Search Results - HVAC-Talk: Heating, Air & Refrigeration Discussion

Search:

Type: Posts; User: season0174

Search: Search took 0.00 seconds.

  1. Replies
    21
    Views
    1,802

    Mwahahaha~ Awesome one XD you have lunch yet?...

    Mwahahaha~ Awesome one XD

    you have lunch yet?

    It's 12:45am here~ time to get bed

    Have a nice day, frank....=]

    and....nite~Zzzzzzzz
  2. Replies
    21
    Views
    1,802

    halo guys~ Nighty-night =]

    halo guys~
    Nighty-night =]
  3. Replies
    21
    Views
    1,802

    ha~ morning with only the nickname shown, i...

    ha~ morning
    with only the nickname shown, i don't think i know who's CAN
  4. Replies
    21
    Views
    1,802

    yup~~ =] Time is now 6:39am

    yup~~ =]

    Time is now 6:39am
  5. Replies
    21
    Views
    1,802

    http://www.york.com/products/esg/servicelit/ywpubs...

    http://www.york.com/products/esg/servicelit/ywpubs/160.54-M1.pdf

    section22A - Page 165
  6. Replies
    21
    Views
    2,676

    Agree.... totally, absolutely, utterly... there...

    Agree.... totally, absolutely, utterly...
    there are just too many reasons caused the chiller surging.

    System got air in
    Condenser Condition
    Cooler Condition
    Water Temp.
    System charge
    VSD's...
  7. Replies
    7
    Views
    1,974

    Read these... so just don't care.... ...

    Read these... so just don't care....

    http://www.aboutammoniarefrigeration.com/aaranswers_environmental.cfm

    http://www.ashrae.org/content/ASHRAE/ASHRAE/ArticleAltFormat/200622793710_347.pdf
    ...
  8. Replies
    2
    Views
    912

    Try re-calibrating it.... go "Compressor" page...

    Try re-calibrating it.... go "Compressor" page with Service Level
  9. Replies
    3
    Views
    825

    oh~ then it doesn't matter with the LED, i think...

    oh~ then it doesn't matter with the LED, i think you just have to check the sensors...

    boot-up is ..... no any graphic's showing in the panel, but a white screen and texts --- like
    -- Mini-card...
  10. Replies
    3
    Views
    825

    It's a Boot-up Fail LED. it keeps flashing if any...

    It's a Boot-up Fail LED. it keeps flashing if any step of the "boot-up sequence" fails , how many of it is flashing, shows which step goes wrong.
    it illuminates or extinguishes when boot-up...
  11. Replies
    3
    Views
    625

    5/8" (inner size I mean, and the brushes we use),...

    5/8" (inner size I mean, and the brushes we use), so, 3/4" Ti , Cu, or CuNi tubes~ 100% for York Water cooled chillers. (btw I'm not a sales guy :D)
    ...
  12. Replies
    5
    Views
    650

    I think that's not a York's product. In the...

    I think that's not a York's product.

    In the "YK field" I've been working for almost 6yrs. and have never seen that thing.

    We just put Loctite 554 on transducers' and some valves' threads.
    ...
  13. Replies
    28
    Views
    1,823

    Yer. Think so. Tommy>> does your machine have...

    Yer. Think so.

    Tommy>>
    does your machine have sth like "pump down solenoid" or any valves before the compressor suction
    just check if it's closed or unenergized.
  14. Replies
    23
    Views
    2,566

    http://www.york.com/products/esg/ServiceLit/ywpubs...

    http://www.york.com/products/esg/ServiceLit/ywpubs/160.47-PW1.pdf
    http://www.york.com/products/esg/ServiceLit/ywpubs/160.47-O1.pdf

    Are you looking for these?
  15. Replies
    3
    Views
    787

    [SIZE="4"] Yes, ribbon cable error may cause...

    [SIZE="4"]

    Yes, ribbon cable error may cause the display keep turning on and off.
    but sorry, i dun think it can happen sth just like "Control Power Failure".

    "Power Failure" just could be...
  16. Replies
    16
    Views
    2,771

    the007>> I really WANTED to know that, because...

    the007>>
    I really WANTED to know that, because we are not doing something just like repairing, startup or maintenance, but like cannibalization stuff. (relocat a compressor or control panel from A...
  17. Replies
    16
    Views
    2,771

    HEY~that means you have one machine's Admin...

    HEY~that means you have one machine's Admin password for just one day? if so, how would you like to exchange with me? maybe we can figure it out.:eek:
    if you have interest, please email me....
  18. Replies
    16
    Views
    2,771

    Randy S. >> Yes. Admin Almighty can "Clear Surge...

    Randy S. >>
    Yes. Admin Almighty can "Clear Surge Count". Unfortunately only admin can do that.

    For more details, search "Admin" in Operation Manual 160.54-O1

    b-man>>
    Sounds quite right, but...
  19. Replies
    16
    Views
    2,771

    YK Optiview Control Panel Password

    does anyone know sth about the password of the "admin" level? how to calculate it. it's changing everyday. so, i think it must be related with the DATE..........and something else?
    ...