Search:

Type: Posts; User: La Air Man

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. When putting the male adapter for the drain make...

    When putting the male adapter for the drain make sure that the fitting is not too big to fit through the hole in the panel. The fitting we buy are too big so I just drill the hole a little bigger....
  2. I just remove it. Very easy.

    I just remove it. Very easy.
  3. Replies
    18
    Views
    1,214

    It was in a bulletin I got in the mail from my...

    It was in a bulletin I got in the mail from my distributor. It also had something about putting a float switch on one of the air handlers would cause problems with trips in the horizontal position....
  4. Replies
    18
    Views
    1,214

    Not supposed to use the charge assist with the...

    Not supposed to use the charge assist with the tam8. The bulletin that was sent to me said it will overcharge them. I checked with our rep about a job with an 1 1/8 lineset that had 22 feet vertical...
  5. Replies
    25
    Views
    3,707

    Are they using flex range connectors to tie into...

    Are they using flex range connectors to tie into the units?
  6. Replies
    24
    Views
    3,775

    Sure is.lol. I promise they're not all like that...

    Sure is.lol. I promise they're not all like that around here, but I sure do see my share.
  7. Replies
    8
    Views
    1,386

    Are they using the brooms and mops to adjust the...

    Are they using the brooms and mops to adjust the airflow? Very nice.
  8. Replies
    24
    Views
    3,775

    Yep. This is definitely one of the best I have...

    Yep. This is definitely one of the best I have come across. He acted surprised when I told him that his duct work wasn't right. I'm sure the x-13 motor that's in the unit won't last long.
  9. Replies
    24
    Views
    3,775

    Textbook install

    368141368151
    Found this one tripping on low pressure. I don't know how it was leaking water into the building.
  10. Replies
    8
    Views
    1,432

    Electrical? Drain? Both?

    I guess you get what you pay for. Not to mention it's a 4 ton system on 1100 square feet.
  11. Replies
    2
    Views
    337

    Sounds good. Thanks!

    Sounds good. Thanks!
  12. Replies
    2
    Views
    337

    Xl16i pressure transducer.

    I'm about to replace a pressure transducer on a xl16i heat pump. Is there a shader valve under it or do I need to recover the refrigerant. Thanks in advance!
  13. Thread: Wifi stats

    by La Air Man
    Replies
    12
    Views
    1,968

    I talked to one of the guys at our distributor...

    I talked to one of the guys at our distributor today and he said they still have the monthly fee. I will talk to my sales rep and see if he knows anything about the fee.
  14. Thread: Wifi stats

    by La Air Man
    Replies
    12
    Views
    1,968

    Wifi stats

    I have a customer that wants wifi stats installed with his xl16i Trane heat pumps so he can control the temperature from his phone. Trane does have a few options on wifi stats, but I wanted to get...
  15. Replies
    31
    Views
    4,321

    Have you had any problems with the blocks?

    Have you had any problems with the blocks?
  16. Replies
    31
    Views
    4,321

    There are joints in the wall. I have never had...

    There are joints in the wall. I have never had one leak yet. Even if I ran rolled copper I would still put an elbow where it goes outside because I personally don't like the big swoop with the rolled...
  17. Replies
    74
    Views
    9,003

    I just picked up a replacement coil for a...

    I just picked up a replacement coil for a b3bm-060k and it was a standard tube/fin design. This will be the second coil replacement in this unit since 96. Are their higher seer air handlers going to...
  18. Replies
    2
    Views
    518

    Thanks.

    Thanks.
  19. Replies
    2
    Views
    518

    Any Difference?

    Any difference between the mars h10-pm and the bacharach h10-pm leak detector? I can get the mars locally, but want to make sure there is no difference.
  20. Replies
    10
    Views
    1,004

    If I'm not mistaken, to get true locked rotor...

    If I'm not mistaken, to get true locked rotor amps you need to get an amp reading of the run and start winding at the same time with a good run cap. With an actual locked rotor.
  21. Replies
    18
    Views
    2,186

    IMO, that air handler and a 3.5 ton outdoor unit...

    IMO, that air handler and a 3.5 ton outdoor unit are a crappy system matchup under most real world conditions, especially with a unit that is intolerant of liquid stacking in the condenser, like the...
  22. Replies
    18
    Views
    2,186

    Gam5036 can move 1205 cfm at .5 static. The ari...

    Gam5036 can move 1205 cfm at .5 static. The ari rating is at 1335 cfm. At .3 it can move 1301 cfm. I don't think it can do it with tight ductwork.
  23. Replies
    34
    Views
    2,512

    Yep. Plenty of horses and coona$$es around...

    Yep. Plenty of horses and coona$$es around here.lol
  24. Replies
    34
    Views
    2,512

    Its a small world lol. The weather has been in...

    Its a small world lol. The weather has been in the middle 80's for the last month or so, but it stayed pretty cool today. Just waiting on the heat.
  25. Replies
    34
    Views
    2,512

    Does it have a micro channel coil?

    Does it have a micro channel coil?
  26. Replies
    13
    Views
    2,205

    I think the Hyperion vs air handler will revert...

