  1. Your making a straw man argument. Not all 2...

    Your making a straw man argument. Not all 2 stage furnaces, installed with single stage t-stats, work the way that you described. Upstaging is not simply based by timing. It is logic based.
  2. Replies
    16
    Views
    534

    You are under firing a "little bit", but that is...

    You are under firing a "little bit", but that is not your problem. Nothing that you posted has me suspecting the gas valve is causing your problem. I would not go as far as to say that the tech...
  3. Replies
    2
    Views
    307

    Yes you will have more heat exfiltration on...

    Yes you will have more heat exfiltration on larger duct work, but that is not going to amount to anything significant. The duct work needs to be sized to move enough air for hi fire.
  4. What's the model no of the furnace? Some 2 stage...

    What's the model no of the furnace? Some 2 stage furnaces can be installed with a 1 stage t-stat and still operate as a 2 stage furnace if w1 and w2 are jumped together. When the control receives a...
  5. Replies
    16
    Views
    534

    He was checking the outlet pressure. What was...

    He was checking the outlet pressure. What was the inlet pressure both with the furnace running and with it off? Obviously your outlet pressure cannot be greater than the inlet pressured. BTW...
  6. Replies
    16
    Views
    534

    The Honeywell part is a low gas pressure switch. ...

    The Honeywell part is a low gas pressure switch. It's purpose is to keep the gas valve from opening if the inlet pressure is not hi enough to be safe.

    You have the wrong gas valve for your...
  7. As if I needed another reason not to work on oil...

    As if I needed another reason not to work on oil burners :gah:
  8. Thread: Home advisor

    by m singer
    Replies
    8
    Views
    645

    I used them a couple of years ago. Won't use...

    I used them a couple of years ago. Won't use them ever again.
  9. I very much doubt that either the name plate...

    I very much doubt that either the name plate charge is wrong or that you added over the name plate. I suggest "measuring" the air flow before concluding that the hi pressure is due to an over charge.
  10. Is it possible that the compressor is running on...

    Is it possible that the compressor is running on hi while the blower is running on low?
  11. Replies
    26
    Views
    1,065

    Let the recovery machine pull the system down to...

    Let the recovery machine pull the system down to at least 10" vacuum. Heat the compressor, if needed, to speed up the process. Break the vacuum with nitrogen. Never open a system under a vacuum...
  12. Replies
    37
    Views
    1,626

    I have the Milwaukee 12v fuel 1/4 hex driver. It...

    I have the Milwaukee 12v fuel 1/4 hex driver. It has plenty of power and run time for just about anything other than spinning a large uni bit. I do have a 18 volt for use when needed, but for most...
  13. Been using Appion G-5 for a long time. It is the...

    Been using Appion G-5 for a long time. It is the best that I have seen
  14. Replies
    14
    Views
    917

    I agree that it will "help" keep the switch dry. ...

    I agree that it will "help" keep the switch dry. That is the idea behind the bleed orifice that most furnace air pressure switch "already" have. I disagree that it won't effect the vacuum. ...
  15. Replies
    5
    Views
    574

    Describe your evacuation setup. If your hoses...

    Describe your evacuation setup. If your hoses are not isolated from the system there will be in gassing though the hoses, and the deep vacuum will be lost. .
  16. Replies
    29
    Views
    1,589

    How long does the sensor last and how much does...

    How long does the sensor last and how much does it cost to replace the sensor?
  17. Replies
    13
    Views
    1,728

    if set to p1 it will show + or - for P1. If set...

    if set to p1 it will show + or - for P1. If set for P2 it will show + or - for p2. The bottom or differential reading is just the dif. No + or -
  18. Replies
    13
    Views
    1,728

    It is a great tool but the pump starts out at...

    It is a great tool but the pump starts out at several inches of WC witch is too hi for almost all of the testing that we do. It is tedious to get the pump settle down close to the range that you...
  19. Replies
    12
    Views
    880

    Typically ecm draft motors do not have the...

    Typically ecm draft motors do not have the electronics module as part of the motor the way blower motors do.
  20. Replies
    12
    Views
    704

    As long as the replacement coil fits in the...

    As long as the replacement coil fits in the existing AHU and the coil and Condenser are AHRI matched, I don't see a problem with it. Still for only a little more money I'd rather replace the hole...
  21. Replies
    8
    Views
    890

    I had mine for years. It works well for me.

    I had mine for years. It works well for me.
  22. Replies
    22
    Views
    1,984

    That is BS IMO. Hopefully they make it for it in...

    That is BS IMO. Hopefully they make it for it in other ways.
  23. Replies
    25
    Views
    2,537

    I talked with Brenda today about manifold valve...

    I talked with Brenda today about manifold valve leak on my older AK900. I asked if they had the swivel adapters need to use the AK900 with a YJ 41 manifold.

    She said that they did and that they...
  24. Replies
    22
    Views
    1,984

    You can replace the ball valve assembly simply...

    You can replace the ball valve assembly simply unscrewing it and screwing on a replacement, that is sold separately, but you might not save enough money to make it worth it.
  25. Replies
    30
    Views
    2,456

    Yes it is but it is also temperature...

    Yes it is but it is also temperature compensating. I have not used mine at 10*
  26. Replies
    49
    Views
    3,465

    It depends. In some applications the OEM...

    It depends. In some applications the OEM compressor will have unique features that would make using a non OEM compressor risky. I would not replace a scroll with a recip. In other cases it is not...
  27. Replies
    603
    Views
    93,140

    I don't have any b!tches about my AK 900's. ...

    I don't have any b!tches about my AK 900's. Everything that I need with no BS features that I don't need or want to pay for.
  28. Replies
    11
    Views
    1,445

    Actually PVE oil sucks up moisture even faster...

