  1. Thats one of those dehumidification systems,...

    Thats one of those dehumidification systems, cause contrary to popular belief it's not always a "Dry Heat"

    I'd say around 40 ST and Broadway
  2. Replies
    6
    Views
    527

    Yes you can have the unit moved away from the...

    Yes you can have the unit moved away from the home, and if they bury the line-set it needs to be in PVC. Talk with your installing HVAC contractor, since they did the original install the may give...
  3. Replies
    6
    Views
    527

    We use a lot of porta pads in new home...

    We use a lot of porta pads in new home construction here, and while they do seem to be a bit louder than a cement pad that usually only exterior noise. If you feel a vibration in the wall its most...
  4. ZONE WARS ! He he... I have experience with...

    ZONE WARS !

    He he... I have experience with Harmony, but not Infinity. The Harmony must be set up by an experienced tech, but is a great system once thats done correctly. I have heard nothing but...
  5. Replies
    19
    Views
    2,015

    Since you have just recently purchased this...

    Since you have just recently purchased this system, have you expressed your concerns to the installing contractor? Yes I believe most everything in this thread is accurate information (you do need a...
  6. Replies
    11
    Views
    908

    ewwwwwwwwwwww :( 'nuff said !

    ewwwwwwwwwwww :( 'nuff said !
  7. Replies
    6
    Views
    597

    Service Experts is a subsidiary of "Lennox...

    Service Experts is a subsidiary of "Lennox International" (i.e. LII), of which Lennox Industries (HVAC), Armstong, Ducane, Aire-Flo and several others are wholly owned subsidiarys as well.

    I had...
  8. Replies
    38
    Views
    2,250

    Yes I'm refering to the temp from return to...

    Yes I'm refering to the temp from return to supply. Your 35 degrees in gas seems in the ballpark, and I think the Maytag M1200 is two stage gas so this is probably first stage gas. The 11 degrees in...
  9. Replies
    38
    Views
    2,250

    The typical limit for variable speed blower motor...

    The typical limit for variable speed blower motor is .8 inches water column total system static, beyond that they begin to pulse and behave irradically.

    The heat rise depends on the unit but gas...
  10. Replies
    38
    Views
    2,250

    You need the installer to come out and check...

    You need the installer to come out and check several items. First is system static, which is the resistance to air flow through the duct system. My guess is your static is high, which reduces the...
  11. Replies
    19
    Views
    1,197

    The Harmony series of zone controls were designed...

    The Harmony series of zone controls were designed to work with a variable speed blower motor, go with the CBX32MV. It also has a 10 year warranty as opposed to 5 years on the CBX27. Same thing on...