  1. Replies
    9
    Views
    298

    I agree. it look like they really take time to...

    I agree. it look like they really take time to remove those control board and they took the gas valve too.
    i am sure you need to spend some time to loose up the gas valve....
  2. Replies
    9
    Views
    298

    i have send you a Private Message. it is my...

    i have send you a Private Message. it is my email address
  3. Replies
    9
    Views
    298

    I took out the back side panel which i can see...

    I took out the back side panel which i can see the heat exchanger completely.
    it is still in good shape
  4. Replies
    9
    Views
    298

    No, i don't see any sign of fire or burn mark. ...

    No, i don't see any sign of fire or burn mark.
    all the wires are cut and missing
  5. Replies
    9
    Views
    298

    Wiring diagrams for Trane

    I got a service call today, which heat is not working.
    I went up to the roof top and i see all the panel and cover are missing on the Trane unit.
    When i look closer, i found out not only the...
  6. Replies
    12
    Views
    491

    Alamo, i would like to have the manual. Thank...

    Alamo, i would like to have the manual.
    Thank you for your help once again
  7. Replies
    12
    Views
    491

    Thank you so much, Alamo this is the right one,...

    Thank you so much, Alamo
    this is the right one, i can't believe that i really have to remove the coil to replace the fan motor.
    Thank you for your help
  8. Replies
    12
    Views
    491

    that is not the same GE refrigerator. this is...

    that is not the same GE refrigerator.
    this is the Model #psb42ysxass
  9. Replies
    12
    Views
    491

    that is correct, 2 coils and 2 fan motors. one...

    that is correct, 2 coils and 2 fan motors.
    one of freezer side, one of fresh food side.
    i am trying to replace the one on the freezer side
  10. Replies
    6
    Views
    484

    where is the 2653 come from?

    where is the 2653 come from?
  11. Replies
    12
    Views
    491

    There is a access at the fresh food side? Not...

    There is a access at the fresh food side? Not the freezer side?
  12. Replies
    12
    Views
    491

    I reach the evaporator bracket and the line set...

    I reach the evaporator bracket and the line set is attached to it. It is very easy to bent the line set, therefore i stop removed the bracket.
    This refrigerator is bulid-in kind. Very hard to pull...
  13. Replies
    12
    Views
    491

    GE refrigerator fan motor

    Have anyone work on GE refrigerator Model#psb42ysxass
    i am trying to replace evaporator fan motor on the freezer side.
    i have removed almost everything inside out, ice maker, cables,...
  14. Replies
    31
    Views
    1,262

    All of you think his idea is not going to work,...

    All of you think his idea is not going to work, then i guess we have to come back to work on it again somehow.....
    Lets wait and see.........
  15. Replies
    31
    Views
    1,262

    I was shock that johnstone did not have it in...

    I was shock that johnstone did not have it in stock.
    We have to wait for 3 days. Then my co worker got this idea in his head
  16. Replies
    31
    Views
    1,262

    Both compressor are 8500 BTU, i don't know about...

    Both compressor are 8500 BTU, i don't know about the temp rating for those compressor.
  17. Replies
    31
    Views
    1,262

    If i have increase the size of the cap tube,...

    If i have increase the size of the cap tube, would that be working?
    Or, if i really want to play with remodel the unit, i can add a TXV to make it work?
  18. Replies
    31
    Views
    1,262

    The reach in cooler is cooler OK for now. The R22...

    The reach in cooler is cooler OK for now. The R22 compressor is running, however it is running on very high head pressure. it is on 270 psi.
    base on what i usually see on those similar reach in,...
  19. Replies
    31
    Views
    1,262

    since R22 is a higher temp than R134a, i believe...

    since R22 is a higher temp than R134a, i believe the head pressure will be higher.
    The condenser coil size should be different too, otherwise the compressor might overheat.
    That is what i think.
  20. Replies
    31
    Views
    1,262

    The head pressure is a bit higher but i think...

    The head pressure is a bit higher but i think maybe because of the different freon
  21. Replies
    31
    Views
    1,262

    Compressor replacement with different freon

    Me and my co worker are working on a reach in cooler today.
    It is a 1/3HP, 134a and 115v compressor. The R is shorted to the ground.
    The new compressor need 3 days to order, therefore my co...
  22. Replies
    3
    Views
    876

    Fresh air intake???

    Fresh air intake???
  23. Replies
    54
    Views
    1,890

    I found out more story this clogged up freezer....

    I found out more story this clogged up freezer.
    Someone inject super seal in this freezer 1 week ago.
    Can those woodchips be the reaction of the moisture?
    Wow.... i start to wounder if the...
  24. Replies
    54
    Views
    1,890

    They look like wood chips..... anybody have any...

    They look like wood chips..... anybody have any ideas?
    After i replaced the head master, the unit is back to normal.
    I did not know if the head master is clogged, then i don't have enough to feed...
  25. Replies
    54
    Views
    1,890

    OK, Guys When i cut the line connect to the head...

