  1. Replies
    50
    Views
    1,372

    Form over function.

    Form over function.
  2. Replies
    50
    Views
    1,372

    The one nest I ever torched was on a carrier gas...

    The one nest I ever torched was on a carrier gas furnace horizontal. Pressure switch leads sandwiched against the metal box the power comes in through. With some fine needle nose work I shorted...
  3. So not a SLP98?

    So not a SLP98?
  4. Replies
    8
    Views
    321

    most no-heat call I go to have clean filters ...

    most no-heat call I go to have clean filters :whistle:
  5. Replies
    44
    Views
    1,704

    Maybe they are needed for more severe operating...

    Maybe they are needed for more severe operating conditions, a more robust and reliable design for ambient conditions, but im sure there will be an answer coming that is spot on.
  6. Replies
    44
    Views
    1,704

    Let me be the first to say I dont know. Did have...

    Let me be the first to say I dont know. Did have a sparker shorting out on the housing one time failing to ignite.
  7. Replies
    31
    Views
    2,182

    Very nice. I do have a Bluetooth obd2 scanner...

    Very nice. I do have a Bluetooth obd2 scanner that stays plugged in. Have an app on the tablet that warns me of code faults before they turn on the light. Also real time instrument cluster...
  8. Loose or missing grommets in between blower...

    Loose or missing grommets in between blower housing, or blower removal rubbing over wires. I think its a carrier that used to mount pressure switch sandwiched on power supply cover. Learned that...
  9. Replies
    64
    Views
    2,146

    I did confirm a high limit shutdown yesterday. ...

    I did confirm a high limit shutdown yesterday. It was a 90 day media filter going on a year. Heh
  10. Replies
    64
    Views
    2,146

    Have extra motors on hand. Lol

    Have extra motors on hand. Lol
  11. Replies
    64
    Views
    2,146

    Capacitor sizing and parallels are good. Low...

    Capacitor sizing and parallels are good. Low Voltage during particular hp operation. Whats a relay and how can I avoid learning them. The capacitor will not fit in the provided strap, use tape,...
  12. Replies
    31
    Views
    2,182

    No injuries. Wet, dark, very sharp corner. ...

    No injuries. Wet, dark, very sharp corner. Went into ditch pitched left rolled onto side and slid to a stop. Two wreckers had to pull it up and out in unison. State trooper said I exceeded a...
  13. Replies
    31
    Views
    2,182

    I rolled my transit connect in a ditch. Fun call...

    I rolled my transit connect in a ditch. Fun call to fleet service.
  14. Replies
    14
    Views
    1,867

    my 760 is installed as manufacturer recommends,...

    my 760 is installed as manufacturer recommends, but what happened when the t-former on the board failed? I had to get creative with controls.
  15. Replies
    9
    Views
    675

    Ss2 seems to be our go to. The only time I see...

    Ss2 seems to be our go to. The only time I see problems is when installers put them in improperly.
  16. I had to contact manufacturer to see the ohm...

    I had to contact manufacturer to see the ohm value should be to the corresponding oat. Lennox thing....
  17. get your post count up and apply for pros status....

    get your post count up and apply for pros status. Cannot give detailed technical support out in open forums.
  18. Are you going to feed 24v to the 700?

    Are you going to feed 24v to the 700?
  19. Usually find them where they are zip tied to the...

    Usually find them where they are zip tied to the copper. Found one where guys putting up a radient barrier pierced the t-stat wires. I had to remove alot of it.
  20. Replies
    8
    Views
    222

    Tighten everything.

    Tighten everything.
  21. Replies
    15
    Views
    536

    Well its laryngitis. First doc gave me amox to...

    Well its laryngitis. First doc gave me amox to treat a virus.....nice. second doc said, "we are gonna give you strong cough syrup since hacking your guts up wont help inflammation". They took...
  22. Replies
    15
    Views
    536

    Required PPE yes. In truck, No. I have a loaner...

    Required PPE yes. In truck, No. I have a loaner truck right now, so kinda my fault. I did wear during duct installs and cleans.
  23. Replies
    15
    Views
    536

    Web MD has the audacity to list Anthrax as the #2...

    Web MD has the audacity to list Anthrax as the #2 possible cause.... HA!
  24. Replies
    47
    Views
    2,304

    Bats on the id coil. Decomposed. HO said there...

    Bats on the id coil. Decomposed. HO said there was an odd smell over the summer. I thought it was insulation when I retrieved it. Ugh.
  25. Feel you pain with Lennox.

    Feel you pain with Lennox.
  26. Replies
    15
    Views
    536

    strange illness

    Well I started with a severe cough leading to inflammation of the vocal cords. No other symptoms. Now a week later cough persists, very little chest congestion, low grade fever, fatigue, body...
  27. Replies
    16
    Views
    775

    No not aluminum. Over the summer I ran many...

