Search:

Type: Posts; User: AllTemp

Page 1 of 17 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    3
    Views
    357

    Yelp.com Rip Off

    Yes I've been filing away and intend on kicking up as much dust as possible. The so called unavailable account representative responded to my letter like this:

    Mel,

    I am sorry that I didn't...
  2. Replies
    3
    Views
    357

    Yelp Advertising

    Posted several weeks ago about Yelp.com for comments. Well my tradesman if you've got $$$$ to burn and throw away Yelp will definately assist you.

    Took out an advertising campaign for $1500...
  3. Replies
    20
    Views
    1,571

    What I am suggesting is Yelp controls the ads...

    What I am suggesting is Yelp controls the ads served up whsat reviews get posted which don't . I spend 2/3 my budget first week and never recieved a call from a Yelp consumer ) over 110+0 clciks......
  4. Replies
    20
    Views
    1,571

    You don't even have to be a client all it takes...

    You don't even have to be a client all it takes is a Yelp reviewer claim your company and post negative or positive.
  5. Replies
    20
    Views
    1,571

    YELP.COM Ripp Off!

    Yeah, Mike with the recent hype of social media I was one of the unfortunate ones who kept telling Yelp advertisers "No" and caved into the constant pushey rep pointing out what the negative reveiws...
  6. Replies
    20
    Views
    1,571

    Wow so difficult to ask for people's experience...

    Wow so difficult to ask for people's experience with Yelp! Really...

    Any way to delete this thread and go back into hiding.
  7. Replies
    20
    Views
    1,571

    Nice to see replies... But what about Yelp.com...

    Nice to see replies... But what about Yelp.com anyone here have any experience with them.

    Seems like to get you hooked they don't stay off your phone. But seal the deal sign up and it's where did...
  8. Replies
    20
    Views
    1,571

    Yelp.com a Waste of Advertising Dollars!

    Yelp.com Good or Bad?
    I recently had taken out self help ad compains with Yelp.com but immediately noticed each and every morning immediately my budget was getting used up by (Ghost) clicks and my...
  9. It had been so long ago I thought I'd seen a...

    It had been so long ago I thought I'd seen a picture of Joe. Here it is and his buddy was Druid. I made that post on another forum.

    Good times and memories live for ever!
  10. RIP Joe Sykes " Pegleg"

    I met Joe on a job site ,he brought along a electrician friend can't remember his name they helped me figure out some wiring on an old Climatrol VAV , we changed out the old mechanical step...
  11. Replies
    35
    Views
    4,432

    I own so many micron gauges bought over the...

    I own so many micron gauges bought over the years. From the old Robinaire,Thermal Cool,Tiff,Supco ,JB,CPS....Many... But I have to tell you I love the Fieldpiece SMAN460... What can't that manifold...
  12. Funny to come across this old thread. Just came...

    Funny to come across this old thread. Just came across a 2 ton Rheen... Outdoor expansion been problematic forever😵
  13. Replies
    52
    Views
    2,385

    Be interesting to power the furnace up on an...

    Be interesting to power the furnace up on an alternative circuit from the busses. Definitely going to be a loose connection some where.... Wish I was there I love calls like this.

    On one today ,...
  14. Replies
    52
    Views
    2,385

    When you unplugged the ignitor on a call for heat...

    When you unplugged the ignitor on a call for heat the board didn't provide 110-120 volts momentarily before giving you a flash error code?

    I dam sure wouldn't have left there without knowing...
  15. Replies
    52
    Views
    2,385

    How is it you couldn't just use your meter test...

    How is it you couldn't just use your meter test leads down into the top of the Molex connector or some test leads...

    Man you need to outfit yourself with some basic gear... Seriously going back......
  16. Replies
    52
    Views
    2,385

    Board and ignitor have been replaced. This...

    Board and ignitor have been replaced. This problem with the ignitor not teaching temp is the original complaint reoccurring with a new board and ignitor ?
    if that's the case be checking the ignitors...
  17. Replies
    52
    Views
    2,385

    I'd want to know what the voltage is at the...

