Search Results - HVAC-Talk: Heating, Air & Refrigeration Discussion

Search:

Type: Posts; User: safwan

Page 1 of 3 1 2 3

Search: Search took 0.00 seconds.

  1. Thread: CAV & VAV

    by safwan
    Replies
    1
    Views
    317

    CAV & VAV

    What is diffrence between CAV & VAV ?

    I mean by VAV, Temperature is achieved by controlling pressure, but in case of CAV there is no pressure...then how temperature is achieved.
  2. Thread: CASCADING

    by safwan
    Replies
    1
    Views
    262

    CASCADING

    Hey...Guys.

    Just wanna know...how cascading is achieved by using a one VFD going for 6 secondary pumps.
  3. Replies
    1
    Views
    426

    963 Supervisior- Trend Controls

    Hi Folks,

    How to take the reference of Graphs in 963 supervisor from the Controller.
  4. Replies
    2
    Views
    292

    TREND CONTROLS & CARRIER GTN100

    Hi folks,

    Got a glitch for integrating Carrier GTN100-series chiller of quantity 2 along with Graphics.

    firstly need to know GTN100 chiller communicating protocol....is it MODBus or BACnet ?
    ...
  5. Replies
    2
    Views
    676

    TREND CONTROLS - THERMOSTAT

    Hi...folks,

    got a problem in selecting the thermostat for package units.... there is One DPG which compromises of 3-PACU serving different zones.

    I had selected the IQ3 controller along with IO...
  6. Replies
    2
    Views
    262

    TREND INTERFACES.........

    Did anyone have information about the Trend Interfaces by Eelctrocom (http://www.electrocom.dk/2-home.html ?

    Any Information ?
  7. Replies
    1
    Views
    432

    TREND LAN NETWORK

    Hi Folks,

    I am estimating one project which consist of 3 floor with 15 DDC Panel on each floor & 501-Third Party BACnet MS/TP Networkable FCU's ....as this project was installed as standalone...
  8. Replies
    2
    Views
    606

    Thanks Denhvax....you can find the my email...

    Thanks Denhvax....you can find the my email address in my profile....iam waiting for your mail.
  9. Replies
    11
    Views
    1,197

    OK Agreed.....But if iam gonna use...

    OK Agreed.....But if iam gonna use IQ3XCITE/128/BAC/24 or/230 for each panel. i had to use the network switches in each building and to connect workstation, i had to use fiber optic cable to connect...
  10. Replies
    2
    Views
    606

    TREND CONTROL- VISIO STENCILS

    Does anyone have visio stencils of Trend controls ? As i have to used in risers.....and dont wanna go for Autocad models.
  11. Replies
    11
    Views
    1,197

    IQ3/LAN -TREND CONTROLS

    Hi Guys,

    Iam estimating a Project which consist of 4 buildings with 10 DGP Panels each, the distance of each is building is >200<250 meters to other.Iam considering IQ3XCITE/128/LAN/240...
  12. Replies
    4
    Views
    536

    TREND CONTROLS UPGRADE

    Hi folks.......Need Help.

    I got an inquiry which compromises 300-FCU's and 16-AHU'S which is working as standalone system, but based on a product TAC Vista LON Controls.the client do not want to...
  13. Replies
    4
    Views
    607

    Thanks Orion.........for sharing this...

    Thanks Orion.........for sharing this information.....But again....I had a glitch regarding the Thermostats.

    Agreed....As per your information for TB/TS means, it require hardware inputs such as...
  14. Replies
    4
    Views
    607

    Trend IQVIEW & IQECO

    Hi Folks........Need information based on Iqview & Iqeco.

    There is 3 Types of IQVIEW series..........as IQVIEW, IQVIEW4 & IQVIEW8.

    IQVIEW : IQView display that provides a self-configuring user...
  15. Thread: TREND CONTROLS

    by safwan
    Replies
    5
    Views
    824

    Need More........Elaboration dude.

    Need More........Elaboration dude.
  16. Thread: Trend Honeywell

    by safwan
    Replies
    9
    Views
    1,371

    Thanks for the Information......Yes Iam working...

    Thanks for the Information......Yes Iam working on Trend as Newbie on this Product.
  17. Thread: Trend Honeywell

    by safwan
    Replies
    9
    Views
    1,371

    Iam Proposing 963S in a Project which will be...

    Iam Proposing 963S in a Project which will be installed in workstation and can also be used as 3 web seats. Once the software in installed in workstation with license , can install this software with...
  18. Thread: Trend Honeywell

    by safwan
    Replies
    9
    Views
    1,371

    Trend Honeywell

    Hi Folks....

    Got a glitch for selecting the Operator software.

    For a Workstation i had selected "963S/CD/3USER" 963 server plus 3 web clients. I need to do standalone T&C through local Laptop,...
  19. Replies
    1
    Views
    393

    Trend Damper : ADS10-P, ADS20-P

    Hi guys.....I need to know about this Floating/Modulating dampers, that If Iam considering the Dampers ADS10-P, ADS20-P , Does Auxiliary Switch " ACCA-AD2034-SW2 " is essential for this ?

    As I...
  20. Replies
    2
    Views
    699

    KMC BACstage file have a extension of .BAC files,...

    KMC BACstage file have a extension of .BAC files, first check whether it can work with .bac files.iam sure if it is bacnet compatible it can work with both BACstage and Total Control.
  21. Replies
    6
    Views
    770

    Trend Third Party

    Is the other workstation is neccessary with equivalent to BMS workstation, if we are using the third party integration for "TONN" gateways.
  22. Replies
    3
    Views
    590

    Man Days Engineering

    Hi folks,

    How do i consider the man days engineering for the control & Monitor for the following machines.

    1.AHU'S
    2.CHILLERS
    3.FAN COIL UNITS
    4.VAV'S
    5.PACU
    6.PLUMBING SYSTEM
  23. Thread: Trend controls

    by safwan
    Replies
    5
    Views
    1,168

    yes they offer the ECO-VAV-PA here. Is it a...

    yes they offer the ECO-VAV-PA here.

    Is it a networkable controller with a full options for Pressure independent and Pressure dependent ?
  24. Thread: Trend controls

    by safwan
    Replies
    5
    Views
    1,168

    Trend controls

    Hi Everyone,

    Started working on Trend Product, I had a glitch regarding the selection of FCU & VAV Controllers, as the points to be controlled and monitor has not been given by client, as for the...
  25. Replies
    3
    Views
    1,071

    Honeywell Comfort Point Programming Software

    I need Comfort point programming software for Honeywell...............does any one have or any link.
Results 1 to 25 of 59