  1. Thread: Tor-Rey

    by A1 Burt
    Replies
    8
    Views
    491

    HAD TO CHANGE A CONDENSOR FAN MOTER NOT FUN

    HAD TO CHANGE A CONDENSOR FAN MOTER NOT FUN
  2. Replies
    1
    Views
    344

    ohm out fan cycling switch & low pressure for...

    ohm out fan cycling switch & low pressure for continuity & grounded
  3. Replies
    5
    Views
    475

    a liquid cooled condenser.

    a liquid cooled condenser.
  4. Replies
    16
    Views
    881

    AIR FLOW ?

    AIR FLOW ?
  5. Replies
    15
    Views
    927

    clean the water side of the machine then clean...

    clean the water side of the machine then clean the air side of machine it would be nice if I knew what type machine it is good luck
  6. mike . let one of your h-v-a-c guys build some...

    mike . let one of your h-v-a-c guys build some thing with you when you get back home .good luck.
  7. Thread: Adding R404a

    by A1 Burt
    Replies
    72
    Views
    4,309

    TROLL---TROLL---TROLL

    TROLL---TROLL---TROLL
  8. Thread: Adding R404a

    by A1 Burt
    Replies
    72
    Views
    4,309

    look at the liqed reciver find the sight glasses...

    look at the liqed reciver find the sight glasses should be maybe 4 or 5 bring leavel up to 1st or2nd sight glass then open some walk in cooler & frezer doorsleve them open for a little while maybe...
  9. Replies
    23
    Views
    2,904

    "THIRD WORLD"

    "THIRD WORLD"
  10. Replies
    2
    Views
    350

    since you took X- term off timer just reduce...

    since you took X- term off timer just reduce amount of time on each defrost . get the right fan delay - termator switch hook it up right put defrost time back to were it was . be done with the call .
  11. Replies
    14
    Views
    2,323

    the garden hose must be used for a drain line on...

    the garden hose must be used for a drain line on one of those hook up some where . it was there so lets use that old suction line we can save a lot of money .
  12. i take care of a 1200 modle and thay got it used...

    i take care of a 1200 modle and thay got it used frist thing i had to fix was t-x-v only one was bad but did both any way . about 5 years latter one went bad this time only changed one valve the...
  13. Replies
    52
    Views
    4,075

    this store has one that i think is a 1962 this is...

    this store has one that i think is a 1962 this is ser# w-62A-19067 that one is for a walk in it still has R-12 This other one is for a produce case G-62D-08436 both are 3 phase
  14. mike I had to see where you were from . I have a...

    mike I had to see where you were from . I have a diner with the same ding's I think they used a meat clever It is amazing the thing still drop's ice
  15. Thread: TXV adjustment

    by A1 Burt
    Replies
    17
    Views
    1,286

    temp control ? L.P.C. ? check them out

    temp control ? L.P.C. ? check them out
  16. superheat=temperture on suction line next to...

    superheat=temperture on suction line next to sencing bulb- then get a presure reading next to sencing bulb convert to temp from a pressure - temperature chart subtrack the two numbers then you will...
  17. Replies
    5
    Views
    530

    1938 frigidaire

    compressor had a lose wire on middle post tighten it up all good . happy camper
  18. Replies
    48
    Views
    5,518

    on simi hermetic where wire hook up to termanile...

    on simi hermetic where wire hook up to termanile post if you see oiley resadew in side when you take cover off there you go be careful when tightening up post!!!
  19. G-E used the stuff as a refrigerant for 18 months...

    G-E used the stuff as a refrigerant for 18 months then stoped methylformate was used in nerve gas .
  20. the C-A modle had METHYL FORMATE in them...

    the C-A modle had METHYL FORMATE in them bad stuff stay away !!!!!!!!!!!!
  21. Thread: Short Cycle

    by A1 Burt
    Replies
    21
    Views
    1,660

    power head on t-x-v ?

    power head on t-x-v ?
  22. Replies
    8
    Views
    2,142

    bradleyshermetics.com I got 3 of them & sight...

    bradleyshermetics.com I got 3 of them & sight glass & o rings & gaskets
  23. Thread: made in china

    by A1 Burt
    Replies
    4
    Views
    699

    bunny that is about right

    bunny that is about right
  24. Thread: made in china

    by A1 Burt
    Replies
    4
    Views
    699

    made in china

    are some manitowoc ice machines made in china ?
  25. Replies
    40
    Views
    4,502

    check hot gas valve for leek

    check hot gas valve for leek
  26. Replies
    7
    Views
    947

    BACK SEAT ?

    BACK SEAT ?
  27. Replies
    22
    Views
    3,181

    Refrigeration hardware supply corporation #...

