Search:

Type: Posts; User: schr8er

Page 1 of 3 1 2 3

Search: Search took 0.00 seconds.

  1. Replies
    8
    Views
    2,029

    Steam-Cleaning Coils?

    What's the general consensus around here about using a small resi-grade steam cleaner to clean evap coils? Is there a consensus?

    I've never done it on an in-place coil, but the Boss seems to...
  2. Replies
    21
    Views
    3,804

    Yeah that sucks. My boss would take my pinky...

    Yeah that sucks. My boss would take my pinky finger as repayment if I did something like that.
  3. Replies
    18
    Views
    4,846

    Have I mentioned lately how much I hate rental...

    Have I mentioned lately how much I hate rental properties? Because I feel like getting some shirts made that say F*** YOUR MAINTENANCE GUY AND HIS STUPID OPINION.
  4. Replies
    18
    Views
    4,846

    Two breakers once upon a time fed two boxes--see...

    Two breakers once upon a time fed two boxes--see the old box?--but they decided to take out about fifty feet of conduit and run both breakers through the same junction. At all times of the day their...
  5. Replies
    17
    Views
    4,085

    Where'd he get the license plates?

    Where'd he get the license plates?
  6. Replies
    18
    Views
    4,846

    Electricians are hilarious

    So this is something I haven't seen before...

    http://i166.photobucket.com/albums/u112/KSkrode/IMAG0258.jpg

    Their electrician apparently forgot which disconnect went where, so he just winged it....
  7. Replies
    6
    Views
    2,109

    Even a hole saw or step drill would have been...

    Even a hole saw or step drill would have been preferable to this, but it looks like he just hit it with a punch or maybe just a screwdriver.

    I know sometimes a lot of these guys have to cut...
  8. Replies
    6
    Views
    2,109

    What's "the right blower motor"?

    http://i166.photobucket.com/albums/u112/KSkrode/IMAG0262.jpg

    I don't know how well y'all can see this, but that is a fan rotor sticking through the panel of an AHU.

    Now, if I'd found this on a...
  9. Replies
    27
    Views
    4,294

    For God's sake don't move to South Texas. I was...

    For God's sake don't move to South Texas. I was in my second interview at a mall in Corpus Christi for a facilities maintenance supervisor position with a specialization in hvac/r for their various...
  10. Replies
    2
    Views
    741

    What did the tech do when the system "tested...

    What did the tech do when the system "tested full"? Did he just slap the gauges on and call it good? At any rate, with all that rattling around it probably won't be "full" for very long.

    If it's...
  11. Replies
    34
    Views
    10,035

    I started out in a machine shop assembling...

    I started out in a machine shop assembling sensors and controls for drill collars and other expensive but really boring things for the oil field. We were always having mechanical trouble with the...
  12. Replies
    36
    Views
    3,436

    Ohm the fan to ground and find out. How does the...

    Ohm the fan to ground and find out. How does the compressor affect the fan operation?
  13. Replies
    14
    Views
    2,201

    Around here, al/cu coils go for about $2.50/lb. I...

    Around here, al/cu coils go for about $2.50/lb. I got the old coil as partial payment. :whistle:
  14. Replies
    14
    Views
    2,201

    The thing is, the a/c guy is the same one who...

    The thing is, the a/c guy is the same one who diagnosed the ruined coil in the first place. Not that it was hard to figure out, what with the huge holes in the coil and the smell of oil everywhere,...
  15. Replies
    14
    Views
    2,201

    Performance improved almost as soon as I took the...

    Performance improved almost as soon as I took the panel off.

    I put in a new filter box under the blower, and that was as much as they wanted to pay me for, so I called it then. I'm a little...
  16. Replies
    34
    Views
    3,376

    Water in the day, beer at night. You know,...

    Water in the day, beer at night.

    You know, for a day-to-day life that involves baking in a 130* attic and frying in the 108* sun for half the year, there sure are a lot of fat techs in Texas.
  17. Replies
    14
    Views
    2,201

    So, this is the old coil... ...

    So, this is the old coil...

    http://i166.photobucket.com/albums/u112/KSkrode/IMAG0242.jpg
  18. Replies
    14
    Views
    2,201

    Mysterious air-flow problem

    "I had my a/c guy put in a new coil a few weeks ago, but now the apartment's not getting any air."

    http://i166.photobucket.com/albums/u112/KSkrode/IMAG0241.jpg

    :censored:
  19. It was me. Sorry.

    It was me. Sorry.
  20. Replies
    3
    Views
    696

    That is the new PS90 Flaming Caliper head from...

    That is the new PS90 Flaming Caliper head from Goss. It makes diametric measurements so much easier by destroying whatever you're measuring with fire.

    Seriously, the only dual-tips I've seen like...
  21. Replies
    14
    Views
    1,078

    All that Super Seal seems to do is cost too much...

    All that Super Seal seems to do is cost too much and smell weird. I've never seen it actually stop a leak. Then again I've never seen it kill a compressor, at least not in any obvious way.
  22. Replies
    14
    Views
    1,078

    You might want to consider adding tertiary and...

    You might want to consider adding tertiary and quaternary filters, for added filtering power.
  23. Thread: Cfm

    by schr8er
    Replies
    15
    Views
    1,855

    The usual rule-of-thumb is 400 square feet per 1...

    The usual rule-of-thumb is 400 square feet per 1 ton of cooling, but there are other factors. For your region and general temps it's about 1.5 tons for 600-1000 sqft. If the buildings are...
  24. Thread: Cfm

    by schr8er
    Replies
    15
    Views
    1,855

    What size HVAC units are we talking about here? I...

    What size HVAC units are we talking about here? I had a similar problem with some new townhouses not long ago, where the downstairs would cool off just fine, while the upstairs roasted. It turned out...
  25. Thread: Cfm

    by schr8er
    Replies
    15
    Views
    1,855

    Well, no, obviously. Just that there are other...

    Well, no, obviously. Just that there are other factors to consider before worrying about CFM in an apartment.
Results 1 to 25 of 53
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event