    I'd want to know what the voltage is at the ignitor when it's failing?
  18. Replies
    7
    Views
    923

    Been using 3/4" wall UV Resistant but this...

    Been using 3/4" wall UV Resistant but this inspector want me to wrap it with foul tape.
  19. Replies
    7
    Views
    923

    Lineset UV Protection

    What are your inspectors requiring for UV protection on your Insul-tube ?
  20. Thread: TXV Question

    by AllTemp
    Replies
    11
    Views
    1,144

    Starters verify txv Operation. Disconnect the...

    Starters verify txv Operation. Disconnect the bulb warm it up watch your pressures. If your suction climbs I would look for debri in the inlet screen.
  21. My opinion would be contactor after your...

    My opinion would be contactor after your statement pushing in the plunger. Cost of contactor change it!
  22. Replies
    62
    Views
    4,537

    I remember getting booted of alt.hvac news feed...

    I remember getting booted of alt.hvac news feed promoting the site,lol!
  23. Replies
    62
    Views
    4,537

    One foot in the grave , their definately throwing...

    One foot in the grave , their definately throwing dirt on sometimes... A little crusty but still here
  24. Replies
    39
    Views
    2,518

    Mini Split Set Point Issues

    Hey Ya'all!!!! Homeowner of this thread has contacted me for some assistance.

    Its my understanding there may be a resistor on the board that maybe giving a wide dead band ???

    I understand this...
  25. Replies
    37
    Views
    3,007

    My thought on this mess as i understand it is...

    My thought on this mess as i understand it is there doesn't seem to be any regulation on the bypass dampers. Do you know if their Barometrically adjusted or Electronically dampers. I prefer...
  26. Replies
    0
    Views
    907

    Coleman Polar Prince

    Anyone familiar with certainty what this old dinosaur would be?

    Coleman Polar Prince

    Model #6942A801

    S/N #3691678

    Called Coleman forwarded to their Mobil Home division they can't find any...
  27. Replies
    31
    Views
    1,908

    Overboard?

    This is hardly overboard... The thread started from some twit that didn't have a clue about anything saying he was sick and tired...

    Get a grip in my wifes district alone the poltics between the...
  28. Replies
    31
    Views
    1,908

    Recap

    Sounds like things are a little different in NJ... here we share cost of medical...for the last 3 years my wife along with hundreds of other teachers hot fired because the budget... my wife was...
  29. Replies
    31
    Views
    1,908

    Clueless

    Much like any profession the example of the two childhood friends who are teacher are exactly the type of teachers that set the stage for the type of banter going on here.

    Listen I stand up for...
  30. Replies
    31
    Views
    1,908

    Federal Mandated Curriculm

    You really haven't figured anything out... your clueless! The unions don't control your district, the teachers.... Not the High Paid Administrators ...Nurses,Counslers,Principals, Ect...

    If it...
  31. Replies
    31
    Views
    1,908

    yada yada

    You couldn't get me to baby sit 30-40 + kids everyday for 50-60K a year...
    It's about time these complaining bastards realize they need to be responsible for thier
    sons and daughters... start the...
  32. Thread: Rheem manuals

    by AllTemp
    Replies
    6
    Views
    5,369

    Thanks ...

    Not sure which address that would be John, appreciate the help.... Current is
  33. Thread: Rheem manuals

    by AllTemp
    Replies
    6
    Views
    5,369

    Rheemote.net

    Cannot log into Rheemote.net , link keeps saying need user id/passowrd... So I click log in problems it emails me my password but not login...

    Need specification for a REAB1415J, if someone could...
  34. Thanks Marvin, I appreciate the information, Mel

    Thanks Marvin, I appreciate the information, Mel
  35. Holly/ Fraser Johnson AGP6-60-100-1 serial #1000853

    One of our tech condemned this old girl and drew out the duct lay out and assumed it had reverse RA/SA ...

