Search:

Type: Posts; User: IceDoctorII

Search: Search took 0.01 seconds.

  1. Replies
    9
    Views
    444

    Actually it uses a proximity switch.

    Actually it uses a proximity switch.
  2. Replies
    14
    Views
    555

    The diaphragms in Manitowoc water valves tend to...

    The diaphragms in Manitowoc water valves tend to rot from all the chemicals in the water over time. Once they leak onto the stem area they tend to not always close. They tend to dry out after the...
  3. Replies
    14
    Views
    555

    Replace inlet valve. Go on to next job.

    Replace inlet valve. Go on to next job.
  4. Replies
    7
    Views
    378

    Try Sears parts direct. Franklin ice machine

    Try Sears parts direct. Franklin ice machine
  5. Replies
    15
    Views
    634

    Better check the flux capacitor.

    Better check the flux capacitor.
  6. Replies
    64
    Views
    2,381

    There is a fireman vest that circulates ice water...

    There is a fireman vest that circulates ice water seems to me about 6 bills
  7. Replies
    2
    Views
    219

    Not related but dump valve is #1 cause of blown...

    Not related but dump valve is #1 cause of blown fuses followed by water pump.
  8. From what you have said I believe the controller...

    From what you have said I believe the controller has a bad relay.
  9. Is the dome of the compressor cold at the end of...

    Is the dome of the compressor cold at the end of freeze?
  10. your freeze cycle is to short. Increase bridge...

    your freeze cycle is to short. Increase bridge thickness.
  11. What is the actual time between start of harvest...

    What is the actual time between start of harvest and ice falling off the plate? How long does it take to freeze a batch of ice? No water should go thru condenser during harvest. Does the curtain...
  12. Replies
    30
    Views
    26,548

    How about scrubbing evap with Scotsman cleaner

    How about scrubbing evap with Scotsman cleaner
  13. Replies
    10
    Views
    1,320

    Be sure they gave you the right part. They now...

    Be sure they gave you the right part. They now have many valves instead of the simple 2 or 3. There is no universal 115v or 230v. The right valve should have the correct brackets.
  14. Replies
    24
    Views
    3,753

    Freeze ups may not be warranty depending on...

    Freeze ups may not be warranty depending on cause. If caused by not being cleaned in 2 years - lots of luck.
  15. Replies
    19
    Views
    2,848

    Try Q320. Y denotes cube size.

    Try Q320. Y denotes cube size.
  16. Replies
    27
    Views
    3,917

    Did you mount the TXV with the dome up?

    Did you mount the TXV with the dome up?
  17. Replies
    26
    Views
    2,314

    High pressure control is in series with contactor...

    High pressure control is in series with contactor coil. High Temp Safety is wired with harvest area.
  18. Replies
    26
    Views
    2,314

    Don't know why the contactor would trip but have...

    Don't know why the contactor would trip but have seen the harvest motor attempt to run backwards which would cause the harvest to last about a half a second.
  19. Replies
    46
    Views
    8,046

    If you are in a small town or rural area be...

    If you are in a small town or rural area be prepared for both. HVAC becomes more refrigeration every day.
  20. Replies
    7
    Views
    1,555

    Don't guess - check sequence of operation and...

    Don't guess - check sequence of operation and find what is not happening. I would pay special attention to the high temp safety.
  21. Get used to it-deal with it or change...

    Get used to it-deal with it or change professions. It's part of commercial service.
  22. Replies
    33
    Views
    4,760

    You expect a tech to admit he made a mistake? ...

    You expect a tech to admit he made a mistake? Only old geisers who have nothing to loose will admit to have done something less than perfect.
  23. Replies
    18
    Views
    2,073

    Sounds like the magnet broke off leaving just the...

    Sounds like the magnet broke off leaving just the stem remaining. It is about 3/8
  24. Replies
    21
    Views
    2,967

    Don't call the machine names - it will just get...

    Don't call the machine names - it will just get even. After cleaning the probe including the plastic- rinse it thoroughly in fresh clean water and reasonably dry including the wire and your problem...
  25. Thread: Aspen 416

    by IceDoctorII
    Replies
    10
    Views
    1,753

    Who does it help when it is only cheaper? Use...

    Who does it help when it is only cheaper? Use what works and stick with it. The customer respects you more for quality than cheap.
  26. Replies
    33
    Views
    5,864

    HP81 replaced 502 in Manitowoc ice machines. ...

