  1. Replies
    11
    Views
    1,177

    Click on the LGR in sitebuilder, and it's a...

    Click on the LGR in sitebuilder, and it's a option. Should be failry intuitive.
  2. Replies
    11
    Views
    1,177

    Go to the LGR you want to set as a BBMD. It'll...

    Go to the LGR you want to set as a BBMD. It'll only make that one a BBMD.
  3. Replies
    11
    Views
    1,177

    I'm pretty sure it'll cause a parameter mismatch,...

    I'm pretty sure it'll cause a parameter mismatch, but you can try manual command "BBMD SET".
    I've always done it in Sitebuilder.
  4. Replies
    11
    Views
    1,177

    In Sitebuilder.

    In Sitebuilder.
  5. The latest SAL file I know of is...

    The latest SAL file I know of is alc-6.0-20150209. It's included with 6.5.
  6. Replies
    13
    Views
    701

    You should be able to write to BV:2008 on v3. ...

    You should be able to write to BV:2008 on v3.

    http://hvac-talk.com/vbb/attachment.php?attachmentid=701891&d=1466617302&thumb=1&stc=1
  7. Replies
    55
    Views
    4,054

    Most reasonable people know lon is all but dead....

    Most reasonable people know lon is all but dead. But I get what your doing..please carry on.
  8. Replies
    5
    Views
    587

    Are they ZN341 or U-341...legacy (exec6) or...

    Are they ZN341 or U-341...legacy (exec6) or execb? Why rip out WebCTRL ? Leave it running in the background so future programming can be done.
  9. Replies
    30
    Views
    2,385

    Try using compatibly mode in IE

    Try using compatibly mode in IE
  10. Replies
    2
    Views
    218

    If you have the the LX5 your in luck. LX5 still...

    If you have the the LX5 your in luck. LX5 still All the software you need is available free online. The LX6 needs the full Eikon and special cables.
    The E-Link simply converts the RS485 wiring to...
  11. Replies
    9
    Views
    1,060

    How do you say pink slips in chinese?

    How do you say pink slips in chinese?
  12. Replies
    6
    Views
    561

    I second Onicon. They just work IF setup and...

    I second Onicon. They just work IF setup and installed correctly.
  13. Replies
    8
    Views
    4,221

    Not sure what you mean by all alarm types. Most...

    Not sure what you mean by all alarm types. Most modern control front ends have no issues setting up alarms from 3rd party's.
  14. Replies
    15
    Views
    1,390

    I would tend to agree after living here for 12...

    I would tend to agree after living here for 12 years. High cost of living and the 2-3+ hours of daily driving sucks the life out of you. But $100k + pension make up for a lot of bravo sierra.
  15. Replies
    10
    Views
    489

    If price is no option, stay with pneumatics and...

    If price is no option, stay with pneumatics and E/P's. They will outlast any electronic actuator. Use spring return actuators that return to fail safe position. In fact I just had a critical bypass...
  16. Replies
    32
    Views
    1,535

    We only use Lon on existing jobs and even that is...

    We only use Lon on existing jobs and even that is getting rare. I see more modbus and SNMP then LON these days. It ain't going away, but it's fading fast.
    I'ld say 98% Bacnet.
  17. Your right it's a b*tch. Most the time I used...

    Your right it's a b*tch. Most the time I used SquareD driver. Please keep in mind this ALC and NOT Tridium, but it still should work. When I get a chance I'll see how I did it with Modbus. I know it...
  18. I was refering to the FB's or .equipment files....

    I was refering to the FB's or .equipment files. Some of the original programs has calculation errors and/or conversion errors. For example, the output my water meters need to be multiplied by 60!
  19. I wish you luck. Do what MaxBurn says, but don't...

    I wish you luck. Do what MaxBurn says, but don't let the Admin account expire. Also use the newest ER programs you can find.
  20. Never had an issue. Tied into a lot of them over...

    Never had an issue. Tied into a lot of them over the years.
  21. Replies
    1
    Views
    323

    Verizon Strikes Again

    FYI..Verizon froze some accounts until you respond to an email. Since we use it as a mail server, nobody ever looks at the emails in account. That is till it fails and you miss an alarm over the...
  22. Replies
    11
    Views
    927

    100+ in LA. I know guys that clear that in NYC,...

    100+ in LA. I know guys that clear that in NYC, and some.
  23. Replies
    7
    Views
    782

    Thanks for bad news. It seemed only a few years...

    Thanks for bad news. It seemed only a few years back that I had 4 different faded corporate logo's on my work Truck.
  24. Thread: BACscope

    by control$
    Replies
    9
    Views
    2,081

    Glad I'm not the only one doing Arcnet via USB....

    Glad I'm not the only one doing Arcnet via USB. Wonder why ALC stopped supporting Bacscope. I still find it better then Wireshark. Quirks and all.
  25. Thread: BACscope

    by control$
    Replies
    9
    Views
    2,081

    It's a little tricky getting rid of the polling,...