    No not aluminum. Over the summer I ran many calls 1st year on rheem packs.
  28. Replies
    17
    Views
    2,912

    Had a carrier pack yesterday with Swiss cheese...

    Had a carrier pack yesterday with Swiss cheese HX. Priced repairs, out of warranty, HO wanted me to weld it up. 99 pack, recommended replacement, have not heard back. Would like to know what he...
  29. Replies
    6
    Views
    1,540

    Mighty putty.

    Mighty putty.
  30. Replies
    17
    Views
    2,912

    Bypassed door switch. Classic. I actually raid...

    Bypassed door switch. Classic. I actually raid the scrap pile for those things just in case they are missing, but they usually turn up near the unit. Underneath....
  31. Replies
    26
    Views
    2,382

    Have a lady with a Lennox pure air kit who has to...

    Have a lady with a Lennox pure air kit who has to change it every six months. Suck it up and smoke outside. Too expensive to change that frequently.
  32. Replies
    16
    Views
    775

    leakers+txv+x13=ugh :gah:

    leakers+txv+x13=ugh :gah:
  33. Replies
    53
    Views
    3,547

    Auto changover on a second floor breezeway. Gas...

    Auto changover on a second floor breezeway. Gas logs. You know where this is going
  34. Replies
    53
    Views
    3,547

    yup. done that.

    yup. done that.
  35. Replies
    30
    Views
    1,752

    It's one of those units that defy logic and...

    It's one of those units that defy logic and reason. More the reason to keep her running. Is that some kind of Carrier?
  36. Replies
    4
    Views
    289

    Pipe clamp thermo

    Any suggestions of a DURABLE pipe clamp thermocouple? Gonna get what i pay for? Plastic jaws either snap at the spring, or wires become loose. I'm sure this topic has been beaten to death :gah:
  37. Replies
    6
    Views
    753

    Nice to see that particular unit not pinned to a...

    Nice to see that particular unit not pinned to a house for a change.
  38. Recommend a uv light to help keep the snakes to a...

    Recommend a uv light to help keep the snakes to a minimum, hah
  39. Replies
    3
    Views
    430

    I see alot of cases where throwing VB, and...

    I see alot of cases where throwing VB, and dehumidifiers "just for the spiff of it" is believed to be the cure all. I ask is this a little residual moisture, or is this a poor drainage/grading issue...
  40. Replies
    3
    Views
    430

    Spray foam crawl

    My last call of the night was to get an Aprilaire de-hum up and running. The crawl had been spray foamed in place of fiberglass batting. The vapor barrier was sparse, and the vents were opened. ...
  41. What was the heat and cool supply vent about? ...

    What was the heat and cool supply vent about? Was it a damper he was talking about? Or was he referring to closing supply vents?
  42. Replies
    9
    Views
    715

    Sorry correction, this is an LP setup. Had 6.58...

    Sorry correction, this is an LP setup. Had 6.58 iwc on low running 39960 btuh of 54000. After reading the manufacturers nomenclature i found this=
    Units fueled by LP/propane gas are rated for...
  43. Replies
    9
    Views
    715

    Outlet 1.83 iwc on low fire.

    Outlet 1.83 iwc on low fire.
  44. Replies
    40
    Views
    2,630

    Have the fluke combo. Only complaint was the...

    Have the fluke combo. Only complaint was the temp adapter stopped working. Really like the retractable leads.
  45. Replies
    7
    Views
    468

    This was one of two returns. It was an upstairs...

    This was one of two returns. It was an upstairs 12x12..... it was a 2 ton brand new cbx25uh. Had one of those 3M 16x25x1 static killer on the other return. I told her to visit filter easy website...
  46. Replies
    7
    Views
    468

    indoor air quality is always on the back burner.

    indoor air quality is always on the back burner.
  47. Replies
    7
    Views
    468

    Dirty filter contest?

    Temporary filter 12x12 circa 2005 :eek2:515691
    HO said nobody ever asked to check the filter upstairs.
  48. Replies
    9
    Views
    715

    Oh will do. Thinking if the high fire solenoid...

    Oh will do. Thinking if the high fire solenoid is energized but not working inducer will not ramp up either. Its a 15GCSX series btw
  49. Replies
    9
    Views
    715

    Was on the phone with lennox tech support, they...

    Was on the phone with lennox tech support, they quickly told me to replace the valve and they have seen this before. Of course I did check t-stat setup, wiring, and gas pressure.
  50. Replies
    9
    Views
    715

    No fuse. Call for hi fire, voltage present at...

    No fuse. Call for hi fire, voltage present at common and hi, but no high fire.