  1. Replies
    6
    Views
    580

    That is a Trane uc210 Sent from my iPhone...

    That is a Trane uc210


    Sent from my iPhone using Tapatalk
  2. Is the set point dial enabled? Also is CTL STPT...

    Is the set point dial enabled? Also is CTL STPT overridden? I only assume with the info you have that the set point dial is disabled. And you CTL STPT equals your DAY HTG STPT.
  3. Replies
    6
    Views
    423

    There is an FLN driver, but will only communicate...

    There is an FLN driver, but will only communicate to generic tecs. Custom applications and any extended io such as dpu, mpu and bims will not be discovered. Does the current insight server have the...
  4. Replies
    1
    Views
    277

    The SystControl is what you want, you'll be able...

    The SystControl is what you want, you'll be able to see all your indoor units as well as the outdoor unit.


    Sent from my iPhone using Tapatalk
  5. Replies
    9
    Views
    932

    The driver is very limited. Sent from my...

    The driver is very limited.


    Sent from my iPhone using Tapatalk
  6. Replies
    9
    Views
    932

    You will not ba able to see many devices when...

    You will not ba able to see many devices when using a p1 driver. Expansion modules such as pxms and bims, UCs DPMs and certain TEC applications.


    Sent from my iPhone using Tapatalk
  7. Replies
    6
    Views
    372

    I got water drops in my otterbox and phone...

    I got water drops in my otterbox and phone started going crazy. Giving a 1.5 year old a bath will do that.

    Sent from my SM-G900V using Tapatalk
  8. Replies
    6
    Views
    372

    Sent from my SM-G900V using Tapatalk

    Sent from my SM-G900V using Tapatalk
  9. Replies
    6
    Views
    372

    V'''v:v:v:v:vv::v:::v:'vv''vçccccccccccccccccccccc...

    V'''v:v:v:v:vv::v:::v:'vv''vçcccccccccccccccccccccvvvv:::::vvv::::::::::::::vvvvvv vvv

    Sent from my SM-G900V using Tapatalk
  10. You only need to hook up to one panel on a single...

    You only need to hook up to one panel on a single P2 network. Huge downside to that is the more points you have in point monitor the slower this solution will be. Your expectation shouldn't be to...
  11. No, you can not hook up the trunk interface to...

    No, you can not hook up the trunk interface to the jace, your only options are to use the csi driver thu the mmi port or if the insight server has a bacnet license, you can export the points via...
  12. Just found out on a lochenvar integration I'm...

    Just found out on a lochenvar integration I'm currently doing, lochenvar is now installing bacnet cards in the boiler and will no longer need the protonode. I'll be disovering these Friday to...
  13. Replies
    2
    Views
    453

    Are you designing this system yourself? Is...

    Are you designing this system yourself? Is Siemens your only option? Where are you located?

    Sent from my SM-G900V using Tapatalk
  14. The instance number applies to mstp as well. ...

    The instance number applies to mstp as well.

    Sent from my SM-G900V using Tapatalk
  15. Lochenvar has a field server that is pre...

    Lochenvar has a field server that is pre configured modbus to BACnet, used them several times with ease.

    Sent from my SM-G900V using Tapatalk
  16. Replies
    2
    Views
    447

    Wcis is the program you will need to connect to a...

    Wcis is the program you will need to connect to a tec. The max line driver only supports standard applications, it will not discover an dpu. Mpu or uc controller or special tec applications such as...
  17. There is a background object that is not defined....

    There is a background object that is not defined. They can drive you crazy, especially if there is a lot of lot of associations. Good luck.
  18. Replies
    5
    Views
    757

    It probably needs to be replaced. Are you writing...

    It probably needs to be replaced. Are you writing to any of the subpoints excessively?
  19. Replies
    9
    Views
    1,792

    Firmware upgrade can only be for through com...

    Firmware upgrade can only be for through com tools which is a not distrusted. Calling your local branch is your only option to upgrade.
  20. Replies
    11
    Views
    1,697

    Try network 9

    Try network 9
  21. Replies
    11
    Views
    1,697

    Have you discovered the devices thru the Web...

    Have you discovered the devices thru the Web browser, and verified all your devices were pulled in. There you should see your instance numbers.
  22. Replies
    6
    Views
    730

    Do datamate or wcis have a terminal emulator? I...

    Do datamate or wcis have a terminal emulator? I think they may, I'm used to using hyperterminal, dont remember what the keystrokes are to enable ethernet, you'll also need administration...
  23. Replies
    6
    Views
    730

    The 2.8 panels are made ether net thru...

    The 2.8 panels are made ether net thru hyperterminal. The earlier controllers will need to be flashed by Siemens
  24. Replies
    3
    Views
    646

    Validation of sensors for pharma

    I'm doing a pharmaceutical job where, I am using Vaisala current temp and humidity sensors. The customer has a third party validation company that wants to split and repeat my current signal to use...
  25. Not for anything newer than apogee 2.6

    Not for anything newer than apogee 2.6
  26. They don't, that's how Siemen's keeps their foot...