    I think the Hyperion vs air handler will revert back to constant cfm in the heating mode even if it is set on torque mode.
  27. Replies
    46
    Views
    4,780

    Sorry. I didn't think the original poster meant...

    Sorry. I didn't think the original poster meant it like that. Thought he meant coil cleaner in general. But I do understand that micro channel coils shouldn't be cleaned with chemicals.
  28. Replies
    46
    Views
    4,780

    We use coil cleaner all the time. I put it in the...

    We use coil cleaner all the time. I put it in the coil cleaning gun that you can set how strong it is mixed. For regular maintenance I use the 10 to 1 setting, and turn it up a little if it is really...
  29. Replies
    16
    Views
    1,663

    Also on some stats that can use batteries or hard...

    Also on some stats that can use batteries or hard wired, when the batteries are installed the time delay function is not used.
  30. Replies
    6
    Views
    818

    Going to have to be careful not to drop a...

    Going to have to be careful not to drop a screwdriver on those coils when working on the blower.
  31. Replies
    9
    Views
    1,535

    JB does. They don't look as nice as the Yellow...

    JB does. They don't look as nice as the Yellow Jacket.
  32. Replies
    34
    Views
    3,062

    Do you know the link to the thread? I would like...

    Do you know the link to the thread? I would like to read it. Now I have seen a few units that were frozen. I looked at the drier and the inlet was fine but the outlet was sweating(can't remember the...
  33. Replies
    74
    Views
    9,003

    HaHa. Completely agree on that one, but the...

    HaHa. Completely agree on that one, but the condenser coil on the coleman and on the trane xb300 look exactly the same. Are they made by each manufacturer or do they all purchase them from another...
  34. Replies
    31
    Views
    4,321

    Yes BDI is our distributor. What type of stands...

    Yes BDI is our distributor. What type of stands are yall using? Just curious because some of the metal stands we get around here are a little flimsy. Especially the ones that have to be put together....
  35. Replies
    74
    Views
    9,003

    I'm not a fan of the micro channel coils. I have...

    I'm not a fan of the micro channel coils. I have found many leaks in the condenser coils(mostly coleman trailer condensers). Time will tell.
  36. Replies
    31
    Views
    4,321

    http://trane.com/Residential/Downloads/Brochure/Ai...

    http://trane.com/Residential/Downloads/Brochure/AirHandlers/72-1267-04_web.pdf
  37. Replies
    31
    Views
    4,321

    Yes, blow thru coil. Very quiet units.

    Yes, blow thru coil. Very quiet units.
  38. Replies
    31
    Views
    4,321

    The Tam air handlers are really nice. I don't...

    The Tam air handlers are really nice. I don't like the way the low voltage ties in but other than that they are really nice. The eev really controlls the super heat better than the txvs. I find they...
  39. Replies
    31
    Views
    4,321

    Our code is R-6, but we mostly use R-8 ductwork.

    Our code is R-6, but we mostly use R-8 ductwork.
  40. Replies
    31
    Views
    4,321

    Thanks guys. No turning vanes in the return. It...

    Thanks guys. No turning vanes in the return. It is not very long. We have not tested the static on it yet(no power to the house yet), but will when it gets connected. The units are set on top of some...
  41. Replies
    48
    Views
    4,672

    I use the 5-2-1 and the TO5 kits. We use them on...

    I use the 5-2-1 and the TO5 kits. We use them on all recip compressors if the indoor has a hard shut off txv. Was recommended by a factory rep not to put them on a scroll unless having problems with...
  42. Replies
    31
    Views
    4,321

    New home units.

    A few units we recently finished installing in some new homes.
  43. Replies
    22
    Views
    2,064

    Check out this from JB. D10244 - 1/4" FEMALE...

    Check out this from JB.
    D10244 - 1/4" FEMALE SWIVEL COUPLER
  44. Replies
    32
    Views
    4,082

    Looks good. Do you set them on Torque or Constant...

    Looks good. Do you set them on Torque or Constant Cfm?
  45. I have seen some of the newer Lennox condensers...

    I have seen some of the newer Lennox condensers that use Interlink compressors have a feature that makes it stop pumping once the suction gets too low ( I think 20 psi ). I'm not sure who makes these...
  46. I have seen this on some of the commercial...

    I have seen this on some of the commercial systems. Are they starting to install this on residential?
  47. Replies
    53
    Views
    7,755

    Looks good man. Nice and neat. It must be nice to...

    Looks good man. Nice and neat. It must be nice to work on a system that you can get to all sides it. In my area they are either in an attic or in a closet that is not much bigger than the unit. Many...
  48. Replies
    31
    Views
    2,196

    Sorry. I just reread my post and I typed it...

    Sorry. I just reread my post and I typed it wrong. The lower the outdoor temperature the higher the superheat. (generally speaking).
  49. Replies
    31
    Views
    2,196

    One of the best ways to see how outdoor...

    One of the best ways to see how outdoor temperature will affect the superheat is to let the unit stabilize and get a superheat reading. Then block off some of the air flow through the condenser coil...
  50. Replies
    31
    Views
    2,196

    In general lowering the temperature of the indoor...

    In general lowering the temperature of the indoor air will lower the superheat, but the outdoor temperature will affect it in the opposite way. A low outdoor temperature will call for a lower...