    Homeower has stated she has 3 qoutes from other companies that claim this unit does not...
  36. Replies
    35
    Views
    9,306

    WITH THE NEW REGULATIONS SOON COMING These...

    WITH THE NEW REGULATIONS SOON COMING

    These caps are the TRICK!
    http://www.noventcaps.com/

    http://www.noventcaps.com/images/workParts.jpg
  37. Pegleg RIP My Friend!

    I am deeply saddened by this news, I didn't know Joe as well as most. I met Joe a few times around the nieghborhood, he was an excellent refrigeration mechanic and knew his way around!




    ...
  38. Replies
    6
    Views
    889

    Using Gas as Aux heat witha heat Pump

    Whats any ones thoughts on using a gas fired furnace as Aux Heat with a Heat Pump? Do not have the ac power to run Aux electric heat strip.. located East Texas. Could one put a short time delay on...
  39. Replies
    27
    Views
    16,437

    Artic ...

    Last time I check it is spelled Arctic, I know of Arctic Mechanical, Inc. in Corona been in buisness for 40 years...

    http://www.arcticmechanical.com
  40. Replies
    31
    Views
    2,421

    Hacker Alert

    Beware Salt Lake Utah, You have a new Craftsman in Town. And he has his own cuttin torch..... he is gona show them how to Braze and Charge his unit to match his cold beer........... East Texas will...
  41. Replies
    31
    Views
    2,421

    No Worries

    No Worries Dangling Wrangler ...

    This individual is 1500 miles away but he frequents this forum often for solutions to his hacker and know he'll enjoy the eye opener if he pays close attention...
  42. Replies
    31
    Views
    2,421

    Proffesional Vs. Hack

    What would you call a guy who uses a compound gauge that is stuck on 250 that also claims you don't need to know all that sub cooling /superheat crap. A good seasoned service tech can charge a...
  43. Thread: Long Line sets

    by AllTemp
    Replies
    6
    Views
    1,225

    huh?

    Have been a member of this forum for a great many number of years, as a matter of fact since it started. I'm still amazed at the intelligence that is displayed:confused:
  44. Thread: Long Line sets

    by AllTemp
    Replies
    6
    Views
    1,225

    Long line sets

    Texas Tec
    This is Pete Mels brother. all the temps have been taken in line with goodman specs. this unit replaced a exsisting unit that was not 13 seer, we do have a temp problem in the attic...
  45. Thread: Long Line sets

    by AllTemp
    Replies
    6
    Views
    1,225

    Sub Cooler

    As Pete menitioned in his original post it is utilizing a TXV, the benifit of strapping the 3/8 liquid line next to the return (suction) for a few feet it would be a subcooler ( primitive) but I...
  46. Thread: Long Line sets

    by AllTemp
    Replies
    6
    Views
    1,225

    Long Line sets

    Hello Group,:)
    Name here is Pete This is My brothers user name I am a rookie at this, He is unavailable............. Have a question. Have a 2 1/2 Goodman 13 seer with a matched indoor unit straight...
  47. Replies
    25
    Views
    2,730

    EAC Cell Replacement

    We had two Trion EAC's in our home and finally heeded to some of the warnings of their Ozone output an elected to use Honeywell F50 models in them.. For me the 20x25x4 fit perfectly.

    With...
  48. Replies
    16
    Views
    2,081

    Laundry Residue's!

    I have seen heavy use of fabric softeners in the laundry room near the FAU along with detergents and the like have lead to premature faulure. Dryer lint especially can be a culprit.

    It doesn't...
  49. Replies
    10
    Views
    1,277

    Banned - Geeeez I'm have Charter Memebrship

    :D

    I'm lurking ...

    I was the 28th member to sign on...
  50. Replies
    115
    Views
    15,332

    North State Tools

    http://www.northstate.com/ridgid/media/rgstart0803.jpgI had already ordered my 1st SeeSnake before I ever read this thread from North State Tools . Prompt delivery for the SeeSnake but the extension...
Results 1 to 50 of 845
Page 1 of 17 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Comfortech365 Virtual Event