    It's a little tricky getting rid of the polling, and would recommend other options if your new to this.
    I'm surprised nobody jumped on me about the Arcnet statement.
  26. Thread: BACscope

    by control$
    Replies
    9
    Views
    2,081

    What are you looking to do with it? Not much use...

    What are you looking to do with it? Not much use on Arcnet without a Arcnet card. Works great on MS/TP. Hell I'm using it right now.
  27. Replies
    3
    Views
    364

    Not an option on the driver. It looks as if I...

    Not an option on the driver. It looks as if I have to physically go and plug in. I hope I can change it via hyperterm.
  28. Replies
    3
    Views
    364

    SitelinkE Device Instance

    Running WebCTRL 6.1 with a SitelinkE under the Arcnet..

    Why the f*ck is the Assigned device instance not the actual Device instance? Not getting alarms and loosing communication..My guess no...
  29. It's an over rated experience. 668091

    It's an over rated experience.



    668091
  30. My guess most of the system is in good shape? The...

    My guess most of the system is in good shape? The upgrade is easy and mostly painless in 90% of what I've done. I've noticed some button/switches on some graphics at some sites need to be redone to...
  31. Replies
    30
    Views
    2,385

    Nothing.

    Nothing.
  32. Replies
    25
    Views
    6,541

    How safe is say off the shelf Netgear VPN. I've...

    How safe is say off the shelf Netgear VPN. I've setup many sites and found it to be easy and quick once you get past the learning curve.
    The only problem is then you become the network admin IF you...
  33. Happen to have a MN-CIM converter. Haven't used...

    Happen to have a MN-CIM converter. Haven't used it in over 10 years
  34. Bacnet object identifier - Is it a...

    Bacnet object identifier - Is it a AI,AO,AV,BI,BO,BV,Trend,Loop and so on. Usually followed by a sequential #. (It tells you what the physical object is.) Physical Point Location - BO:4
    Object name...
  35. Legacy communications? Run requests???

    Legacy communications? Run requests???
  36. I'm living your union dream my friend and not...

    I'm living your union dream my friend and not saying it's bad, it ain't. It really depend on the company and people you work with. But if your good....your good. And your pay comes from your worth....
  37. Yep..Union dues are just great. Same pay except...

    Yep..Union dues are just great. Same pay except you get a "recommended" voting list filled with Liberals, Criminals and Communists.
  38. All that exec.6 software came with Supervision,...

    All that exec.6 software came with Supervision, maybe you'll find the old floppy's laying around. Don't even try installing it on a 64 bit machine.
  39. 10-4. I stopped doing it that way a long time...

    10-4. I stopped doing it that way a long time ago.. Not to pick, just a question. How would the interop conversion wizard create a .equipment file with the wrong fb?? WebCTRL would show it needing to...
  40. Why not just upload the .equipment file, rename...

    Why not just upload the .equipment file, rename it as a zip. Then extract the .fb...
  41. What is it are you looking to do? Modify the...

    What is it are you looking to do? Modify the logic or just open it?
    Exec 6? 4? 3????
    You'll need to do a few things before you open a legacy file.
    You need (3) programs FB pack, Legacy Eikon, and...
  42. Replies
    10
    Views
    1,493

    Have you restarted the service? Can you log into...

    Have you restarted the service?
    Can you log into SiteBuilder?
    How old is the install?
    If all else fails it must be sent to alc. No default passwords or backdoors exist.
  43. Replies
    6
    Views
    964

    The differences must be cosmetic. I understand...

    The differences must be cosmetic. I understand with superset now available everything must be compatible.
  44. Replies
    5
    Views
    1,053

    The admin-level password is defined in the...

    The admin-level password is defined in the screen-definition HTML file. Your best bet would be to call Seasons Four.
  45. Replies
    40
    Views
    5,379

    He can't mean under (1) bacnet to MS/TP network....

    He can't mean under (1) bacnet to MS/TP network. Do you mean under 150 routers and networks? That's only about 20 devices a MS/TP network.
  46. Replies
    12
    Views
    1,068

    Are the points check "network visible"? Can you...

    Are the points check "network visible"? Can you discover the ALC controls in you software?
  47. Replies
    12
    Views
    1,068

    When you look at the ALC logic, do you see your...

    When you look at the ALC logic, do you see your setpoints? What priority array are you writting to? ALC defaults to 16, you'll need to write at a lower value.
    What does "they will not stick" mean?
  48. Replies
    8
    Views
    1,334

    Something like this?...

    Something like this? http://www.automatedlogic.com/eikon-for-educators/%20/
  49. The only way it can be worse is if your told "We...

    The only way it can be worse is if your told "We are bidding the X project with X mechanical. Don't make them look bad." How the f*ck do you right up that ticket without looking like a tool.
  50. Don't tell me. It was wired to a CP8102 two input...

    Don't tell me. It was wired to a CP8102 two input control right? Kick a$$ electronic controls.