06-18-2012, 02:35 PM
- Replies
- 6
- Views
- 411
Thanks, beginning to think that as well.
Thanks, beginning to think that as well.
-
06-18-2012, 02:34 PM
- Replies
- 6
- Views
- 411
Head pressure stays at 150, suction drops. Will...
Head pressure stays at 150, suction drops. Will not run long enough for superheat or subcooling. House is 4 years old, did find out the outdoor unit was stolen before they bought it ( left lines...
-
06-17-2012, 12:55 PM
- Replies
- 6
- Views
- 411
american standard cycling on low pressure
I have a unit that is messing with my head. American standard cutting off with low suction pressure, whether the reversing valve is energized or not. Hard to diagnose because it will not run. As soon...
-
10-17-2009, 05:33 PM
Thread: heatmaster log problem
by jeremydp- Replies
- 2
- Views
- 853
heatmaster log problem
I am working on a set of logs that i can get the pilot to light but when i try to turn on to burners it cuts completly down. Shuts pilot off, i can hear the valve. It has a thermocouple and...
-
01-16-2009, 10:09 PM
Thread: bad compressor
by jeremydp- Replies
- 7
- Views
- 378
I am not second guessing, i know how to hook up...
I am not second guessing, i know how to hook up compressor plus can read a wiring diagram. I am simply asking a question.
-
01-16-2009, 10:07 PM
Thread: bad compressor
by jeremydp- Replies
- 7
- Views
- 378
The compressor side of split capacitor. I ran to...
The compressor side of split capacitor. I ran to start, he insisted to hook up at run. I am not trying to be confusing. The common is correct at compressor but basically start and run backwards.
-
01-16-2009, 09:50 PM
Thread: bad compressor
by jeremydp- Replies
- 7
- Views
- 378
bad compressor
I helped someone change out a compressor today. I brazed out old comp. and set new one, pressure tested and started to pull vacuum. I wired correctly but he insisted that the herm wire off the cap....
-
12-30-2008, 10:44 PM
Thread: furnace confusion bummer
by jeremydp- Replies
- 4
- Views
- 345
Sounds like it may be cycling on limit switch and...
Sounds like it may be cycling on limit switch and not stat. Get the professional back out. Explain it is never reaching set temperature. It may operate different but it should reach 70 degrees.
-
12-20-2008, 01:22 PM
Thread: Gas piping (hard pipe)
by jeremydp- Replies
- 27
- Views
- 3,064
I agree maybe a little too much dope, and yes...
I agree maybe a little too much dope, and yes shoulda recut for a solid piece. But all in all i think it looks good. Lord knows the crap i have seen.
-
12-20-2008, 09:33 AM
Thread: Gas piping (hard pipe)
by jeremydp- Replies
- 27
- Views
- 3,064
Floor valves arent required in my county, just a...
Floor valves arent required in my county, just a shut off, there is one easily accessible in the box itself. Yeah i d rather have too much pipe dope than not enough.
-
12-20-2008, 09:21 AM
Thread: Gas piping (hard pipe)
by jeremydp- Replies
- 27
- Views
- 3,064
Gas piping (hard pipe)
10390
10392
10393
10394
10395 -
10-21-2008, 08:20 AM
Thread: condenser motor
by jeremydp- Replies
- 2
- Views
- 301
condenser motor
I changed a condenser motor on a 3 1/2 ton 12 seer tempstar about 6 months ago. About 2 months ago got a call. The motor was making a horrible racket. It acted like the bearing was bad so i replaced...
-
07-13-2008, 07:40 AM
- Replies
- 18
- Views
- 1,130
it sounds like they havent really found the...
it sounds like they havent really found the problem. Did they do a nitrogen check when they changed coil? Maybe still a leak.
-
07-13-2008, 07:37 AM
Thread: Clueless and need help!
by jeremydp- Replies
- 21
- Views
- 941
You can take the front off the stat and see if...
You can take the front off the stat and see if there is a y2. if not it isnt going into second stage.
-
07-12-2008, 07:52 PM
Thread: selecting a heat pump etc.
by jeremydp- Replies
- 8
- Views
- 545
Dual fuel may not be a bad idea. may offset price...
Dual fuel may not be a bad idea. may offset price of wire and new breaker.
-
07-04-2008, 09:03 AM
- Replies
- 15
- Views
- 1,253
Are you sure it isnt screwed on the inside? Seems...
Are you sure it isnt screwed on the inside? Seems like the filter, plenum, ductwork sure would be heavy for tape and mastic to hold up. On the door make sure the filter rack is square. The doors are...
-
07-03-2008, 11:25 PM
Thread: Trane XL14c - two-stage cooling?
by jeremydp- Replies
- 7
- Views
- 1,761
it is not two stage cooling, only 16i and 19i....
it is not two stage cooling, only 16i and 19i. You may still use variable speed though.
-
06-27-2008, 07:08 PM
Thread: HVAC guy came out, recommends Goodman
by jeremydp- Replies
- 291
- Views
- 10,933
had to pull blower motor,not tightened on shaft....
had to pull blower motor,not tightened on shaft. v/s pigtail not plugged in. wires not in harness on 16i. reversing valves banging. look at a weathertron from last year and now tops are much more...
-
06-27-2008, 06:53 PM
Thread: HVAC guy came out, recommends Goodman
by jeremydp- Replies
- 291
- Views
- 10,933
i have been having more problems out of them...
i have been having more problems out of them lately. simple things, but i shouldnt have to troubleshoot new eqp.
-
06-27-2008, 06:12 PM
Thread: HVAC guy came out, recommends Goodman
by jeremydp- Replies
- 291
- Views
- 10,933
Tessmer, just to satisfy my own self, what brands...
Tessmer, just to satisfy my own self, what brands to you install or suggest?
-
06-27-2008, 06:11 AM
Thread: HVAC guy came out, recommends Goodman
by jeremydp- Replies
- 291
- Views
- 10,933
In my opinion goodman is a good product and it...
In my opinion goodman is a good product and it has a 10 yr. warranty. I also like the lennox units, they are nice products. Trane well i have been having a little problem (minor yet problems) with...
-
06-23-2008, 09:48 PM
Thread: installation
by jeremydp- Replies
- 4
- Views
- 316
I use line hide. Good sleak look.
I use line hide. Good sleak look.
-
06-18-2008, 05:33 PM
Thread: boards oppinions.
by jeremydp- Replies
- 12
- Views
- 512
Is it unethical or is it good,sound advice?
Is it unethical or is it good,sound advice?
-
06-17-2008, 06:00 PM
Thread: boards oppinions.
by jeremydp- Replies
- 12
- Views
- 512
I did not think is was worth fixing on a 20 yr....
I did not think is was worth fixing on a 20 yr. old system, though might run into further problems. But i am basically still a newbie and thats why i asked. Thanx for the input, i will hunt that leak...
-
06-17-2008, 06:19 AM
Thread: boards oppinions.
by jeremydp- Replies
- 12
- Views
- 512
boards oppinions.
I recently had a no cooling call. Found very low on charge and just been charged up last week. I then explained the options of just changing system out. It is a 20 yr. old tempstar. She said that the...