  1. What were your pressures? Air cooled? Cycling...

    What were your pressures? Air cooled? Cycling cond fan? Headmaster?

    Head pressure change? We're you measuring at the comp leads or breaker?
  2. Replies
    6
    Views
    652

    Agree

    Agree
  3. Replies
    54
    Views
    3,304

    You are reading a voltage drop across a load like...

    You are reading a voltage drop across a load like a CCH, wired to line side of contactor. Meter making the circuit, or grounded side of control transformer.
  4. Replies
    10
    Views
    1,293

    Old rule of thumb! RA=, 1 sq ft/ton@400cfm/ton

    Old rule of thumb! RA=, 1 sq ft/ton@400cfm/ton
  5. Replies
    42
    Views
    2,407

    Nail head, meet hammer, ;-)

    Nail head, meet hammer, ;-)
  6. Replies
    35
    Views
    2,174

    Thought we were talking a/c, my bad.

    Thought we were talking a/c, my bad.
  7. Replies
    35
    Views
    2,174

    Remember, more moisture removal=less dry blub...

    Remember, more moisture removal=less dry blub temp split. (latent vs sensible stuff)

    That said, generally, slightly low sub cooling and slightly high superheat
    = slightly low freon. Ya, need wet...
  8. Replies
    35
    Views
    2,174

    Does not compute........ Adding heat to evap...

    Does not compute........ Adding heat to evap increases subcooling?
  9. Replies
    42
    Views
    2,407

    newbie here, common suction? How is the oil...

    newbie here, common suction? How is the oil separator piped and is the oil pressure switch wired correctly? Unloading? Staged? Pump down or selinoid drop? Just thinking out loud.
  10. Manufactures could care less how hard it is for...

    Manufactures could care less how hard it is for you to get that info. They would rather you sell a unit.

    Careers are made at the factory level by saving a nickel per unit.

    Another question,...
  11. Replies
    34
    Views
    3,685

    high superheat an low SC,,, add two lbs and get...

    high superheat an low SC,,, add two lbs and get back to us. Remember a txv is a constatant superheat device, if you add freon and the SH starts going down, you were flashing in the LL . 40 ft is...
  12. Thread: AC Tune Up

    by Senior1
    Replies
    123
    Views
    6,226

    feast and famine, nature of the beast, did it for...

    feast and famine, nature of the beast, did it for decades, save in the summer, hunt n fish in the spring fall.

    We even hade one tech that would go to job sites and let freon out systems so he...
  13. Walmart window unit in the bedroom is your...

    Walmart window unit in the bedroom is your friend. I keep an old one in the garage, same price as putting wifey up in a motel for one night.
  14. Replies
    15
    Views
    1,689

    Hygroscopic =hyDroscopic, damn computer!

    Hygroscopic =hyDroscopic, damn computer!
  15. Replies
    15
    Views
    1,689

    Which is the reason I recommend HOs that have a...

    Which is the reason I recommend HOs that have a good r22 system keep them. POE are bad juju with moisture. Did anyone mention POEs are 5 times more hygroscopic as mineral oil. (or was that 10 times)
  16. Replies
    27
    Views
    1,517

    You are correct, same in the south. Clean the...

    You are correct, same in the south.

    Clean the cond/evap/blower wheel of an old system, you just saved the same amount as new system. (all else being same, correct charge, air flow,etc.)

    I have...
  17. Replies
    16
    Views
    1,193

    LOL,,that made me laugh, I remember a GE RTU,...

    LOL,,that made me laugh, I remember a GE RTU, about 50 ton HP in the 80's or so, opened the panel and all black wires with 30 relays:gah:
  18. Thread: AC Tune Up

    by Senior1
    Replies
    123
    Views
    6,226

    Yep, big company I worked for had high school...

    Yep, big company I worked for had high school kids doing PMs, and polishing the OD unit so it looked like they did something. Old people, I do many for free on my time.
  19. Thread: AC Tune Up

    by Senior1
    Replies
    123
    Views
    6,226

    Heating,,, gas,,,,PM? Yes, Have a good night ;-)

    Heating,,, gas,,,,PM? Yes, Have a good night ;-)
  20. Thread: AC Tune Up

    by Senior1
    Replies
    123
    Views
    6,226

    Delta t CHANGE on a known working system is good...

    Delta t CHANGE on a known working system is good info for the home owner to monitor THEIR system, any change, call me.

    The problem is we techs have been pushed to SELL, SELL,SELL! The high seller...
  21. Replies
    16
    Views
    1,051

    LOL,,, I have seen leaving the txv bulb hanging...

    LOL,,, I have seen leaving the txv bulb hanging out in the attic considered a fix by some:gah:
  22. Thread: AC Tune Up

    by Senior1
    Replies
    123
    Views
    6,226

    Forgot to add, I have seen just as many new...

    Forgot to add, I have seen just as many new system failures as old.
  23. Thread: AC Tune Up

    by Senior1
    Replies
    123
    Views
    6,226

    You just stated the problem, most RESIDENTIAL...

    You just stated the problem, most RESIDENTIAL PM's are for cash flow only. I'm sorry to jump in late, but I agree with Flash, I also have over 20 yrs exp.

    If you have an old draft type gas...
  24. Replies
    25
    Views
    2,252

    Heat rise is good for ele heat fan coils except...

    Heat rise is good for ele heat fan coils except in the summer. If its 95 outside and you are troubleshooting, last I want to do is heat the customers already hot house up more. I have a electronic...
  25. Replies
    21
    Views
    1,209

    Carrier heating check chart, model will change...

    Carrier heating check chart, model will change info of course.

    http://www.xpedio.carrier.com/idc/groups/public/documents/techlit/38ydb-1xa.pdf


    Ps, read small print