    They don't, that's how Siemen's keeps their foot in your door. And depending on which product we are talking about, they may make your only option a "fast forward" upgrade.
  27. Yes, that is correct. For power mbc's, mec's. ...

    Yes, that is correct. For power mbc's, mec's. Pxc line the Siemens tech uses firmware loading tool which is part of com tools and is only licensed to Siemens techs.
  28. Replies
    18
    Views
    4,827

    Unresolved, a point is probably failed

    Unresolved, a point is probably failed
  29. Please attach a screens shot of you system...

    Please attach a screens shot of you system profile, the apogee archatecture limits you to one mass storage device (server) you may have many machines with attached BLNS's but only one server.
  30. Replies
    1
    Views
    581

    Database transfer backs up the field panel...

    Database transfer backs up the field panel database "P2" files. The insight backup utility backs up the database of the insight server including reports, trends andgr add graphics.
  31. Replies
    3
    Views
    740

    You need to set the panel using hyper terminal...

    You need to set the panel using hyper terminal and an mmi cable plugged into the mmi port


    Sent from my iPhone using Tapatalk
  32. Replies
    8
    Views
    2,162

    VFDs use BACnet client to import third-party...

    VFDs use BACnet client to import third-party points. BACnet server is used to export Siemens points.


    Sent from my iPhone using Tapatalk
  33. Replies
    1
    Views
    518

    No you can use a comparable wire. Sent from...

    No you can use a comparable wire.


    Sent from my iPhone using Tapatalk
  34. Replies
    8
    Views
    2,162

    Have them purchase the bacnet server through the...

    Have them purchase the bacnet server through the service agreement, price is significantly less, they will probably attempt to upgrade the machine as well as insight revision, which may or not be...
  35. Replies
    8
    Views
    2,162

    Unless the customer still has a service agreement...

    Unless the customer still has a service agreement with Siemens, they will probably gauge you on the price, and probably try to sell you a new server as well. They will need to add the server license...
  36. Yes it communicates through the mmi port, it is...

    Yes it communicates through the mmi port, it is very slow.


    Sent from my iPhone using Tapatalk
  37. Dadof5 My email is in my profile, email me with...

    Dadof5
    My email is in my profile, email me with questions.



    Sent from my iPhone using Tapatalk
  38. I've done it, not conventionally though as to all...

    I've done it, not conventionally though as to all jace driver options would not work. We had the customer purchase insight BACnet server and we made the insight server a glorified bacnet router.

    ...
  39. Replies
    3
    Views
    668

    No WCIS is for accessing TECs and other P1...

    No WCIS is for accessing TECs and other P1 devices.


    Sent from my iPhone using Tapatalk
  40. Replies
    4
    Views
    868

    Your best bet might be to call around and see if...

    Your best bet might be to call around and see if any other vendors may be able to help you manage the system. Unfortunately you are locked in to Siemens for true product support, but there are plenty...
  41. Nick is correct, remote notification is licensed,...

    Nick is correct, remote notification is licensed, and can only be purchased through your local Siemens branch.


    Sent from my iPhone using Tapatalk
  42. Replies
    14
    Views
    2,839

    Tridiumtech, I am currently working with Tridium...

    Tridiumtech,
    I am currently working with Tridium everyday. Thank you


    Sent from my iPhone using Tapatalk
  43. Replies
    14
    Views
    2,839

    I worked for Siemens for 10 years and left a year...

    I worked for Siemens for 10 years and left a year ago. With Siemens you will work 95% of the time on the apogee line. The only experience you will get with other venders will be through integration...
  44. Replies
    5
    Views
    983

    Do you have an insight front end. You can also...

    Do you have an insight front end. You can also view PPCL and point database from the system profile.
    These devices are dinosaur and Siemens decided years ago to make them difficult to use by...
  45. The Siemens to Lon integration is bulky and at...

    The Siemens to Lon integration is bulky and at this point obsolete. They are pushing you to go BACnet because of this. Siemens will price this job so BACnet makes more sense. $$


    Sent from my...
  46. Replies
    4
    Views
    824

    I believe the 550-530 tec is a Lon heat pump...

    I believe the 550-530 tec is a Lon heat pump controller.


    Sent from my iPhone using Tapatalk
  47. It is easier for Siemens to push you to go...

    It is easier for Siemens to push you to go BACnet. There are several different ways for them to achieve this. All of them costly. What are your concerns?


    Sent from my iPhone using Tapatalk
  48. Replies
    12
    Views
    2,326

    There a many different sequences to control your...

    There a many different sequences to control your dampers. Simple control would be to control your economizer to maintain discharge are set point. You also have air quality control where you monitor...
  49. Replies
    7
    Views
    1,055

    These are Siemens apogee devices. You can do...

    These are Siemens apogee devices. You can do everything you need with the PXC controller. Unfortunately programming this will not be easy, for someone not familiar with PPCL, especially thru hyper...
  50. Replies
    8
    Views
    2,162

    I the research I have done is that the driver is...

    I the research I have done is that the driver is p1 devices only. I needed to install Siemens bacnet server and use the insight machine as a "gateway" in order to make this work.


    Sent from my...
Results 1 to 50 of 258
Page 1 of 6 1 2 3 4