    HP81 replaced 502 in Manitowoc ice machines. Dupont MP39 for R12 AND CHANGE txv
  27. A lot of vital parts have been discontinued for...

    A lot of vital parts have been discontinued for the undercounter B models take care not to thro good money after bad.
  28. Replies
    14
    Views
    2,375

    300 is a long way from 1400.

    300 is a long way from 1400.
  29. Thread: Manitowoc

    by IceDoctorII
    Replies
    13
    Views
    2,535

    I would suggest thoroughly checking/replacing the...

    I would suggest thoroughly checking/replacing the on-off switch. When they get bad connections internally they can cause wierd/ intermittent problems.
  30. Replies
    11
    Views
    1,780

    I bet it mostly happens on fridays at 4pm!

    I bet it mostly happens on fridays at 4pm!
  31. Replies
    20
    Views
    2,708

    You can do a lot of things that you think will...

    You can do a lot of things that you think will fix the problem but the simplest solution is to raise the water level to 1/2 in above the water pump and put the front panel back on. The problem will...
  32. Replies
    6
    Views
    961

    The "B" machine is older style with a float valve...

    The "B" machine is older style with a float valve where as the "Q" machines are batch fill and more water efficient.
  33. Replies
    62
    Views
    5,892

    Try drying off the evap with a heat gun to check...

    Try drying off the evap with a heat gun to check for scale. Check and make shure the weep holes are not plugged.
  34. Replies
    31
    Views
    3,148

    Did you use all OEM parts? (Compressor, TXV, Fan...

    Did you use all OEM parts? (Compressor, TXV, Fan Cycle and LL drier)
  35. Replies
    10
    Views
    1,417

    Kinda like PPV.

    Kinda like PPV.
  36. Replies
    20
    Views
    6,802

    my advise - go it alone and be careful of who and...

    my advise - go it alone and be careful of who and if you give credit.
  37. Replies
    18
    Views
    2,948

    how about turning the water off to the machine...

    how about turning the water off to the machine after the second fill until it enters harvest?
  38. Replies
    23
    Views
    3,716

    Does it have a defrost termination thermostat?

    Does it have a defrost termination thermostat?
  39. Replies
    13
    Views
    1,493

    The POE oil is doing a good job of cleaning the...

    The POE oil is doing a good job of cleaning the system and causing debris to travel around in the system. Also high head pressure due to dirty condenser may be causing oil breakdown. Be sure to...
  40. Replies
    7
    Views
    1,519

    Some Danfoss TXV are required to be mounted with...

    Some Danfoss TXV are required to be mounted with head up. I would sugest checking with the manufacturer. Some will cause irratic feeding if mounted horizontally.
  41. Replies
    5
    Views
    1,482

    The energy savings and the piece of mind are...

    The energy savings and the piece of mind are worth the professional. Don't let a few dollars cause you to have a hacked up system. A proper sized and installed system will provide years of trouble...
  42. Replies
    13
    Views
    4,733

    Hot Shot and One shot are not the same-

    Hot Shot and One shot are not the same-
  43. Replies
    22
    Views
    2,860

    Bury it - don't marry it!

    Bury it - don't marry it!
  44. Replies
    17
    Views
    1,820

    How about a complete model #?

    How about a complete model #?
  45. Replies
    14
    Views
    3,518

    Coils on the new mani dump valves are polarized. ...

    Coils on the new mani dump valves are polarized. Current will only flow one direction.
  46. Thread: White ice

    by IceDoctorII
    Replies
    18
    Views
    2,522

    White ice in a commercial ice machine nearly...

    White ice in a commercial ice machine nearly always indicates a water starvation or tracking problem. Suggest you contact your local Manitowoc Distributor reference a service bulletin that discusses...
  47. the servend thermistor also serves as a high...

    the servend thermistor also serves as a high temperature safety for the evap. use a clamp on type klexon thermostat that opens about 90 degrees F wired in series with the dump valve and hot gas...
  48. Replies
    12
    Views
    1,463

    Could be a form of 3ph protection?

    Could be a form of 3ph protection?
  49. Replies
    9
    Views
    1,180

    If your pressures are normal during harvest could...

    If your pressures are normal during harvest could be txv is not opening?
  50. Replies
    21
    Views
    5,001

    You have invested way to much time on this...

    You have invested way to much time on this machine. Replace hot gas valve with OEM and collect your money.
Results 1 to 50 of 50

Related Forums