Search:

Type: Posts; User: wta12

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Replies
    1
    Views
    208

    inertia base for inline pump

    Hello,
    I checked ashare handbook and got recommend that don't need inertia base for inline pump. However, they required isolator type 3 (spring). I would like to get advice for my case due we have...
  2. Replies
    0
    Views
    1,302

    Honeywell EBI R410 modules

    Hello all,
    I got propose for EBI software R410 R1 but have a lot confusing with EBI software module features. Please anyone who know give me some explanation about their module - Followed items i...
  3. Replies
    9
    Views
    3,122

    Could you send me the .pdf file of IOM ? Regards

    Could you send me the .pdf file of IOM ?
    Regards
  4. Replies
    4
    Views
    912

    Thank for advice, ,we use chilled water coil and...

    Thank for advice, ,we use chilled water coil and electrical heater
    But i cant find any specified document for AHU with close control, please have some source for me
    Regards
  5. Replies
    4
    Views
    912

    AHU with close control

    i need find some document/articles, which have deeply information about close control for AHU. My project need all-air AHU with recirculation, dehumidify cooling, humidify, electrical heating for...
  6. Replies
    11
    Views
    2,284

    Thank for a detail comment. as i want to know...

    Thank for a detail comment. as i want to know about water valve for fancoil unit only (fan coil parallel with DOAS) cause problem with big number (as you said) - so its better to have spring...
  7. Replies
    11
    Views
    2,284

    floating or moudlating control valve

    PLs help me. I want to know which control method is better for water side FCU capacity control in DOAS (100% fresh air AHU) - FCU arrangement ? FCU is base on thermostat - for realizing the...
  8. Replies
    9
    Views
    2,283

    thanks for comment

    you nailed my concern. but I think it very rare if freezing cooling coil when supply chilled water temperature remain constant (7 oC) and have air flow even with very low designed percent (10%...
  9. Replies
    9
    Views
    2,283

    Sorry for not fully understand your statements....

    Sorry for not fully understand your statements. As per your comments, i thinks the coil will be freeze only in winter. But i live on tropical country, which have winter > 9 oC and i cant see any...
  10. Replies
    9
    Views
    2,283

    Thanks for advices. After review the definitions,...

    Thanks for advices. After review the definitions, i think, i need advice about the minimum coil face velocity on AHU. Somewhere i saw for coolng comfort selected range about 1,5 - 3,0 m/s and i would...
  11. Replies
    9
    Views
    2,283

    thank for recommendations, i'm very grateful if...

    thank for recommendations, i'm very grateful if could know source of them (standard, guidelines, design manual...)
    however i want knows limit cause the equipment and system characteristic, for...
  12. Replies
    9
    Views
    2,283

    [Question] VAV minimum airflow

    Hi
    in some references, i read that, the minimum air flow for VAV system is 30% of designed (max) airflow. It's can be used for all or depend case by case ?
    Thanks
Results 1 to 12 of 59
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event