    OK, Guys
    When i cut the line connect to the head master, i found the pipe is clogged with all these tiny piece. It is inside the head master, inside the coils and i have no idea what are those!!!
    I...
  26. Replies
    32
    Views
    1,413

    I have used the super seal 3 times on 3 different...

    I have used the super seal 3 times on 3 different DX unit.
    They are all failure after 2 weeks. All compressor locked up!!!!
    I am not going to use the super seal anymore.
    I also wonder this item...
  27. Replies
    19
    Views
    705

    i removed the water pan and pull down the pump

    i removed the water pan and pull down the pump
  28. Replies
    19
    Views
    705

    it is stucked very badly and i don't want to pull...

    it is stucked very badly and i don't want to pull too hard.
    i might break the water pan
  29. Replies
    54
    Views
    1,890

    is there a way to diagnose the headmaster?

    is there a way to diagnose the headmaster?
  30. Replies
    21
    Views
    1,222

    I saw more of my co-worker are doing the vacuum...

    I saw more of my co-worker are doing the vacuum without a micron gauge.
    most of them are ok without it. some of them have differ point of views.
    As what i learned when i was in school, vacuum...
  31. Replies
    54
    Views
    1,890

    you mean i can adjust the headmaster as the same...

    you mean i can adjust the headmaster as the same way as the TXV?
    which i can turn all the way open or all the way closed?
  32. Replies
    19
    Views
    705

    I finally got it out. Thank you so much guys!!

    I finally got it out.
    Thank you so much guys!!
  33. Replies
    54
    Views
    1,890

    i have charge more 404a on it and the glass is...

    i have charge more 404a on it and the glass is still not clear.
    actually, the glass always have bubbles on it.
    is there a way to diagnose the headmaster??
  34. Replies
    54
    Views
    1,890

    Superheat and subcooling are both very very high....

    Superheat and subcooling are both very very high.
    subcooling is 70.
    there is no crankcase pressure regulator and no pressure limiting TXV also
  35. Replies
    19
    Views
    705

    i keep push in and push in, i can move up and...

    i keep push in and push in, i can move up and down and turn right and left, but i still can pull the whole pump out.
  36. Replies
    54
    Views
    1,890

    i put the bulb on the aside ( not top or bottom),...

    i put the bulb on the aside ( not top or bottom), the unit is originally with 404a
  37. Replies
    54
    Views
    1,890

    I try to charge more 404a, then the head pressure...

    I try to charge more 404a, then the head pressure is about to reach 400 psi, then the high pressure control switch cut off.
  38. Replies
    54
    Views
    1,890

    i have charge 4 lbs on it. Still have bubble on...

    i have charge 4 lbs on it. Still have bubble on the sightglass.
    the conderser is clean , the fans are good. however my high side is very hot the whole time. Even the inlet of the TXV is hot
  39. Replies
    54
    Views
    1,890

    i got the exact replacement TXV.

    i got the exact replacement TXV.
  40. Replies
    19
    Views
    705

    Do you mean the white mount outside of the motor?

    Do you mean the white mount outside of the motor?
  41. Replies
    21
    Views
    1,222

    That is a good one. I will keep both side open...

    That is a good one.
    I will keep both side open for sure
  42. Replies
    19
    Views
    705

    if i have the space... i will hit it damn hard

    if i have the space... i will hit it damn hard
  43. Replies
    21
    Views
    1,222

    the best way to pulling a vacuum

    what is the best way to pulling a vacuum on a AC system?
    more than 1 pump at the same time?
    put it down to 500?
    micron gauge on each pump?
    Share your idea
  44. Replies
    19
    Views
    705

    damn it.... it is still unable to remove....

    damn it.... it is still unable to remove....
  45. Replies
    54
    Views
    1,890

    i touch the bypassing tube, inlet is very very...

    i touch the bypassing tube, inlet is very very hot. Outlet is ok to touch
  46. Replies
    19
    Views
    705

    Thank Mike, i am going to pull it a bit harder...

    Thank Mike, i am going to pull it a bit harder now.
  47. Replies
    19
    Views
    705

    i try to push down and pull the whole pump. i...

    i try to push down and pull the whole pump.
    i also try push down and turn left or right.
  48. Replies
    19
    Views
    705

    Manitowoc water pump replacement

    I have a water cooled Manitowoc Model SY0605W.
    The water pump is burned and smoking.
    I have the new water pump Model 82-5210-9 already. However, i can not find any mount or screw around the water...
  49. Replies
    54
    Views
    1,890

    The tube is size 3/8 to the headmaster. is it...

    The tube is size 3/8 to the headmaster.
    is it possible to clogged up ?
  50. Replies
    54
    Views
    1,890

    I will use the water hose on the condenser coil...

    I will use the water hose on the condenser coil tomorrow.
    Thanks