Search Results - HVAC-Talk: Heating, Air & Refrigeration Discussion

Search:

Type: Posts; User: targetman

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    1
    Views
    115

    Need Trane service facts

    Thanks in advance.
  2. Replies
    23
    Views
    585

    With ten years in the trade, you should get some...

    With ten years in the trade, you should get some credit for that. Some guys hire in at 2nd or 3rd year apprentice. Some guys like myself skip the apprenticeship.
  3. I have to disagree. It's not the lack of PM's or...

    I have to disagree. It's not the lack of PM's or people not doing there job on the PM. There is a real problem with 407C and bellows failures.
  4. Replies
    5
    Views
    391

    Thanks. I will check that out. I should have...

    Thanks. I will check that out. I should have titled my issue as migration instead of floodback. It's migration that I thought I was dealing with.
  5. Replies
    5
    Views
    391

    Carrier 38APD Liquid flood back

    Split system is about 5 years old. It has been plagued with low suction superheat alarms on both circuits since installation. I had nothing to do with the installation, but I know the guys that...
  6. Replies
    1
    Views
    156

    WSHP cleaning

    I'm looking for a pump for WSHP tube in tube coil cleaning. What do you guys use?
  7. Thread: B&G MF 60

    by targetman
    Replies
    4
    Views
    198

    B&G MF 60

    Maybe I'm missing something. I have a series 60 maintenance free bearing assembly that has been leaking for a year. Part # 185332. Another Tech in our company told the customer that we could...
  8. Replies
    9
    Views
    470

    Rotobrush is a scam.

    Rotobrush is a scam.
  9. Replies
    16
    Views
    2,035

    It's to bad that Fulton subs out tech support to...

    It's to bad that Fulton subs out tech support to the local rep.
  10. Replies
    71
    Views
    6,838

    Oxy/Acet

    Oxy/Acet
  11. Replies
    71
    Views
    6,838

    I use them on 7/8 OD with no problems.

    I use them on 7/8 OD with no problems.
  12. Thread: yaskawa vfd

    by targetman
    Replies
    10
    Views
    413

    Just Goggle Yaskawa z1000 quick setup.

    Just Goggle Yaskawa z1000 quick setup.
  13. Don't assume that your driving record will be an...

    Don't assume that your driving record will be an issue.
  14. Replies
    5
    Views
    523

    I think there was another recent thread about...

    I think there was another recent thread about this subject. Our company had two motors fail during construction of a building. Our Aaon rep sent there Tech out and changed the motors under warranty.
  15. Replies
    10
    Views
    941

    What is the model number?

    What is the model number?
  16. Replies
    22
    Views
    1,613

    I have used it on 410 installs and TXV...

    I have used it on 410 installs and TXV replacements. It will be fine.
  17. Replies
    18
    Views
    1,054

    New Tech maybe? I can remember making that same...

    New Tech maybe? I can remember making that same call for the same problem.
  18. Replies
    18
    Views
    1,054

    You have a wire rubbing somewhere. Check all low...

    You have a wire rubbing somewhere. Check all low voltage wiring in the outdoor unit. No need to call Carrier.
  19. Replies
    6
    Views
    426

    You could email me your contact info. I may be...

    You could email me your contact info. I may be able to help.
  20. Thread: Lennox G12

    by targetman
    Replies
    6
    Views
    373

    The church I was at today has four G12's. As...

    The church I was at today has four G12's. As long as they make heat, they won't replace them. Pilot is orifice is plugged and flame sensor and ignitor are falling apart.
  21. Thread: Lennox G12

    by targetman
    Replies
    6
    Views
    373

    Lennox G12

    Anyone got a source for a pilot burner.
  22. Replies
    18
    Views
    1,011

    You have to set regulators with flow. That's...

    You have to set regulators with flow. That's what the do is regulate flow. When the flow stops , they lock up and cease to flow.
  23. Thread: Square D

    by targetman
    Replies
    3
    Views
    329

    Thanks. Lots of good info.

    Thanks. Lots of good info.
  24. Thread: Square D

    by targetman
    Replies
    3
    Views
    329

    Square D

    What is up with Square D? I cannot get any info from the Schneider electric website. I have 5 combination motor starters that are screwed up. They were supplied wired as common control but have a...
  25. There is always a replacement compressor. It...

    There is always a replacement compressor. It might be a different brand compressor. Some piping changes may be required. But it can be done.
Results 1 to 25 of 500