    Refrigeration hardware supply corporation # 800-716-6655
  28. Replies
    20
    Views
    1,174

    look around the where evaportor is & look for...

    look around the where evaportor is & look for lowest place is 7 THERE MIGHT be a acces fitting there then you are in luck or call thermol king & ask them the way & what to look out for good luck
  29. Replies
    20
    Views
    1,174

    check 3 way valve thay hang up betwen cool mode ...

    check 3 way valve thay hang up betwen cool mode & hot gas mode I don't work on that type any more don't have the patincens for it call THOMAL KING for trubble shooting book's good luck
  30. Replies
    20
    Views
    1,174

    no what i ment was what type of unit is it MAKE...

    no what i ment was what type of unit is it MAKE -MODEL -SERIAL basically more information
  31. Replies
    20
    Views
    1,174

    what is a c-p-c unit?

    what is a c-p-c unit?
  32. Replies
    20
    Views
    1,174

    IS YOUR TEMP CONTROLL THE TYPE THAT THE END OF...

    IS YOUR TEMP CONTROLL THE TYPE THAT THE END OF THE PROB GO'S IN THE COIL ? MAYBE IT IS AND IT IS NOT SO IT IS GETTING AIR TEMP NOT SHUTTING SYSTEM OFF FLODDING BACK washing oil out of compressor...
  33. Replies
    20
    Views
    1,174

    do you have an E-p-A 608 CARD ?

    do you have an E-p-A 608 CARD ?
  34. Replies
    20
    Views
    1,174

    was system set up with low pressure controll with...

    was system set up with low pressure controll with the differential set to close ? it sound's a lot of short cycling & very high supper heat= cooked oil
  35. Replies
    13
    Views
    1,559

    if you can front seat suction valve and see how...

    if you can front seat suction valve and see how low it will go and then see how long it stay's there that should give you some idai of what might be happen good luck
  36. Replies
    8
    Views
    1,689

    go to school and learn what you can learn take...

    go to school and learn what you can learn take test get E-P-A card learn more in the field then answer your own question O-K
  37. TRY TO CHANGE CAP TUBE MAKE IT THE RIGHT SIZE...

    TRY TO CHANGE CAP TUBE MAKE IT THE RIGHT SIZE CHANGE DRYER LEEK TEST PULL VACUUM ADD GAS GET SYSTEM WORKING RIGHT THEN KICK BACK AND HAVE SOME ICE CREAM
  38. Thread: bev air t-17

    by A1 Burt
    Replies
    4
    Views
    641

    SYSTEM RUNNING IN A VACUUM = NOT PUMPING

    SYSTEM RUNNING IN A VACUUM = NOT PUMPING
  39. Replies
    4
    Views
    846

    make it a pump down system & dont worry about C-I...

    make it a pump down system & dont worry about C-I & C-O
  40. Replies
    8
    Views
    647

    the temp controll is coil or air ? why didnt you...

    the temp controll is coil or air ? why didnt you check to see if tempcontroll was open ? befor putting a pericing valve on system
  41. Replies
    18
    Views
    1,190

    icemeister good question I did not come up with...

    icemeister good question I did not come up with the right answer but I did learn from it like I do from this forum all the time keep posting mystery diagnosing . thank's
  42. Replies
    18
    Views
    1,190

    compressor hot from lose plug in G-f-I AFTER IT...

    compressor hot from lose plug in G-f-I AFTER IT COOLED FOR 15 MINUTES THERMAL OVER LOAD RESET & there you go
  43. Replies
    2
    Views
    661

    the 115 - v to 12 -v transformer burnt up

    the 115 - v to 12 -v transformer burnt up
  44. Replies
    2
    Views
    661

    traulsen model G22010

    is this box one of those box's that just has problems with the defrost modular & 115-V A-C to 12 V the one that I looked at to day the owner told me that this will be the third one for this box...
  45. Replies
    1
    Views
    392

    some times it is good for a laugh some times you...

    some times it is good for a laugh some times you ask your self am i in a third world country check every thing BE SAFE good luck
  46. Thread: drop to day

    by A1 Burt
    Replies
    6
    Views
    890

    did you put system together ? check if...

    did you put system together ? check if restrictor was or was not put in
  47. Replies
    13
    Views
    1,420

    was the system flooding back ?

    was the system flooding back ?
  48. Replies
    2
    Views
    852

    thank you ice meister that is very helpful have a...

    thank you ice meister that is very helpful have a happy & safe holiday
  49. Replies
    2
    Views
    852

    T-X-V Distributor nozzle

    Is there a chart for different size nozzles for different tonnages?

    Thank you.
  50. Thread: old hat

    by A1 Burt
    Replies
    8
    Views
    562

    thank you all for your input. I am not sure...

    thank you all for your input. I am not sure what is ment by the term HALF WINDING
Results 1 to 50 of 203