    Actually PVE oil sucks up moisture even faster than POE oil. The difference is that PVE oil will not hydrolyze like POE oil will and that a deep vacuum can remove moisture from PVE oil but not POE...
  29. Thread: Start relay

    by m singer
    Replies
    3
    Views
    456

    https://www.marsdelivers.com/wps/wcm/connect/0f4c2...

    https://www.marsdelivers.com/wps/wcm/connect/0f4c2377-9b43-415c-b2eb-a89019251d2c/Potential+Relay+Xref-98853.pdf?MOD=AJPERES&CONVERT_TO=url&CACHEID=0f4c2377-9b43-415c-b2eb-a89019251d2c
  30. Replies
    18
    Views
    2,010

    I just wear my bifocal eye glasses, but I also...

    I just wear my bifocal eye glasses, but I also use a turbo torch witch is easier on the eyes than oxy/acet.
  31. Replies
    10
    Views
    1,296

    I have ball valves on all hoses and this is what...

    I have ball valves on all hoses and this is what I do in this order.

    1 close hi side ball valve

    2 open manifold valves

    3 remove hi side hose

    4 close low side ball valve and remove...
  32. Replies
    25
    Views
    2,296

    A sling psychrometer may be accurate where you...

    A sling psychrometer may be accurate where you can swing it, but it wont account for heat infiltration of a return duct in a hot attic like an induct psychrometer will. Practically speaking a...
  33. Replies
    54
    Views
    6,720

    It's a male run T like this. Should be able to...

    It's a male run T like this. Should be able to find it a plumbing supply locally or order one on line. I'd suggest you source it locally unless you are sure what size the hole in your particular...
  34. Replies
    54
    Views
    6,720

    http://i286.photobucket.com/albums/ll90/marty3006/...

    http://i286.photobucket.com/albums/ll90/marty3006/FullSizeRender7_zpsrjusz7t7.jpg
  35. Replies
    54
    Views
    6,720

    Very true. I didn't believe it until I tried it....

    Very true. I didn't believe it until I tried it. He is not exaggerating.

    http://i286.photobucket.com/albums/ll90/marty3006/FullSizeRender8_zpsublrcr9s.jpg
  36. Replies
    9
    Views
    1,068

    I used to have one and found it to have problems...

    I used to have one and found it to have problems syching up. It was very frustrating at times. I have a Refco wireless scale now that I like much better. ...
  37. Replies
    35
    Views
    5,966

    I have a couple of AK 900's. They are awesome! ...

    I have a couple of AK 900's. They are awesome! The deal breaker for me with the Fieldpiece SMAN's is the thermocouple pipe clamps. The Thermistor pipe clamps on the DC are way more accurate and...
  38. Replies
    6
    Views
    792

    I have a couple of 3/8 ID YJ hoses. No problems

    I have a couple of 3/8 ID YJ hoses. No problems
  39. Replies
    18
    Views
    2,371

    I have not managed to break anything on either of...

    I have not managed to break anything on either of my AK 900's yet, but that's good to hear.

    Contrast that TIF. I recently had an empty plastic box, for a leak detector, fall 3 feet and land on...
  40. Replies
    25
    Views
    3,113

    I have 3 at the moment. Inficon tek mate that...

    I have 3 at the moment. Inficon tek mate that works great on r-22 but is useless on 410a. A Fieldpiece SRL2K7 that works fair but not very good on r 410 and not nearly as well as the tek mate on...
  41. Replies
    23
    Views
    2,913

    Oh I just saw that you "do" have natural gas. ...

    Oh I just saw that you "do" have natural gas. I'd probably go with gas heat, but that's just a preference. HP's work well here too. You could also go dual fuel for not much more money than...
  42. Replies
    23
    Views
    2,913

    I live and work in the Knoxville, TN area. My...

    I live and work in the Knoxville, TN area. My home, and much of my service area is rural and does not have natural gas. I have an air source HP and it works quite well. No worries heat pumps...
  43. Thread: pay scale

    by m singer
    Replies
    39
    Views
    5,008

    To the OP. I graduated tech school and got my...

    To the OP. I graduated tech school and got my first job in 2003. I started at $12.00/hr, and this was in Knoxville, TN. Not a small town but not a big city either. IMO you are under paid.
  44. Thread: pay scale

    by m singer
    Replies
    39
    Views
    5,008

    On serious accident while working for someone...

    On serious accident while working for someone else and your career is equally over!
  45. Replies
    26
    Views
    3,366

    Yes several times. consider CRT's wear items. ...

    Yes several times. consider CRT's wear items. I always keep spares on hand.
  46. Replies
    2
    Views
    3,379

    Generally speaking, torque specs are for clean...

    Generally speaking, torque specs are for clean dry fasteners unless otherwise specified. Oiling the threads will greatly increase the clamping force any any given torque.
  47. Replies
    3
    Views
    814

    Just re-read the instruction manual and it was a...

    Just re-read the instruction manual and it was a user error issue. Nothing wrong with the Ak's. I must have inadvertently zeroed them to atmosphere in psia mode when I should have zeroed them in...
  48. Replies
    3
    Views
    814

    The AK's are zeroed to read 0 at atmospheric...

    The AK's are zeroed to read 0 at atmospheric pressure.
  49. Replies
    3
    Views
    814

    Problem with AK 900's

    http://i286.photobucket.com/albums/ll90/marty3006/IMGP3669_zps684e56cf.jpg


    69.5 psig of r 22 should correspond to a saturation temp of 40 degrees F. These saturation temps are about 10 degrees...
  50. Replies
    25
    Views
    3,173

    Last week I used mine to find a r410a leak...

    Last week I used mine to find a r410a leak outdoors on a condenser. It was a good size leak though. I also though it was a POS when I first started using it but, once I learned the nuances of...