  1. Replies
    19
    Views
    2,199

    man i have the same problem,been working on...

    man i have the same problem,been working on carrier 27ton,pakage unit.did everything you did and then some, goin back tomorrow to take a wire and poke it around the inside of the manifold to knock...
  2. Replies
    4
    Views
    718

    thanks i was told by tech from carrier that there...

    thanks i was told by tech from carrier that there is something either in the manifold,are the burners that could be preventing the gas from comming out like spiders etc. I took apart manifold and...
  3. Replies
    4
    Views
    718

    heating problem

    Have a carrier model#48djd028,problem was burners would come on for about 1min then shut off.I noticed middle burner had fire lifting from the end,wire hanging over manifold would sense the heat and...
  4. Replies
    1
    Views
    392

    carrier 27 ton

    went on call for no heat.when i checked out the unit burners came on for about 60 seconds then shut off,after that the burners wouldn't come on anymore.most of my experience is in commercial...
  5. Replies
    4
    Views
    424

    Yes I have applied and yes I am a...

    Yes I have applied and yes I am a professional....wasn't sure where to post.

    I submitted my licensing info and other info requested.

    Thank you!
  6. Replies
    4
    Views
    424

    Aireflo condensor question

    After servicing unit I put the capacitor back in unit and it sparked and then the compressor would not come on but the outdoor fan did start. Is there an internal overload protection that may have...
  7. Replies
    15
    Views
    909

    That is for your secondary drain u can unscrew it...

    That is for your secondary drain u can unscrew it and run pvc into your drain. Your secondary is if your primary drain gets clogged.
  8. I haven't read all the responses but double check...

    I haven't read all the responses but double check the filter isn't clogged it may be as simple as that b/c the air isn't coming accross the coil.
  9. Replies
    8
    Views
    2,205

    I also suggest looking into the tax credit...

    I also suggest looking into the tax credit .....it may be worth it to get the better unit if you can offset the price.
  10. Replies
    48
    Views
    6,104

    Rheem is a good product because they last a long...

    Rheem is a good product because they last a long time in my opinion.
  11. Replies
    14
    Views
    1,682

    They are pretty much the same.....I'd also go...

    They are pretty much the same.....I'd also go with who you thought would do the better job.
  12. Thread: sizing duct?

    by Erik HVAC
    Replies
    2
    Views
    383

    Use a ductulator...not sure I understand your ?

    Use a ductulator...not sure I understand your ?
  13. Replies
    3
    Views
    484

    I agree with Dan you should never use screws in a...

    I agree with Dan you should never use screws in a dryer ducting .
  14. Replies
    13
    Views
    2,741

    I prefer Rheem because I believe its a better...

    I prefer Rheem because I believe its a better unit just based on my opinion on what I see out there.
  15. Replies
    219
    Views
    21,594

    I think Goodman is an inexpensive unit to...

    I think Goodman is an inexpensive unit to purchase but i also agree that there is very little support for us contractors. If I was installing a unit in my home I would go with American Std.
  16. This is a lot of work....it is going to cost...

    This is a lot of work....it is going to cost quite a bit. Are you doing this for looks or function?
  17. Replies
    5
    Views
    627

    Beenthere...I agree....I am in the trade and will...

    Beenthere...I agree....I am in the trade and will get my post to 15 and submit app...thanks I think this is a good practice!

    Dan....I looked at the furnace controll board couldn't find any relays...
  18. Replies
    42
    Views
    2,759

    I agree the 41*F is a very low supply temp......

    I agree the 41*F is a very low supply temp......
  19. Replies
    5
    Views
    627

    trouble shooting goodman 4 ton

    i was looking at this 4 ton goodman split system.indoor and outdoor fans come on but no compressor, when i got there it sounded like the compressor was trying to start but it never did come...
  20. Replies
    11
    Views
    659

    How are they generally designed to work are they...

    How are they generally designed to work are they both suppose to run at the same time? what is happening now is only one is running. The room is 75 degrees and the supply is giving out 63 degrees. I...
  21. Replies
    11
    Views
    659

    Also need a Carrier Pro

    Working on a Carrier right now.....have a 25 ton package unit SAS/Electric that has 2 semi hermetic compressors. Are they supposed to run simultaneously or is one a back up?

    Please help.....