  1. Replies
    228
    Views
    43,712

    I, 2nd, that, EEI has a bunch of great guys ,I...

    I, 2nd, that, EEI has a bunch of great guys ,I worked for them over 4 years and only left cause of moving down south, today we still keep incontact and hoping soon they open a office close to...
  2. Replies
    45
    Views
    5,136

    just weigh in charge after vac ,pure liq. on...

    just weigh in charge after vac ,pure liq. on discharge side and let it set for a few min.best is to precharge ur hoses br haveing a yellow jacket shutoff valve at end of hose then read scales till...
  3. Replies
    14
    Views
    3,782

    coalescer filters are to slow oil from going out...

    coalescer filters are to slow oil from going out dish. side then a neddle valve returns it to the comp.
  4. Thread: On call pay

    by technut
    Replies
    82
    Views
    19,343

    4 hours min. for customers i love thunderstorms ...

    4 hours min. for customers i love thunderstorms 4 or 5 calls 4x5=20hours of work act work 4 hours
    and port to port.
  5. colonial webb industrial s.c. reviews.reply soon help

    I may make a change in employment to the ammonia refrigeration in s.c area with colonial webb just wanted some insight. anybody have anything good or bad to say will be helpfull, im not sure 60...
  6. Replies
    13
    Views
    2,056

    1. yes 2 not all systen has oil scrubbers i...

    1. yes
    2 not all systen has oil scrubbers i just use the liq pressure to push oil out never realy had a problem with doing my way. unless u got to keep smell down 1 account have heaters n the pots....
  7. Replies
    13
    Views
    2,056

    single stage low temp suction at 2 psig setpoint...

    single stage low temp suction at 2 psig setpoint frick micro rxf 151 screws.
  8. Replies
    13
    Views
    2,056

    I have a 5k plant that rsc build and does have a...

    I have a 5k plant that rsc build and does have a drier core piped in liq line with pypass system is about 13 years old.
    I think driers are better then nothing as long u blow out everything u work...
  9. Replies
    13
    Views
    2,056

    oil is thur out the system in sometimes u have to...

    oil is thur out the system in sometimes u have to pump out evap drain little oil out. mostly all the oil will lay at bottom of your system like oil pot. coalescers or oil separators not 100% eff,but ...
  10. Replies
    26
    Views
    6,791

    mor likely comp replacements every summer and no...

    mor likely comp replacements every summer and no relief
  11. Replies
    7
    Views
    1,056

    from southwestern ohio

    from southwestern ohio
  12. Replies
    7
    Views
    1,056

    i have all the skills and exp. with reta and up...

    i have all the skills and exp. with reta and up to date medical records fitness test we make 30 an hour first shift m-f. noway would i or any halfway good tech take that position
  13. Replies
    48
    Views
    3,466

    alot of times we would have to reengineer the bad...

    alot of times we would have to reengineer the bad engineering.
  14. Replies
    13
    Views
    3,525

    OEM, what came out, same will go in,...

    OEM, what came out, same will go in, refrigerant,parts,oils. always acid test.be safe.
  15. Replies
    47
    Views
    2,655

    im 35 been doing this for 17 years. right out of...

    im 35 been doing this for 17 years. right out of high school my uncle had me work under him.untill a buddy gave me a job in ammonia 10 years ago.
    I couldnt go thur all the leasons again if i started...
  16. Replies
    47
    Views
    2,655

    ok , guys I was wrong maybe 1 bad apple not...

    ok , guys I was wrong maybe 1 bad apple not enough to spoil all,lol.
    I know a person that tried to do this an older man that couldnt do much after a year of on the field exp. he was always stressed...
  17. Replies
    47
    Views
    2,655

    How old are u ? If over 35 theirs too much to...

    How old are u ? If over 35 theirs too much to learn its a diff. ball game ammonia.
  18. Replies
    13
    Views
    1,686

    thanks for reply fast

    thanks for reply fast
  19. Replies
    8
    Views
    1,537

    how much asking?

    how much asking?
  20. Replies
    13
    Views
    1,686

    I have to remove at times 300 hp motors(screws)...

    I have to remove at times 300 hp motors(screws) off ammonia compressors our service dept alway tied up taken boiler manhole covers off at some of our accounts.
  21. Replies
    13
    Views
    1,686

    I would like for u too email me or send pic and...

    I would like for u too email me or send pic and total weight have to be more then 5 ton cap. or more.
  22. Replies
    31
    Views
    3,785

    I can pretty much tell its a h/o job. thats why...

    I can pretty much tell its a h/o job. thats why most of our parts cost so much from mfg cause of this crap that the mfg has to mark-up on sells. Its hard to get the job when parts are taken out of...
  23. Thread: looking a/h

    by technut
    Replies
    0
    Views
    327

    looking a/h

    looking 4 air handdler 3 ton drive.to replace my own at home
  24. Thread: Vvt

    by technut
    Replies
    5
    Views
    638

    the carrier's virson back in the 1986. its been...

    the carrier's virson back in the 1986. its been awhile ago but the new building ownners just bought 10 r.t.u s starting to have problems with controls and knew that controls should b updated with new...
  25. Thread: Vvt

    by technut
    Replies
    5
    Views
    638

    generation 2, lol,lol

    generation 2, lol,lol
  26. Thread: Vvt

    by technut
    Replies
    5
    Views
    638

    i been trying to get some infro on them u know...

