  1. Replies
    6
    Views
    538

    I tried a 5 KW restring kit but wasn't able to...

    I tried a 5 KW restring kit but wasn't able to get it connected to the insulators in such a fashion that I felt comfortable with. I probably should have worked with that idea a little more than I...
  2. Replies
    6
    Views
    538

    I did not get the kit number as I thought the...

    I did not get the kit number as I thought the element would be fairly easy to get. This is a two element coil so what I have done while waiting, and to get some heat back, was to completely remove...
  3. Replies
    6
    Views
    538

    Hard to find TRANE part

    I am working on a TRANE residential heat pump that needs a replacement aux electric heating coil part no: HTR01780; 9.6 kw at 240 volts. Apparently this part is discontinued. Trane supplier says...
  4. Replies
    1
    Views
    501

    Best Option for vacuum guage

    I will be purchasing a vacuum guage and was wondering which would be best. I am looking at the Supco VG64 the Fieldpiece SVG2 or the Yellow Jacket 69080. Any recommendations?
  5. Replies
    4
    Views
    918

    Thank you I'll check them both out.

    Thank you I'll check them both out.
  6. Replies
    4
    Views
    918

    Manual J Software

    I am considering purchasing software to do Manual J calculations. Is anybody using software that they would recommend?
  7. Replies
    75
    Views
    9,523

    Yep, absolutely call them back. It should not be...

    Yep, absolutely call them back. It should not be doing that and if it continues could severely damage your comprssor. Most likely a problem within the electrical/start system.
  8. Replies
    21
    Views
    1,933

    Would not do it. It's not designed for that.

    Would not do it. It's not designed for that.
  9. Replies
    5
    Views
    1,226

    In answer to your question yes the system can...

    In answer to your question yes the system can generally be flushed, cleaned and pressure checked as long as there are not larger particles, parts lodged somewhere within the system. It can also have...
  10. I can only guess that the system was sized...

    I can only guess that the system was sized properly and prior to the additions of the garage and screened in porch. Those two locations may very well be poorly insulated and after adding them to the...
  11. Thread: need help

    by binkster
    Replies
    4
    Views
    613

    Generally sizes can be determined through the...

    Generally sizes can be determined through the model number. Somewhere in the middle or at the end two digits represent unit size. With your model number I would interpret it to indicate about a 2.5...
  12. With your description it makes you wonder if he...

    With your description it makes you wonder if he even knows what he is doing. If he is releasing gas into the air I would run away not walk that could become a serious problem. You should look for...
  13. Replies
    11
    Views
    595

    R22 is authorized to be sold until 2020 so it's...

    R22 is authorized to be sold until 2020 so it's going to be around. The EPA intent was to begin equipment phase out of R22 products after 2010 but due to a loop hole, without going into to much info...
  14. Replies
    11
    Views
    595

    Something is causing your compressors to fail, if...

    Something is causing your compressors to fail, if in fact they have. I would get a second opinion, find out why they failed and repair it. It's only two years old it shouldn't require a complete...
  15. Replies
    2
    Views
    568

    The web site says it is not recommended for...

    The web site says it is not recommended for systems under 100 tons. I'd be using it primarily for residential. Thanks for the info.
  16. Replies
    2
    Views
    568

    Fieldpiece SVG2 Vacuum Gauge

    I am looking to purchase a Fieldpiece SVG2 vacuum gauge and am wondering what opinions there are out there about this unit. Would you recommend the Fieldpiece unit or another brand?
  17. Replies
    51
    Views
    2,740

    I would suggest you get a second opinion. At ten...

    I would suggest you get a second opinion. At ten years old you should have some life left in the unit. The compressor might be at the edge of warranty not sure. Looks like you are doing your...
  18. Replies
    14
    Views
    7,953

    It is somewhat labor intensive as the system has...

    It is somewhat labor intensive as the system has to be vacuumed down, brazed connections disconnected and rebrazed and recharged. Not really that big of a deal, I agree with Diceman I would probably...
  19. Replies
    15
    Views
    1,235

    What do you mean "have" a residential evaporator...

    What do you mean "have" a residential evaporator coil? What is your intent with this? Based on the question if you plan on personnaly installing it you better get some help because it doesn't sound...
  20. Replies
    33
    Views
    2,490

    I'm just a little currious, your post says you...

    I'm just a little currious, your post says you are looking to purchase, my question is how do you plan on making a purchase without the proper certifications? Most suppliers I know will not sell to...
  21. Replies
    6
    Views
    657

    Sounds like you have some sort of a problem going...

    Sounds like you have some sort of a problem going on with the system. How insulated and sealed is the attic? I would think you have more than adequate capacity, if anything I would think is is a...
  22. Sticky: I have always been a pretty good do it...

    I have always been a pretty good do it yourselfer. Studied construction is high school and have built homes and garages. My plan as a youth was to get into the trades but I took a different path...
  23. Replies
    29
    Views
    2,861

    I ment to say dry bulb issue.

    I ment to say dry bulb issue.
  24. Replies
    29
    Views
    2,861

    Thanks, I am anxious to receive and use mine. ...

    Thanks, I am anxious to receive and use mine. I'll watch for an answer on your possible wet bulb issue.
  25. Replies
    5
    Views
    1,281

    3 ton unit for 2400 square feet in CT. Yes that...

    3 ton unit for 2400 square feet in CT. Yes that would be plenty big enough my guess is that it is too big. I agree a manual J calculation for proper size should be done to determine if you do in...