Search:

Type: Posts; User: bertoh

Page 1 of 9 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    28
    Views
    2,894

    I was there 20 something years ago, I moved on,...

    I was there 20 something years ago, I moved on, but I remember a little turmoil with a manager back then too. Jim, not sure if you are the highland variety of Jim that was there in early 90's. If you...
  2. Thread: York ICE

    by bertoh
    Replies
    10
    Views
    865

    I am now.

    I am now.
  3. Thread: York ICE

    by bertoh
    Replies
    10
    Views
    865

    setup.exe file

    York 56, would you have the autorun file/setup.exe for IcE1.04. I have the software backed up to cd from an old laptop that crashed. But the trainer carefully removed the setup file so this could not...
  4. Replies
    14
    Views
    2,210

    I'm having a problem in chiller open forum. No...

    I'm having a problem in chiller open forum. No matter how many times I log in, my user name is not in top right corner. But I can come out to Pro forum and be logged in. So I think there is a problem...
  5. Replies
    14
    Views
    2,210

    I'm having same issue trying to click on a file...

    I'm having same issue trying to click on a file in a thread and it keeps telling me log in, I do , and a1 second box welcoming me pops up but cant get in. also my user name not coming up in top right...
  6. Replies
    9
    Views
    2,691

    You've got mail

    You've got mail
  7. Replies
    4
    Views
    691

    Hi Forum We are facing reconciling a badly...

    Hi Forum
    We are facing reconciling a badly constructed billing agreement with our on site co generation providers and trying to formulate an agreement for the future. I take it you feel you are...
  8. Replies
    9
    Views
    2,691

    Email

    Update your CP Aust, with email address. I might find something for you.
  9. Replies
    5
    Views
    17,552

    Multiply tonnes by 12 to get BTU's in Thousands....

    Multiply tonnes by 12 to get BTU's in Thousands. Divide the answer by 3.415 to get watts by the thousand or KW. Their is 3.415 BTU in a Watt
  10. Replies
    9
    Views
    13,187

    500 is a constant for water. The reason I believe...

    500 is a constant for water. The reason I believe is, you are dealing in GPM(minutes) and BTU/HR (hours)
    60 Min. in an hour and the weight of 1 US gallon of water 8.31 lbs.
    60 x 8.31 = 498.6...
  11. that formula is for chiller COP. If you are doing...

    that formula is for chiller COP. If you are doing total plant COP, then you need alll pumps and tower fans. Tower fans are cycling so you would need a KWmeter to measure that. BUT CHILLER cop will...
  12. KW refrigeration div by KW electric input to...

    KW refrigeration div by KW electric input to motor.
    You need a Kw meter really. Electric KW= KVA x Pf (power factor)
  13. Replies
    11
    Views
    1,122

    My mistake, try it again.

    My mistake, try it again.
  14. Replies
    11
    Views
    1,122

    You got mail

    You got mail
  15. Replies
    11
    Views
    1,122

    R404, not saying i am an expert on the YT, but...

    R404, not saying i am an expert on the YT, but it sounds very similar control to the YK. I would double check your refer level sensor calibration, you may be stacking it higher than you think. If...
  16. Thread: 19XR

    by bertoh
    Replies
    13
    Views
    1,027

    thanks, CHMAN, would appreciate anything on this...

    thanks, CHMAN, would appreciate anything on this machine. have the pic 2 IOM. Never thought about the heater. alot of other issues, running HP because of low flow, tower fan gone bad, designed around...
  17. Thread: 19XR

    by bertoh
    Replies
    13
    Views
    1,027

    Ph-D I could use one too. Also looking for a...

    Ph-D I could use one too. Also looking for a renewal parts form on these. I have a 19xr frame 3 with pic2, low Dis. SH at times, i am thinking the linear float is sticking. Waitng for price and...
  18. Replies
    9
    Views
    13,187

    The formula for KW of refrigeration is L/s x...

    The formula for KW of refrigeration is L/s x Delta T(*C) x 4.19kj/kg (for Water)
    To convert GPM to L/s GPM (div by) 60= GPS
    GPS x 3.785= L/s
    60 seconds in a...
  19. Thread: YK style G

    by bertoh
    Replies
    8
    Views
    892

    Thanks for that york56, some how the email...

    Thanks for that york56, some how the email notification for response to this thread went to spam folder.
  20. Thread: YK style G

    by bertoh
    Replies
    8
    Views
    892

    No micro-gateway or e-link. If you check the...

    No micro-gateway or e-link. If you check the sales order the number of tubes does not match the renewal parts number of tubes on the style E &F, and i would say the same for G. Trying to calc min...
  21. Thread: YK style G

    by bertoh
    Replies
    8
    Views
    892

    YK style G

    I am looking for info on style G. I see the main board has changed from style E. I have a start up on one in a few weeks so I need the IOM on the controls. Also looking for the Renewal Parts on it to...
  22. Replies
    6
    Views
    932

    the ME says that because he got that job messed...

    the ME says that because he got that job messed up. I dont think you can get a cent. down to 20% FLA. If you google "Low Delta T syndrome" you will get a boat load of info on Pri/Sec problems. To me...
  23. Thread: Watt for Watt

    by bertoh
    Replies
    18
    Views
    1,760

    If your customer is paying 1.5M per year on...

    If your customer is paying 1.5M per year on electric, it would be well worth thier while to install a Tri Gen system. Chances are they all ready have a backup generator. Tri Gen takes the waste heat...
  24. Replies
    89
    Views
    8,410

    You quoted the work for 16 hrs. and never looked...

    You quoted the work for 16 hrs. and never looked back thru the customers quote history to find out the last one was 10 hrs!! A little incompetent apprentice manager.
    Is it the same comp that is...
  25. Thread: Plain English

    by bertoh
    Replies
    2
    Views
    664

    Is it the AC 256. It has been about 10 years...

    Is it the AC 256. It has been about 10 years since I dealt with them, but they are great. It can get a bit involved with how you write calculations but it works well when you get the feel for it. I...
Results 1 to 25 of 224
Page 1 of 9 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine