Search:

Type: Posts; User: Pressureman

Page 1 of 3 1 2 3

Search: Search took 0.00 seconds.

  1. Did anyone check the filter?

    Did anyone check the filter?
  2. Replies
    26
    Views
    5,222

    The International Mechanical Code for gypsum...

    The International Mechanical Code for gypsum board plenums shall be limited to systems where air temperatures do not exceed 125F. and the building and mechanical system design conditions are such...
  3. Do a manual J heatload like the other guys have...

    Do a manual J heatload like the other guys have mentioned. This way there is no guessing. First take a static pressure test of the system. Then you can adjust your blower speed to the SP fpr proper...
  4. Replies
    16
    Views
    747

    I agree!

    I agree!
  5. Replies
    24
    Views
    1,201

    Here we go! I'm sure I'm going to step on some...

    Here we go! I'm sure I'm going to step on some toes. Most of your Home Warranty Companies hire the companies who provide the cheapest labor. The technicians really don't have the experience or work...
  6. Holly, get some referrals from your friends and...

    Holly, get some referrals from your friends and family. Remember the government is giving you a tax rebate of $1500.00 and your local utility company may be given a rebate too on 16 Seer or better...
  7. Replies
    6
    Views
    505

    In today's market 13 Seer equipment is generally...

    In today's market 13 Seer equipment is generally pretty well. I always replace the copper line set if it is available to r/r. If not a good rx-11 flush with a nitrogen purge will clean it for R-410-A.
  8. Never used it. The guys from the distributor...

    Never used it. The guys from the distributor swear buy it, then again , they are trying to sell it. Their salesman advised to use the moisture removal kit too. Your right it could clog up the...
  9. Replies
    16
    Views
    2,431

    If they OVERSIZED the system, it will cut on and...

    If they OVERSIZED the system, it will cut on and then cut right off but the interval between cutting ON the first time and cutting ON the second time in any case will be dependent on how fast the...
  10. Hope this leak helps you out!...

    Hope this leak helps you out!
    http://www.fcs.uga.edu/pubs/current/B924.html
  11. Replies
    24
    Views
    1,201

    He probably didn't install a new filter-drier...

    He probably didn't install a new filter-drier either. That is AC 101, always pull a 500 micron vacuum and install a new filter-drier.
    Next question; was the previous compressor a...
  12. Replies
    22
    Views
    3,480

    I used the superboost in tha past and recently...

    I used the superboost in tha past and recently had a thread on a brand new matched unit not starting in 97F ambient temperatures. Convinced on using the hard start kit and had no problems. HSK is...
  13. Replies
    17
    Views
    1,752

    Measured THE 5/40MFD, 370v and the reading came...

    Measured THE 5/40MFD, 370v and the reading came up 37.7. Though that was pretty weak for a brand new capacitor, That is why I installed the 5/45mfd 370v
  14. Replies
    17
    Views
    1,752

    Replaced the supco superboost with the hard start...

    Replaced the supco superboost with the hard start kit. Cycled the system 3 times with 5 minute intervals and system started everytime. You made me a firm believer now Kevin. :bsing: Gave the spare...
  15. Replies
    17
    Views
    1,752

    Amp draw and voltage are ok when compressor is...

    Amp draw and voltage are ok when compressor is running. Compressor doesn't even try to start when system calls for cooling. I will check internal overload tomorrow to see if it is open. I...
  16. Replies
    4
    Views
    2,927

    Here is a link that will answer your question!...

    Here is a link that will answer your question!
    http://highperformancehvac.com/hvac-technical-information/146-hvac-ecm-blower-motors-electronically-commutated-motor
  17. Replies
    17
    Views
    1,752

    Has anyone else had this problem with...

    Has anyone else had this problem with York/Coleman compressors?
  18. Replies
    17
    Views
    1,752

    compressor not starting

    Installed a new Coleman 3 ton, 410-A condenser with A-coil and TXV valve. System starting up fine after installation and adjusted subcool to 10F. Customer calls next day and says it is not working...
  19. Replies
    382
    Views
    18,922

    The Eagles will play those Benncool Patriots in...

    The Eagles will play those Benncool Patriots in the Super Bowl too.............I Hope!
  20. Replies
    382
    Views
    18,922

    Dave, I was sober and still couldn't find anyone....

    Dave, I was sober and still couldn't find anyone. I know who you found and hooked up with!
  21. Replies
    39
    Views
    6,054

    Where's the beer Don? When you see knuckleheads...

    Where's the beer Don? When you see knuckleheads like MWT, you hope he doesn't breed and pass the seed! You know these guys are out there, they supply the humor and give good articles for Dateline.
  22. Replies
    4,843
    Views
    293,918

    Robin doesn't have a sex life, unless you count...

    Robin doesn't have a sex life, unless you count his Goodman blow up doll. To keep with the 9mm theme: He gets a real bang out of it.
  23. Replies
    4,843
    Views
    293,918

    BAMACRACKER isn't original, he's a copycat artist

    BAMACRACKER isn't original, he's a copycat artist
  24. Replies
    4,843
    Views
    293,918

    tv thirty years ago hosted by Bud collier..

    tv thirty years ago hosted by Bud collier..
  25. Replies
    4,843
    Views
    293,918

    was on

    was on
Results 1 to 25 of 55
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event