  1. Do you see any issues with using zoning on a two...

    Do you see any issues with using zoning on a two stage vari furnace with a single stage cond that has Honeywell zoning where you can kick down the blower when only one zone is calling? Ive used this...
  2. I like in their instructions where it says " if...

    I like in their instructions where it says " if it looks right it probably is, talking about how to reassemble the machine". Never seen a manuf. say something like that about their product, most are...
  3. Replies
    64
    Views
    5,322

    Just got my digicools this monday with the add on...

    Just got my digicools this monday with the add on clamps. Gotta say i now regret not getting these years ago. Makes charging so much faster, accurate and easy and i compared them to brand new yj...
  4. I know I'm gonna get flak for this but i got...

    I know I'm gonna get flak for this but i got tired of using so many filters about five years ago for my recovery equipment. I have had the same appion twin for about four years now and never use...
  5. I used to use a form like that while working for...

    I used to use a form like that while working for one hour years ago and they still use it. That form will get you close like the others say but it is definitely not acca approved.
    I just got the...
  6. I like the manuf. charts as well but they are not...

    I like the manuf. charts as well but they are not for all scenarios. I do a lot of rheem and their chart is just like tranes above but if you look closer it says your db inside temp needs to be 80...
  7. Whats you suction pressures at before it trips? ...

    Whats you suction pressures at before it trips? Is there a charge chart on the panel of this unit that shows the pressures? Have seen many heat pumps that were weighed in be overcharged in heat...
  8. Replies
    64
    Views
    5,322

    Which manifold did you put on your DC?

    Which manifold did you put on your DC?
  9. Replies
    24
    Views
    1,557

    I have seen goodman, rheem, carrier and several...

    I have seen goodman, rheem, carrier and several others run the ibm with an open limit. I think most furnaces do that now. The funny thing is getting the call and the homeowners says "my blower has...
  10. Replies
    22
    Views
    1,145

    funny, Sonoma is the county i took the job in and...

    funny, Sonoma is the county i took the job in and learned about this code during installation.
  11. it probably won't ever be the norm because it...

    it probably won't ever be the norm because it costs more to have done and the cheap guys will never go there. It sure is nice going back on jobs ten years old that has it and the ducts are still...
  12. Replies
    22
    Views
    1,145

    Note sure where it is the only way i found out...

    Note sure where it is the only way i found out about it was when i went to pull a permit they brought it up. In my 16 years i have never heard about it either. If i get time ill call the county and...
  13. All i remove from homes around here is ductboard...

    All i remove from homes around here is ductboard plenums and wye's. you should see the homeowners face when i cut it open and show them what they have been breathing for 20 years. If you are worried...
  14. Replies
    22
    Views
    1,145

    You are exactly correct every county in know...

    You are exactly correct every county in know around me requires a propane drain pan whenever a propane gas fired appliance in installed in a basement. I did one of these and it is my last, had to...
  15. Thanks for the tip however the only reason i had...

    Thanks for the tip however the only reason i had this issue was because i bid the job before seeing it and won't be doing that again. I have been doing energy saving systems for homeowners for nearly...
  16. The biggest local company already installs resi...

    The biggest local company already installs resi water chillers called aquachill. They are very efficient but upfront cost, maintenance and subpar warranty makes them unattractive to most buyers. ...
  17. Update: the homeowner listened to reason once I...

    Update: the homeowner listened to reason once I got them away from their "expert" contractor. Part of my persuasion was to offer them a personal company guarantee that the system would cool to...
  18. Replies
    41
    Views
    2,840

    How many of you actually charge by the hour? ...

    How many of you actually charge by the hour?

    Myself and every company around here have flat rate tier pricing that never changes no matter what time of the day. Customers don't seem to like...
  19. Where did you get all the information from? Is...

    Where did you get all the information from? Is there some site that tells you that info for different areas? Our low humidity is nice most of the time but it makes you skin dry all winter because...
  20. Replies
    8
    Views
    750

    one company tried running aluminum linesets in...

    one company tried running aluminum linesets in our area, it was a massive failure.
  21. I have and don't usually use it unless i am...

    I have and don't usually use it unless i am zoning. In our area we either have nice days in the70-80's or it is 95 -110 outside it seems and the equipment rarely runs on low thus making the...
  22. Replies
    17
    Views
    2,295

    Which tstats do you use with simular...

    Which tstats do you use with simular features/touchscreen that you can adjust the temp differential for aux on?
  23. Replies
    16
    Views
    1,456

    X2. The biggest five companies here use this...

    X2. The biggest five companies here use this technique and i know this because i was one of them 6 years ago. I was specifically hired because of my sales skills more than tech skills. Thats why they...
  24. Answered above but here it is again. No, not...

    Answered above but here it is again.

    No, not required in our area and all the homes that did have HRV’s installed are either removed or turned off. We have a new law that requires whole house...
  25. Replies
    14
    Views
    1,122

    I have installed 100's of the value classic and...

    I have installed 100's of the value classic and prestige and can tell you that the 15 seer value is one of the quietest quality low cost condensers on the market. That being said i install the...