  1. Replies
    8
    Views
    842

    It was barely visible on the mfgr's tag, but the...

    It was barely visible on the mfgr's tag, but the date-of-manufacture was "5-87"
  2. Replies
    8
    Views
    842

    I've never seen an insulated liquid line either. ...

    I've never seen an insulated liquid line either. I've never seen a line-dryer inside either -- does it make much difference where it goes, as long as it's present? The old unit was a 2.5 ton as...
  3. Replies
    8
    Views
    842

    Carrier 2.5 ton change out - How's it look?

    Carrier 2.5 ton change-out. My mother's 1987 "oil-drum" Carrier finially stopped working. Sorry for the links -- the "manage attachments" button won't upload anything for some reason. I welcome...
  4. Replies
    3
    Views
    160

    Testing 123...

    Testing 123
    http://drive.google.com/file/d/0B6dZ5_Y6NgVyMS1zWW5ZVlNZZmc
  5. Replies
    3
    Views
    160

    Test imbedding again......

    Test imbedding again...
    https://drive.google.com/file/d/0B6dZ5_Y6NgVyMS1zWW5ZVlNZZmc
  6. Replies
    3
    Views
    160

    https://drive.google.com/file/d/0B6dZ5_Y6NgVy...

    <img>https://drive.google.com/file/d/0B6dZ5_Y6NgVyMS1zWW5ZVlNZZmc</img>
    test imbedding
  7. Replies
    3
    Views
    160

    Testing the imbeedding of pictures...

    https://drive.google.com/file/d/0B6dZ5_Y6NgVyQnEzeHZERDhpVkk

    https://drive.google.com/file/d/0B6dZ5_Y6NgVyMS1zWW5ZVlNZZmc

    Enjoy....
  8. Replies
    16
    Views
    1,412

    Greetings; I've read that the reason why DIY is...

    Greetings; I've read that the reason why DIY is frowned upon, is mainly to avoid liability. This totally makes sense. For anyone who's willing to offer a few words of advice, how do we take a...
  9. Replies
    16
    Views
    1,412

    Thanks for the info -- If this doesn't work, I...

    Thanks for the info -- If this doesn't work, I promise to bring an HVAC person in to work on this --- I'd have no choice...

    -A
  10. Replies
    16
    Views
    1,412

    According to the documentation that was left...

    According to the documentation that was left behind with the AH, I removed the jumper between R and BK, then installed the Humid. controller there. I also jumped R and O. This is not correct? ...
  11. Replies
    16
    Views
    1,412

    OP here: Welp, I connected the Humidity...

    OP here: Welp, I connected the Humidity Controller according to the documentation, but it doesn't alter the behaviour of the AH at all. It doesn't spin down to low-fan while the tstat is calling...
  12. Replies
    16
    Views
    1,412

    OP here: I see. My tech documentation on the...

    OP here: I see. My tech documentation on the AH, says that "Humidistat will be installed between terminals R and BK - Also note that terminals R and O must be shorted for proper blower operation"....
  13. Replies
    16
    Views
    1,412

    OP here: Thanks -- so the only thing a...

    OP here: Thanks -- so the only thing a dehumidistat will do, is to force low-fan-speed when there's already an existing call for cooling? Will it turn on the compressor along with low-fan-speed...
  14. Replies
    16
    Views
    1,412

    How does dehumidification work with my AH?

    Greetings;

    With the technical docs that were left behind from my installer, I see that a humidistat can be installed to work with my system. It's not a seperate unit, but some function of the AH...
  15. Replies
    21
    Views
    1,315

    The one transformer in the A/C AH has a 3A fuse...

    The one transformer in the A/C AH has a 3A fuse on the 24v side, and the transformer for the heat (installed in 1963) has no fuse on the 24v side, except for the 15A breaker on the Primary (120VAC)...
  16. Replies
    21
    Views
    1,315

    FIXED! (I can't figure out why though, since it...

    FIXED! (I can't figure out why though, since it worked perfectly for 4 years then stopped..) I re-wired the two zone-valves, transformer, and tstats according to a diagram I found on Taco's...
  17. Replies
    21
    Views
    1,315

    OK - zone valve is rated for 24v and .9A. I...

    OK - zone valve is rated for 24v and .9A. I compared upstairs zone-valve, which works perfectly.

    Upstairs:
    25.1v coming from transformer
    dips to 21v when valve is opening, and is pulls .91A

    ...
  18. Replies
    21
    Views
    1,315

    'Fried' was my word I guess... What I've...

    'Fried' was my word I guess... What I've diagnosed, is that when the Tstat closes its relay, which should send 24v to the zone-valve; there's no voltage. If I bridge R and W on the Tstat, voltage...
  19. Replies
    21
    Views
    1,315

    Question: The "R" and "Rc" terminals on a Tstat...

    Question: The "R" and "Rc" terminals on a Tstat are where the 'hot' line from the transformer connects. Rc is power-for-cooling. Does this mean "R" is the power for heat? Is this how a Tstat...
  20. Replies
    21
    Views
    1,315

    the Tstat for downstairs is the one that died. ...

    the Tstat for downstairs is the one that died. The upstairs Tstat is a Honeywell item from ~2002 (programable), but it doesn't go 'click' when a call for heat is made. This older Tstat is working...
  21. Replies
    21
    Views
    1,315

    Fuse is still intact - I still see 28VAC at the...

    Fuse is still intact - I still see 28VAC at the Tstat. I could swap the two zone valves to see if the problem follows the valve - but that's an expensive fix; because it fries an $80 Tstat.

    For...
  22. Replies
    21
    Views
    1,315

    There's a 5A automotive-type fuse that powers the...

    There's a 5A automotive-type fuse that powers the transformer. I think I left something out -- when the Tstat calls for heat, and closes the ckt for heating, the current routes thru one of those...
  23. Replies
    21
    Views
    1,315

    Burning up a Tstat??

    Can I get a professional opinion? I've been running just fine for 4 years with a Honeywell CT3500 Tstat. Just before Christmas my furnace stopped coming on. I traced this to the fact that the...
  24. Replies
    27
    Views
    7,857

    The old boiler (from pics of the nameplate) ...

    The old boiler (from pics of the nameplate)

    Federal Boiler model GFS-17. AGA input 175K AGA output 140K net output 123K The house was built in late '64, into '65. Boiler was working fine --...
  25. Replies
    27
    Views
    7,857

    Question: That smaller horizontally-mounted...

    Question: That smaller horizontally-mounted expansion tank has wording on it, that says it's for domestic hot water expansion. BUT: The tank is definitly on the cold-water input to the tank. Do...
Results 1 to 25 of 160