    5,327

    Comfortmaker had a few issues on a few models of...

    Comfortmaker had a few issues on a few models of placement of the ignitors.I actually just saw another on an 80% that was delaying but not to the extreme you stated.This was an uplflow so possibly...
  16. Replies
    32
    Views
    5,327

    Ok, got ya.Thats not a smart valve to clear up...

    Ok, got ya.Thats not a smart valve to clear up confusion.Thats just a 24 v valve. Was it a delayed ignition? I would def check for a gas leak in the vestibule and check the location on the ignitor.
  17. Replies
    32
    Views
    5,327

    Oh yeah whats the model #??

    Oh yeah whats the model #??
  18. Replies
    32
    Views
    5,327

    If it has a smart valve it should have a pilot....

    If it has a smart valve it should have a pilot. Am i missing something? Every smart valve has a rod/ignitor assembly. Is it the diagnostic smartvalve or non? Is the valve gray or tan?
  19. Replies
    10
    Views
    4,284

    If your pressure's are good and you wired it...

    If your pressure's are good and you wired it directly to the transformer and its still acting the same its a weak solenoid.As long as your pilot and oriface is clean too.
  20. Replies
    4
    Views
    1,375

    Pics tooooo small.:whistle:

    Pics tooooo small.:whistle:
  21. Replies
    2
    Views
    614

    Temp star is same as comfortmaker.Its a soft l/o....

    Temp star is same as comfortmaker.Its a soft l/o. 4 trials for ignition failed.For some reason the burners didnt light.Many reasons why this would occur.
  22. Replies
    63
    Views
    5,474

    Commercial and resi pm's going like mad and no...

    Commercial and resi pm's going like mad and no heat calls started back a month ago.
  23. Replies
    42
    Views
    4,451

    Where did you get this info?? The factory rep for...

    Where did you get this info?? The factory rep for comfortmaker and rep for honeywell both couldnt answer this question for me. Fresh out of the box they're 2-3 ohms.
  24. Replies
    13
    Views
    2,207

    I bought one and returned it.I didnt like it and...

    I bought one and returned it.I didnt like it and couldnt get used to it.I work with another tech that swears by it and loves it.Too each his own i guess.:.02:
  25. Ditto on changing both motor and module.Did you...

    Ditto on changing both motor and module.Did you test windings?
  26. Replies
    16
    Views
    1,476

    Prove it failed? They had a class action lawsuit...

    Prove it failed? They had a class action lawsuit against them for this lol.:whistle:
  27. Replies
    16
    Views
    1,476

    Past few years we did quite a few warranty...

    Past few years we did quite a few warranty secondarys for bryant/carrier.Have not had any this year as of yet. Most of my cust opt for the credit towards a new one.
  28. Thread: Thermocouple

    by atoztech
    Replies
    31
    Views
    2,075

    Maybe im incorrect.This is what was told to me...

    Maybe im incorrect.This is what was told to me many years ago. Maybe someone can chime in and clear the air.
  29. Thread: Thermocouple

    by atoztech
    Replies
    31
    Views
    2,075

    Well an open reading on a fresh tcouple is 30 mv....

    Well an open reading on a fresh tcouple is 30 mv. A closed reading is typically half. So if a closed reading is 15 (on a fresh tcouple) and you have a drop out of 15 mv i would think you would be...
  30. Thread: Thermocouple

    by atoztech
    Replies
    31
    Views
    2,075

    That all depends how strong the magnet is.You...

    That all depends how strong the magnet is.You have to test it. But typically a drop out of under 4 mvdc is acceptable.
  31. Replies
    6
    Views
    1,056

    I will almost always quote the interface and a 24...

    I will almost always quote the interface and a 24 volt stat on those early voyagers.The dc trane stat is such a pita.
  32. Replies
    10
    Views
    1,607

    Check in the electrical compt.

    Check in the electrical compt.
  33. Replies
    8
    Views
    1,508

    Is this a steady state number? Whats your o2 and...

    Is this a steady state number? Whats your o2 and co2 readings? Recheck orifaces, double triple check that. I wouldnt think the flue pipe would be causing a high co reading.But you should get the...
  34. Replies
    8
    Views
    1,508

    Whats the reading?

    Whats the reading?
  35. Replies
    19
    Views
    2,301

    Clean the crossover and oriface again.Also take...

    Clean the crossover and oriface again.Also take the manifold off and clear that as well.If three are lighting i would def have to say spider web causing issues with light off intermittantly.Just...
  36. Replies
    42
    Views
    4,451

    :limb:

    :limb:
  37. Replies
    42
    Views
    4,451

    Wouldnt it be the other way around though??...

    Wouldnt it be the other way around though?? Higher the resistance higher amp draw?
  38. Replies
    41
    Views
    4,384

    Combustion analyzer or uni bit and camera looking...

    Combustion analyzer or uni bit and camera looking down.
  39. Replies
    23
    Views
    2,200

    In on this too.Thinking of making the plunge for...

    In on this too.Thinking of making the plunge for awhile now.
  40. Replies
    40
    Views
    7,423

    I can only attest to the 550's.Bought a set this...

    I can only attest to the 550's.Bought a set this past spring and really liked them.The way it was configured and layout made it real easy to use.Only drawback for me was the hook, i like to hook it...
  41. Replies
    42
    Views
    4,451

    Good info there. Is this for just carbide...

    Good info there. Is this for just carbide ignitors or nitrides as well?
  42. Replies
    42
    Views
    4,451

    And then it fails a month after your maintenance...

    And then it fails a month after your maintenance call?? For carbides (flat nortons and such) on a cold ignitor anything over 80 ohms i recommend replacement. I dont like going back to a cust house i...
  43. Replies
    23
    Views
    1,371

    My D-tec works well on blends as well.

    My D-tec works well on blends as well.
  44. Replies
    35
    Views
    3,502

    So the board had an internal short? Does it have...

    So the board had an internal short? Does it have a good ground? Whats the amp draw of the valve?
  45. Replies
    4
    Views
    655

    Thanks for the reply mike.I was reading some of...

    Thanks for the reply mike.I was reading some of your posts and was going to pm you directly.Glad you chimed in.Thanks helps alot.
  46. Replies
    4
    Views
    655

    Thermopile question

    Whats the best way to check a closed reading on a thermopile? Have a gravity with a 700 mv "open" reading. And what is a good "closed" reading on a 750??
  47. We did air duct cleaning for years.We used a...

    We did air duct cleaning for years.We used a biltmore truck and a Viper clean sweep.The kit (Viper) was pretty nice it came with everything needed, rods (rigid and flex) Reverse & forward balls and...
  48. Replies
    8
    Views
    1,252

    I use a testo 550 and use two sets of hoses. And...

    I use a testo 550 and use two sets of hoses. And if i run into a 410 i purge nitrogen before use to make sure.
  49. Replies
    26
    Views
    1,978

    Sounds like your possibly overcharged tryin to...

    Sounds like your possibly overcharged tryin to start against a high head.Whats the static pressure idle? I think you need to check your statement here.:whistle:
  50. Thread: Veto Rocks!

    by atoztech
    Replies
    2
    Views
    923

    After all the rave reviews on here and checking...

    After all the rave reviews on here and checking them out on youtube bought my first Veto a couple days ago.Got the Lc and cant wait to get my hands on it.The warranty the customer service and the...
Results 1 to 50 of 74
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event