    Yes sir keep us posted

    Yes sir keep us posted
  2. Replies
    18
    Views
    337

    If the powerhead has been changed, compressors...

    If the powerhead has been changed, compressors have been changed there have been a lot of hands in the system. I would start by pulling the charge and seeing if you come up short. Then you have a...
  3. Replies
    29
    Views
    2,320

    Thank you, ive had guys argue about that on here....

    Thank you, ive had guys argue about that on here. They will say it states it in the installation manual. Well yes it does but it states that the coil is a listed section of heat pump also, and if...
  4. Replies
    18
    Views
    337

    What is your Sh Sc With one compressor running?...

    What is your Sh Sc With one compressor running? Is your sight glass clear? This is r-22? Seems like it might be low on refrigerant too me.
  5. Replies
    18
    Views
    337

    It wont run long enough with both compressor...

    It wont run long enough with both compressor running to get SH SC.
  6. Replies
    18
    Views
    337

    What is your return water temp? Do you have...

    What is your return water temp? Do you have enough load in the building to keep both compressprs in tandem running? If your return water is not high enough, i believe it will run one compressor in...
  7. Replies
    2
    Views
    196

    10-4 Thank you

    10-4 Thank you
  8. Replies
    2
    Views
    196

    looking to relocate to north Georgia

    well guys I am looking to relocate to outside of Atlanta, Athens, or possibly Chattanooga, TN. I am looking for any advice on any good commercial company to work for around these areas, and any...
  9. Replies
    6
    Views
    250

    Sure sounds like a cracked solder joint or...

    Sure sounds like a cracked solder joint or something to that effect. Had one doing that one time where the R wire was cracked and it would go off on anti short cycle when i touched around it
  10. Replies
    3
    Views
    1,330

    Lol. You would have to know where they are also

    Lol. You would have to know where they are also
  11. Thread: One I did...

    by david912
    Replies
    20
    Views
    2,018

    Lol. Not half bad

    Lol. Not half bad
  12. Replies
    3
    Views
    1,330

    I would like to strangle him!

    493431
    these are two 10 ton AH, caint get to the belt, controls or anything on this side of the unit

    493441
    both AH are twinned and share the same (Ductboard) ductwork

    493451
    This is the...
  13. Replies
    9
    Views
    547

    X2 liquid back to the compressor

    X2 liquid back to the compressor
  14. Thread: bullet

    by david912
    Replies
    5
    Views
    308

    Had a helper hook up mine a while back and...

    Had a helper hook up mine a while back and somehow it had pressure on the system and he must have been looking at the exaust port lol. There was so much pressure there was oil dripping off the...
  15. Thread: NO!

    by david912
    Replies
    64
    Views
    9,534

    No problem, and definatly no broad...

    No problem, and definatly no broad generalizations. There are definatly some smart guys in plant operations
  16. Replies
    19
    Views
    818

    ill be dang. wonder what else forbidden :grin2:

    ill be dang. wonder what else forbidden :grin2:
  17. Replies
    19
    Views
    818

    ********

    ********
  18. Replies
    30
    Views
    1,733

    Pretty sure if you added 3 lbs and where only...

    Pretty sure if you added 3 lbs and where only able to recover under 2 lbs, if indeed there was a leak in the condenser and you lost over a pound inbetween the time you charged it and the time you...
  19. Replies
    26
    Views
    1,208

    3 ton requires around 432 sq in. Of return, a...

    3 ton requires around 432 sq in. Of return, a 20x20 is 400. Not much off. And when you took the coil door off, you were actually bypassing the evap coil causing the frost issue an psi drop, ...
  20. Good eye. The ol helper, that got corrected...

    Good eye. The ol helper, that got corrected when i ran the emt for the receptacle
  21. In the installation instructions, it notes; if...

    In the installation instructions, it notes; if cooling coil is negative pressure (blower pullls air though coil) drains must be trapped, and vented. Then it has the illustration for trap...
  22. I see where your coming from. Really dosent...

    I see where your coming from. Really dosent require either, this is not a negative psi system, and the gas line is a vertical run although it would be good to have for moisture purposes, ill agree...
  23. Mabey some foam tape or clear silicone in between...

    Mabey some foam tape or clear silicone in between coil and furnace, and filterbase and furnace. Rather than aluminum tape, X2 on the power cord and the flex on that far of a run dosent look the...
  24. lol Dang pics turned out huge. had to make some...

    lol Dang pics turned out huge. had to make some adjustments
  25. switch from electric to gas furnace W/lineset

    476311476321
    476331

    There used to be an old amana air handler in this location pic is not the best, no heat pump just straight electric heat. Had to drop return plenum down about 2 feet to...