    i been trying to get some infro on them u know any link should would help.the old generation 2 vvt stat and vdt dampers carrier dont make any more and as the system get older as this 1 at 20 years...
  27. Thread: Knoxville Tn

    by technut
    Replies
    4
    Views
    730

    thinking about moving down around tenn or n.c....

    thinking about moving down around tenn or n.c. how is it with a universal epa card for servicing equipment chiller and rtu's
  28. Replies
    11
    Views
    1,106

    yes

    yes
  29. Replies
    1
    Views
    756

    ques.1 pump pressure should stay around 40 or no...

    ques.1 pump pressure should stay around 40 or no higher then 60 psi.
    2 Energize emergency pump
    3 Manually adjustable pressure reducer can go to what 15% of maximum
    allowable working...
  30. Replies
    136
    Views
    18,393

    that's wierd I'm not familiar with how the...

    that's wierd I'm not familiar with how the licincing works in the states buy you say journeyman cert for refrig is no good for ammonia work??

    r-717 ammonia is in a class of its own. 1- u cannt use...
  31. same here but 1 problem is I wish this could b in...

    same here but 1 problem is I wish this could b in the proforms for only cause of the rules going in detail of equipments/servicing
  32. Thread: food racks

    by technut
    Replies
    1
    Views
    1,752

    food racks

    Ok Im starting a new job with another commercial company and I have never worked or saw a rack system.The boss told me that with my exp. that I would catch on quick.
    I need any infor. that any body...
  33. Replies
    136
    Views
    18,393

    yeah the high tonnage chiller guys are definatly...

    yeah the high tonnage chiller guys are definatly a special breed they are well paid but it also takes a long time to become an 'experienced' tech. as well as the big chiller guys the ammonia dudes...
  34. Replies
    58
    Views
    14,274

    I was on the trane project is just what...

    I was on the trane project is just what esornivram is talking about,I agree 100%.
  35. Thread: resi to comm

    by technut
    Replies
    13
    Views
    1,362

    I've done industrial ammonia r-717 for about 5...

    I've done industrial ammonia r-717 for about 5 years and have RETA-CER.
    got the call from this sevice company for commercial work.Boss told me if i could do the industrial (ammonia) I could do this...
  36. Thread: Novar

    by technut
    Replies
    8
    Views
    1,133

    1 thing i forgot make sure the compressor lockout...

    1 thing i forgot make sure the compressor lockout is at 50 to 60 f. and outside bulb sensor not bad.
  37. Thread: Novar

    by technut
    Replies
    8
    Views
    1,133

    A lot of times the store manager will clear roof...

    A lot of times the store manager will clear roof access alarms and u should always asked if your rtus are alarmed ( they should only be alarmed if in case of fire)and if so could they put them on...
  38. Replies
    198
    Views
    65,783

    I Dont Use A Bag And Would Not As An Commercial...

    I Dont Use A Bag And Would Not As An Commercial Tech.i Use A Bucket And Dolly, 2 In 1 System. Sometimes I Like To Have A Seat To Save My Knees
  39. Thread: cordless drill

    by technut
    Replies
    19
    Views
    2,206

    i have a 14.7 volt bosh its the smallest cordless...

    i have a 14.7 volt bosh its the smallest cordless drill i ever had.I do all commercial work and its worth the 124. with lifetime warry.their is no place i cannt drill and very easy to fit in bucket,i...
  40. Replies
    161
    Views
    55,073

    I have always pulled from both sides and finished...

    I have always pulled from both sides and finished by pulling from suction port in the last few min. of vac.
  41. Replies
    8
    Views
    985

    what the hell if you dont know the basic then you...

    what the hell if you dont know the basic then you need to start studing.
  42. Replies
    10
    Views
    5,142

    is this unit txv or fixed? I would add fac....

    is this unit txv or fixed? I would add fac. spec.charge and check amp draw on compressor should be 5 amps below RLA.or around ballpark, low amp draw would tell me compressor under charge. too much...
  43. Replies
    25
    Views
    3,974

    I still have some left,email me at **put it in...

    I still have some left,email me at **put it in your profile** with your number so we can make arrangments.

    [Edited by arpa on 11-14-2006 at 07:53 PM]
  44. Replies
    25
    Views
    3,974

    They do contain acetylene.I do travel around...

    They do contain acetylene.I do travel around tri-state,ind,ohio,ky. all over I could deliver or meet half way.or sell and deliver empty's.it all depends were u at.
  45. Replies
    25
    Views
    3,974

    thats crazy,man.

    thats crazy,man.
  46. Replies
    25
    Views
    3,974

    I dont know the history but I know of diff. in...

    I dont know the history but I know of diff. in connection of the 2 types
  47. Replies
    25
    Views
    3,974

    I'm sorry guys, I mean that they were the same...

    I'm sorry guys, I mean that they were the same size as the other B-TANK that r for sale.
  48. Replies
    25
    Views
    3,974

    it's not mc tank connection.

    it's not mc tank connection.
  49. Replies
    25
    Views
    3,974

    b-tank for 30.00 each, some are full.I only have...

    b-tank for 30.00 each, some are full.I only have 6 full and the rest r empty .will give the full ones frist for no extra cost. The tanks are the same as the other guys on tool topic.
  50. Replies
    49
    Views
    5,304

    mardoman, I second that.I think that you would be...

    mardoman, I second that.I think that you would be ok with the fix orfices.
Results 1 to 50 of 298