    YKK makes a lot of different grades of zippers. ...

    YKK makes a lot of different grades of zippers. Veto does not appear to be using the highest quality one, although they have no qualms about having the highest priced bags. They should rethink...
  2. Replies
    0
    Views
    1,371

    NOVA 820 SIT VALVE

    I am curious about the combustion chamber compensation port on the bottom of these valves. 0820637 Since fireplaces don't have a combustion chamber, are there some brands of heaters where they are...
  3. Replies
    14
    Views
    1,966

    You either have a hot water boiler or a steam...

    You either have a hot water boiler or a steam boiler not both. There is no such thing. Steam boilers do not have circulator pumps. A hot water boiler should never operate at a temperature that...
  4. Replies
    10
    Views
    1,423

    RESIDENTIAL Life cycle/expectancy

    Can anyone direct me to a page or chart from a reputable source for finding the average life expectancy of split systems, furnaces, boilers, and heat pumps? I just need something simple for...
  5. Replies
    10
    Views
    694

    I don't know if its standard everywhere, but here...

    I don't know if its standard everywhere, but here the meters have an 1/8" pipe plug about 1" above the union on the outlet line. The regulator is ahead of the meter. The gas co. here has no problem...
  6. Replies
    10
    Views
    694

    There should be little change of pressure at the...

    There should be little change of pressure at the meter/pressure regulator unless it is overloaded or defective. Most regulators here only fluctuate about .5" under a load. Are you reading the...
  7. Replies
    15
    Views
    4,225

    Yeah, these big companies get this stuff approved...

    Yeah, these big companies get this stuff approved and then we find out years later it is unsafe. Kind of like aluminum wiring. Makes me not want to put my sticker on jobs for fear I'll get blamed...
  8. Replies
    15
    Views
    4,225

    Lightning risk for flex gas lines?

    Has anyone heard of this problem with flexible ss gas lines? I always hard-pipe gas lines, but have seen a lot of these on water heaters.
    ...
  9. Replies
    14
    Views
    1,396

    They have a MicroBlue coated fins for better...

    They have a MicroBlue coated fins for better water drainage, I don't know if it prevents formicary corrosion, that is the big problem now. I would like to hear from someone who has been using them....
  10. Replies
    11
    Views
    1,669

    Any restriction or blockage in system would give...

    Any restriction or blockage in system would give low suction. I'm not sure what you mean by "efficiency test", but if you closed a valve like the suction service valve or even a receiver outlet valve...
  11. Replies
    223
    Views
    7,930

    Poll: Thanks, never did.

    Thanks, never did.
  12. Replies
    223
    Views
    7,930

    Poll: I don't have the energy to read all 136 posts,...

    I don't have the energy to read all 136 posts, can anyone give me a condensed version of the answers :-)
  13. Replies
    14
    Views
    1,396

    I've only seen s.s. in laboratory equipment. The...

    I've only seen s.s. in laboratory equipment. The tin plated copper or all aluminum is supposed to prevent the formicary corrosion problem.
  14. Replies
    13
    Views
    2,005

    A big contractor here in town has used Staybrite...

    A big contractor here in town has used Staybrite for years, I have many of his customers after the food acids eat holes in it and they lose all their product. It is a low temp brazing material about...
  15. Thanks for the link Mark, I have been watching...

    Thanks for the link Mark, I have been watching threads about increasing failure rates on coils and felt it was due to the manufacturers' design. Now I can see where there are other causes that are...
  16. Replies
    117
    Views
    10,990

    LOL You must have ESP and ESPN :)

    LOL You must have ESP and ESPN :)
  17. Replies
    22
    Views
    3,147

    Thanks guys, I knew the conversion, I just didn't...

    Thanks guys, I knew the conversion, I just didn't read his statement carefully enough:o Very nice sensors though, I wish I'd heard about them a few years ago.
  18. Replies
    22
    Views
    3,147

    [QUOTE=chillerfreak;1819968]variable primary flow...

    [QUOTE=chillerfreak;1819968]variable primary flow is what is replacing constant primary/variable secondary systems. cost savings....one less pump and less piping as well as energy savings on reduced...
  19. Thread: Walk in freezer

    by ZZZRSC
    Replies
    12
    Views
    1,297

    I haven't done much refigeration in years but I...

    I haven't done much refigeration in years but I am pretty sure taking the cap off the cpr valve shouldn't make a difference in pressures. Also it should be set at the highest pressure the compressor...
  20. Replies
    22
    Views
    3,147

    I guess I don't understand the system, aren't you...

    I guess I don't understand the system, aren't you concerned the gpm's are so far away from design? Is this a variable speed chiller?
  21. Replies
    12
    Views
    1,177

    I worked at a facility that had a a similar...

    I worked at a facility that had a a similar problem about 6 years ago and the Trane tech came up with the same solution. I can't remember if it was on a RTAA, but we did replace one about that time....
  22. Replies
    12
    Views
    1,177

    I am thinking you are right about different...

    I am thinking you are right about different ground potentials, and that is why the shields are only connected at one end to prevent ground loop currents. Were the shields completely isolated from...
  23. Replies
    71
    Views
    5,291

    My customer isn't my boss. He is just someone...

    My customer isn't my boss. He is just someone wanting a service. Some are honest, some are theives, some are just plain ignorant. It's my job to sort them out and keep the good ones.
    Bad...
  24. Replies
    20
    Views
    1,286

    I believe R-22 will be around many years in it's...

    I believe R-22 will be around many years in it's modified version as sold by Icor as Nu-22 and Dupont as MO59?. There is a facility here in town with a dozen R-22 units less than 10 years old and...
  25. Replies
    28
    Views
    2,380

    Get a second opinion and pricing. Did he say the...

    Get a second opinion and pricing. Did he say the compressor was shot? The compressor could have serious damage,or not, running all day w/o refrig. What kind of warranty is in effect on this one...