  1. Replies
    2
    Views
    75

    My main brand (which is York) offers a 10 year...

    My main brand (which is York) offers a 10 year labor warranty that works in tandem with the manufacturers parts warranty. The fine print does say regular maintenance is required to maintain the...
  2. Replies
    9
    Views
    139

    In my area it is 3 feet from a door or...

    In my area it is 3 feet from a door or operational window. Is there any reason it can't be farther from the door? The inspector will make them change it if it violates local code.
  3. Replies
    25
    Views
    725

    Are you saying the condenser and air handler are...

    Are you saying the condenser and air handler are running off the same breaker? If so, this is wrong and needs to be corrected
  4. Replies
    3
    Views
    251

    You or someone needs to get up in the attic and...

    You or someone needs to get up in the attic and see what's going on. There should be a secondary drain pan that could be full of water. Good luck
  5. My opinion on why they don't offer in half ton...

    My opinion on why they don't offer in half ton sizes is the manufacturing and engineering payback for them isn't there. They can only sell them in certain areas of the country. I'm in northern ohio...
  6. Replies
    3
    Views
    617

    Thanks for the response. I've told him we need to...

    Thanks for the response. I've told him we need to replace the entire unit with an appropriate set of logs and controls.
  7. Replies
    3
    Views
    617

    Outdoor fireplace

    thanks for reading this. I have a customer (bar owner) who has an outdoor fireplace and was given a set of gas logs and a burner. Problem is that the gas valve and controls don't work. As most bar...
  8. Thread: Funny noise

    by NCHeat
    Replies
    2
    Views
    194

    Does not seem like a normal noise to me

    Does not seem like a normal noise to me
  9. Replies
    10
    Views
    691

    If I could just get one of these jobs I'd be set....

    If I could just get one of these jobs I'd be set. Lol
  10. Thread: New Install

    by NCHeat
    Replies
    5
    Views
    464

    I'd go with the 2 unit set-up. Two units gives...

    I'd go with the 2 unit set-up. Two units gives you better temp control than 1 unit with a zoning system.
  11. I doubt you have the manometer needed to...

    I doubt you have the manometer needed to determine static pressure but maybe you do. Any HVAC tech worth a damn will have the ability to measure this.

    I it is not strange to put a 4 ton AH on a...
  12. Replies
    12
    Views
    492

    My guess is the compressor is bad. If it won't...

    My guess is the compressor is bad. If it won't pull down to 0psi replace the compressor or the system.
  13. The only way I see this working well is if both...

    The only way I see this working well is if both AH come on at the same time every time. This would delete the purpose of have in 2 units. Get 2 separate systems.
  14. Thread: Flashing Lights

    by NCHeat
    Replies
    5
    Views
    412

    Is there a problem or is the light just on? That...

    Is there a problem or is the light just on? That info should be in the install and operation manual
  15. Climate Trak

    Climate Trak
  16. Replies
    9
    Views
    644

    Poll: York and evcon are the same thing. Lennox and air...

    York and evcon are the same thing. Lennox and air flow are the same. Bryant is a carrier. Which contractor is the best of your bunch? That's where the difference is.
  17. Replies
    5
    Views
    588

    Is it a 2 stage furnace or a 2 stage heat pump? I...

    Is it a 2 stage furnace or a 2 stage heat pump? I would suspect its a 2 stage heat pump. Both systems could have a variable speed blower "ECM" I'm not sure i see the need for a mod in a DF system
  18. It's hard to tell from here exactly what is...

    It's hard to tell from here exactly what is causing failure. I have honeywell zone systems on many VS systems and have no issues. What zone panel are you using? First thing you need to do is decide...
  19. Thread: 2 units or 1

    by NCHeat
    Replies
    7
    Views
    363

    If you want it zoned then 2 units may be an...

    If you want it zoned then 2 units may be an option. Otherwise 1 should do it. Where do you live that you need 4 tons for 2600 sq ft?
  20. Replies
    14
    Views
    701

    Who installed the system? If you have hot and...

    Who installed the system? If you have hot and cold spots call them back to fix it. (I know the answer to this question)
  21. Replies
    39
    Views
    1,208

    I have not had any repeating problems with York...

    I have not had any repeating problems with York since the "Blue" coils went away. All equipment is the same. Everyone has the same junk in different colored boxes.
  22. I wouldn't touch that with a 100,000 foot pole....

    I wouldn't touch that with a 100,000 foot pole. Its all fun and games until the house catches fire and people die. get the right furnace for the application or DON'T do it.
  23. Replies
    1
    Views
    232

    Ceiling mounted mini splits

    Does anyone know of a ceiling cassette that will fit between 16oc joists? Everything I see is a little wider than that.
  24. Thread: PSC vs. ECM

    by NCHeat
    Replies
    18
    Views
    1,047

    If your customer wants to improve cost of op,...

    If your customer wants to improve cost of op, comfort and sound why not recommend replacing the entire unit to something high efficient with a true ECM.
  25. Replies
    42
    Views
    1,718

    How do you plan on storing it?

    How do you plan on storing it?