  1. Replies
    32
    Views
    4,107

    I banked hours for years. It requires trust in...

    I banked hours for years. It requires trust in your employer and to be honest it probably is not the smartest thing to do. It is your money and if you were to take your extra money and invest it for...
  2. Replies
    54
    Views
    5,166

    We install tx valves on every Goodman AC.We have...

    We install tx valves on every Goodman AC.We have been told that the seer rating is with a piston but the system with 10 degree sub cooling will maintain coil temperature when cooling evening...
  3. Replies
    27
    Views
    2,319

    This was a normal practice when we had belted fan...

    This was a normal practice when we had belted fan motors and questionable duct work. The larger coil should give you higher suction pressure and higher super heat.It seems that you either have a air...
  4. I only have 4 or 5 hours today reading posts ( I...

    I only have 4 or 5 hours today reading posts ( I skipped 15 pages) If I was as rich as I should be I would drive down see you and look at this problem. This is like losing a book with 3 pages left....
  5. Thread: Return air ?

    by jbooker56
    Replies
    5
    Views
    522

    Do your self a favor and call a professional....

    Do your self a favor and call a professional. This doesn't sound a system that ever had a chance of working properly and may even be dangerous.
  6. Replies
    6
    Views
    572

    to little too late

    I could not agree more.At this point with these furnaces you would need to isolate furnaces from from room and introduce plenty of outside air for combustion.
  7. Replies
    6
    Views
    2,107

    Probably too late but I ran into basically the...

    Probably too late but I ran into basically the same problem on a bryant furnace with similar board. Limit and reset checked out but still had code 13. Found the problem was in the exhaust system with...
  8. Replies
    6
    Views
    2,107

    I feel bad that I have nothing for you. In the...

    I feel bad that I have nothing for you. In the back of my mind I am almost sure I have had the same thing before and I would love 10 minutes with the furnace. please let me know when you beat it'
  9. Replies
    29
    Views
    2,985

    We do a high eff. furnace, waterheater with new...

    We do a high eff. furnace, waterheater with new chimney or powervent,ac new install or replacement,in a day. This is two men plus electrician who also works with crew. Material is already each...
  10. Replies
    6
    Views
    2,107

    I only found a poor wiring diagram but it looks...

    I only found a poor wiring diagram but it looks like there is a resetable flame roll out switch in the limit circuit.
  11. Replies
    23
    Views
    4,021

    I havent been to school on this since 1968 but 0...

    I havent been to school on this since 1968 but 0 super heat to me means a fully flooded evapourator pulling max heat from system.Super heat is for compressor safety not efficiency. Have I missed...
  12. Replies
    6
    Views
    2,805

    If you think basics, hot air rises so if you are...

    If you think basics, hot air rises so if you are heating a large part of the year a return at floor level will pull hot air through a room, assuming floor registers at outside walls and returns on...
  13. Replies
    57
    Views
    3,859

    I imagine you are reasonable confused so I will...

    I imagine you are reasonable confused so I will add a couple of points.It seems like a lot of furnace for your area. This may be to get enough blower to run 4 tons of ac. I would agree with others...
  14. Replies
    4
    Views
    523

    Call a serviceman to check control wiring.

    Call a serviceman to check control wiring.
  15. Replies
    12
    Views
    660

    It sounds like the gasket on the low side is...

    It sounds like the gasket on the low side is loose and stuck. Try taking the handle apart and see if a screw has come out of the end from over tightening gauges. I used to have this happen with some...
  16. Replies
    5
    Views
    2,998

    I agree it is probably thermostat. I have seen...

    I agree it is probably thermostat. I have seen one this year that was heating internally but it never shut off. It seems the cheaper the thermostat the stranger the problems.
  17. Replies
    76
    Views
    4,167

    This may seem a little simple but as I do not...

    This may seem a little simple but as I do not know where you live I often ask people if their old furnace ran steady on the coldest days of the year. It does not bypass load calculations but is a...
  18. If you have a air handler or a furnace the paper...

    If you have a air handler or a furnace the paper could be wrapped on the blower wheel or be blown to bottom of the a coil. if it is on the wheel it may cause balance problems and or reduce air flow....
  19. It sounds like you have answered your own...

    It sounds like you have answered your own question. Looking at your list and doing a quick labour calculation it would seem you would not be doing your customer a favour but what can you do when the...
  20. ecm motors

    I find this very interesting. Is it possible you could give more information on where the rule of thumb comes from. Jim
  21. I changed my 200th plus compressor today....

    I changed my 200th plus compressor today. Nitrogen, recover machine,warranty slips,welded stubs on old compressor, three hours. I used to do them in an hour but now I get to save a planet. lol
  22. Thread: new member

    by jbooker56
    Replies
    6
    Views
    904

    more pulse

    I was also thinking as I wrote about the pulse furnace ,how with a variable speed motor on board it would still be a pretty good furnace. It was an interesting start for me as the first pulse I...
  23. Thread: new member

    by jbooker56
    Replies
    6
    Views
    904

    ancient history

    That thank you seems a poor way to get a posting. I am a serviceman with Centennial Plumbing and heating in Saskatoon the fastest growing city in Canada. We specialize in service and furnace, Ac...
  24. Thread: new member

    by jbooker56
    Replies
    6
    Views
    904

    new member

    Thankyou This is very helpfull Jim
  25. Thread: new member

    by jbooker56
    Replies
    6
    Views
    904

    new member

    Hi With 40 years in the heating and Ac installation and service business I can safely say one can never stop learning. I can see this is the right place to be but I need to get to the other pros. I...
Results 1 to 25 of 26