Search:

Type: Posts; User: rtufixer

Search: Search took 0.00 seconds.

  1. Replies
    43
    Views
    1,037

    ok no cracks. But answer my question did you...

    ok no cracks. But answer my question did you look? Finding the crack to the right after you pull the ind mtr looking inside the collector box to the right, sometimes is hard to see if you dont know...
  2. Replies
    43
    Views
    1,037

    have you pulled the inducer mtr and looked at the...

    have you pulled the inducer mtr and looked at the plastic transition to see if its cracked? after you pull the inducer mtr take a mirror and good flashlight and look all the way to the right in the...
  3. Replies
    10
    Views
    885

    Yup happened to me last week. I didnt even use...

    Yup happened to me last week. I didnt even use them. Screen looked like that sitting in a hot van. To many problems gonna get me some ak900s.:gah:
  4. Thread: Lost

    by rtufixer
    Replies
    44
    Views
    3,737

    piston put in backwards and possible overcharge

    piston put in backwards and possible overcharge
  5. Replies
    18
    Views
    1,494

    Johnb01y sounds like we work at the same place....

    Johnb01y sounds like we work at the same place. You work in Illinois
  6. I was suppose to work but they gave me a choice...

    I was suppose to work but they gave me a choice stand by or stand down.
  7. Thread: Testo gauges.

    by rtufixer
    Replies
    24
    Views
    3,368

    Dont waste your time or money one of the worst...

    Dont waste your time or money one of the worst manifolds i have owned. On my second set and getting ready to send this set back.
  8. Replies
    69
    Views
    9,809

    fieldpiece sc56 online for 177. its my primary...

    fieldpiece sc56 online for 177. its my primary meter
  9. Replies
    1
    Views
    430

    need some info

    I received a c/u new in the box never opened. Sears unit mod# 768 81 6041
    Ser # 2001 11 3942. I would like to know what tonnage this thing is or any info possible. Thanks in advance.
  10. Tomato juice get the big cans of this stuff and...

    Tomato juice get the big cans of this stuff and massingill. Got 2 labs and keep this on hand. Best remedy I've come across yet
  11. Replies
    9
    Views
    8,960

    I hope you are using this .380 for target...

    I hope you are using this .380 for target practice and not using it for personal defense JMHO.
  12. Replies
    6
    Views
    949

    Oh I wouldn't reuse anything on this piece of...

    Oh I wouldn't reuse anything on this piece of equipment. New cased coil absoulutely and everything back to the c/u
  13. Replies
    6
    Views
    949

    Thanks

    Baldloonie, thanks for the reply. A definate relic for sure. Was just trying to replace with same size without doing a calc. :)
  14. Replies
    6
    Views
    949

    Anyone hear of this make?

    Heatwave model CL 361 serial 60403505143. Anyone have any info on this?
    C/U died, Older couple limited budget just want to replace with same size unit.The H/O said worked great when it was running....
Results 1 to 14 of 30

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine