    Yes, have a duct blaster test done. Here ya go....

    Yes, have a duct blaster test done. Here ya go. ...
  2. Replies
    10
    Views
    556

    Check out ACCA's " Bobs House" written by ACCA...

    Check out ACCA's " Bobs House" written by ACCA instructor Wes Davis. Wes explains that installing a supply register in " any room I can walk in " DOES NOT always make good sense. In some regions...
  3. Replies
    13
    Views
    657

    That's a good start. But check this out...

    That's a good start. But check this out also.http://www.acca.org/homes/
  4. Replies
    27
    Views
    852

    In a nutshell no. Same unit without the fancy...

    In a nutshell no. Same unit without the fancy top. Some say it will collect leaves, I say it will have better air flow in restricted areas
  5. The future in this industry is with VRV/VRF...

    The future in this industry is with VRV/VRF systems not single systems with zone dampers.
  6. Replies
    13
    Views
    657

    So have any improvements been done on the home (...

    So have any improvements been done on the home ( windows, insulation, air sealing, duct sealing and so on )? If so the manual J that in reality was probably never done is useless!



    That is...
  7. Replies
    13
    Views
    657

    Well has anyone done a manual J on your home? ...

    Well has anyone done a manual J on your home? How about checked the TESP ( total external static pressure) on your duct system? How about a ductblaster for duct leakage?
    And no I would not put a...
  8. Replies
    13
    Views
    657

    I would concern myself more about the installing...

    I would concern myself more about the installing contractor than the brand!
  9. Replies
    27
    Views
    852

    Joe, I think you would find that lunch very...

    Joe, I think you would find that lunch very interesting and worthwhile.
  10. Replies
    27
    Views
    852

    Joe, Daikin already has a VS split A/C ( came out...

    Joe, Daikin already has a VS split A/C ( came out about 45 days ago) on the market with there VS Heat pump to follow in the fall. But I don't think they have plans to put the Goodman name on it...
  11. Replies
    27
    Views
    852

    IMHO you will not be seeing any high end Daikin...

    IMHO you will not be seeing any high end Daikin product with the Goodman name anytime soon.
  12. Replies
    12
    Views
    500

    Here ya go. Outdoor Model 4TWV8037A1 ...

    Here ya go.

    Outdoor Model
    4TWV8037A1

    Indoor Model
    TAM8C0C42V31
    18 SEER
    ARIREF
    7043213
  13. Replies
    12
    Views
    500

    You might consider the XV18 in lieu of the XL18i....

    You might consider the XV18 in lieu of the XL18i. Ask your contractor about it.
  14. Thread: Goodman

    by jimj
    Replies
    16
    Views
    614

    Yup I agree. If it went from working to not...

    Yup I agree. If it went from working to not working over night and no leak was repaired, he will be back.
  15. Thread: Goodman

    by jimj
    Replies
    16
    Views
    614

    Why would he pay the installer for a repair on a...

    Why would he pay the installer for a repair on a brand new system? Or did he only do the install and did not furnish the unit?
  16. Replies
    46
    Views
    962

    Google " Bigger is not better". And " if bigger...

    Google " Bigger is not better". And " if bigger is not better what is" by John Proctor I think you will find your answer!

    Have you seen any setback thermostats lately with the " energy star"...
  17. Replies
    46
    Views
    962

    I agree! Put in a VS system of proper size and...

    I agree! Put in a VS system of proper size and forget about it.
  18. And no you don't have a low airflow issue.

    And no you don't have a low airflow issue.
  19. Your target TD is 14.4* you have 14* ( your IDWB...

    Your target TD is 14.4* you have 14* ( your IDWB is 71*) your subcooling is 10* you have 9* your Superheat is 10* your target is 12*. Sooooo whats your problem?

    Where did you measure your system...
  20. If his numbers are correct and its R410a its...

    If his numbers are correct and its R410a its about 61*
  21. Replies
    3
    Views
    298

    Hopefully you are confused about this part as I...

    Hopefully you are confused about this part as I doubt this is the case.

    As far as Aeroseal its a great process, go for it!
  22. Replies
    8
    Views
    390

    Have a duct blaster test done and you will know...

    Have a duct blaster test done and you will know what your facing. And yes that is ugly!
  23. Replies
    20
    Views
    949

    Don't forget to register unit for full...

    Don't forget to register unit for full manufacturer warranty. Opps that right internet units don't have any warranty!
  24. Replies
    768
    Views
    53,089

    That would be nice as that's exactly what I...

    That would be nice as that's exactly what I ordered!
  25. Replies
    28
    Views
    1,786

    It would be worth spending a few more dollars and...

    It would be worth spending a few more dollars and take advantage of the full capabilities of your system by having your contractor install the communicating controller. Not to mention it will likely...