Search:

Type: Posts; User: Freezeking2000

Page 1 of 20 1 2 3 4

Search: Search took 0.04 seconds.

  1. Replies
    27
    Views
    686

    OMG.........get it out of that house with that...

    OMG.........get it out of that house with that kid in it.
  2. Replies
    6
    Views
    353

    how are you going to manage oil return?

    how are you going to manage oil return?
  3. How old is the system. ?

    How old is the system. ?
  4. I rated them based on my experience.

    I rated them based on my experience.
  5. Replies
    6
    Views
    219

    I think Buderus oil is as good as it gets

    I think Buderus oil is as good as it gets
  6. Replies
    6
    Views
    219

    ALL WAY TO BIG! what is the heat loss?

    ALL WAY TO BIG!

    what is the heat loss?
  7. I think your safe with that just make sure your...

    I think your safe with that just make sure your simulating high head while adjusting it. Set them at 180 psig to 125% then when hot and running 280 psig you will trip ol a few times
  8. I would always set the cpr for 120-130% of fla or...

    I would always set the cpr for 120-130% of fla or the box may never pull down if really hot outside. I am talking about 2hp and up systems. Normally no need for a cpr on a small can.

    Brian
  9. I would always set the cpr for 120-130% of fla or...

    I would always set the cpr for 120-130% of fla or the box may never pull down if really hot outside. I am talking about 2hp and up systems. Normally no need for a cpr on a small can.

    Brian
  10. I would always set the cpr for 120-130% of fla or...

    I would always set the cpr for 120-130% of fla or the box may never pull down if really hot outside. I am talking about 2hp and up systems. Normally no need for a cpr on a small can.

    Brian
  11. Commercial Takeoff software whats good?

    I have been looking for some software to help me figure running commercial ductwork.

    Looking for fabrication and installation software to assist in figuring commercial work for 10k-50K SF spaces....
  12. Replies
    8
    Views
    372

    5/16 on a 2.5 ton should be ok Sent from my...

    5/16 on a 2.5 ton should be ok

    Sent from my XT1080 using Tapatalk
  13. 2x4 to the ground as a temp support should work...

    2x4 to the ground as a temp support should work for blower removal.
  14. Replies
    6
    Views
    398

    I do believe you have a nice quiet furnace and I...

    I do believe you have a nice quiet furnace and I do not know where you are going with this?

    I do believe this was Rheems best in the day.
  15. Replies
    8
    Views
    1,690

    Free lifetime warranty as long as you can wait...

    Free lifetime warranty as long as you can wait weeks for a service call.

    Sent from my XT1080 using Tapatalk
  16. Greenspeed

    Also keep in mind the Greenspeed will spend very little time on high making the duct size a non issue.
  17. What does the selling contractor say. Maybe the...

    What does the selling contractor say. Maybe the unit had no gas from the factory.

    The quote normally quotes all equipment and installation for a price including a 1-2 year parts and labor plus 7...
  18. With the more advanced I comfort system the...

    With the more advanced I comfort system the system will most times tell you about a problem before you know it or damage is done to the system. The 2 units really cant be compared there is no unit...
  19. Who's paying to clean seawater heat exchanger ...

    Who's paying to clean seawater heat exchanger

    Sent from my XT1080 using Tapatalk
  20. Call the manufacturer of the unit. Gravity coils...

    Call the manufacturer of the unit. Gravity coils with no fan need long defrost cycles


    Sent from my XT1080 using Tapatalk
  21. Replies
    30
    Views
    1,571

    Most likely it is running great. Most likely very...

    Most likely it is running great. Most likely very little non condensables as I am sure it was still venting off from the oil as he was brazing it up.

    I would not bother with it.
  22. Replies
    15
    Views
    616

    Pressure drop does not come into play with...

    Pressure drop does not come into play with distributors. You must use an externally equalized valve in this application.

    Sent from my XT1080 using Tapatalk
  23. Replies
    7
    Views
    348

    We just had our first one. Same plug. Sent...

    We just had our first one. Same plug.

    Sent from my XT1080 using Tapatalk
  24. Replies
    7
    Views
    348

    Great furnace and we have not had a leak on one...

    Great furnace and we have not had a leak on one unit we have installed. He must be missing something that has a crack or something like that.